Diagnostic performance of computed tomographic angiography-based planimetry for the assessment of mitral stenosis.

IF 1.5
Philipp Steinhoff, Ramona Schmitt, Derek Hazard, Manuel Hein, Johannes Brado, Hannah Momm, Dirk Westermann, Franz-Josef Neumann, Philipp Breitbart, Philipp Ruile
{"title":"Diagnostic performance of computed tomographic angiography-based planimetry for the assessment of mitral stenosis.","authors":"Philipp Steinhoff, Ramona Schmitt, Derek Hazard, Manuel Hein, Johannes Brado, Hannah Momm, Dirk Westermann, Franz-Josef Neumann, Philipp Breitbart, Philipp Ruile","doi":"10.1007/s10554-026-03803-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Mitral stenosis (MS) remains diagnostically challenging, particularly in degenerative disease, where echocardiographic parameters are often unreliable. Computed tomography (CT) planimetry has been validated for other valvular diseases, but is not established for MS. This study evaluated the feasibility and diagnostic performance of CT planimetry in patients with MS compared with echocardiographic parameters.</p><p><strong>Methods: </strong>We retrospectively analyzed 85 patients (mean age 79 ± 7.8 years, 63.5% female), who underwent ECG-gated cardiac CT within 90 days of a transthoracic echocardiography with a mean mitral transvalvular pressure gradient (MPG) ≥ 5 mmHg between 2019 and 2024. Patients with severe mitral regurgitation, mechanical valves, valve-in-valve procedures, prior edge-to-edge repair, or inadequate image quality were excluded.</p><p><strong>Results: </strong>CT planimetry of mitral valve area (MVA) was feasible and showed high interobserver agreement (intraclass correlation coefficient 0.983, 95% CI 0.960;0.993). CT-derived MVA correlated inversely with MPG (rho - 0.60, 95% CI -0.73;-0.42) and moderately with echocardiographic planimetry (rho 0.58, 95% CI 0.29;0.78), particularly in degenerative and native valve subgroups. Correlations with pressure half-time (PHT)-derived MVA were weak and inconsistent (rho 0.32, 95% CI -0.01;0.60).</p><p><strong>Conclusion: </strong>Computed tomography planimetry showed significant correlations with MPG and echocardiographic planimetry, but not with the indirect estimation of MVA by PHT. It proved to be a feasible and highly reproducible tool for assessing MVA in MS and therefore may serve as a complementary method in cases with inconclusive or technically limited echocardiographic findings.</p>","PeriodicalId":94227,"journal":{"name":"The international journal of cardiovascular imaging","volume":" ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2026-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The international journal of cardiovascular imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10554-026-03803-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Mitral stenosis (MS) remains diagnostically challenging, particularly in degenerative disease, where echocardiographic parameters are often unreliable. Computed tomography (CT) planimetry has been validated for other valvular diseases, but is not established for MS. This study evaluated the feasibility and diagnostic performance of CT planimetry in patients with MS compared with echocardiographic parameters.

Methods: We retrospectively analyzed 85 patients (mean age 79 ± 7.8 years, 63.5% female), who underwent ECG-gated cardiac CT within 90 days of a transthoracic echocardiography with a mean mitral transvalvular pressure gradient (MPG) ≥ 5 mmHg between 2019 and 2024. Patients with severe mitral regurgitation, mechanical valves, valve-in-valve procedures, prior edge-to-edge repair, or inadequate image quality were excluded.

Results: CT planimetry of mitral valve area (MVA) was feasible and showed high interobserver agreement (intraclass correlation coefficient 0.983, 95% CI 0.960;0.993). CT-derived MVA correlated inversely with MPG (rho - 0.60, 95% CI -0.73;-0.42) and moderately with echocardiographic planimetry (rho 0.58, 95% CI 0.29;0.78), particularly in degenerative and native valve subgroups. Correlations with pressure half-time (PHT)-derived MVA were weak and inconsistent (rho 0.32, 95% CI -0.01;0.60).

Conclusion: Computed tomography planimetry showed significant correlations with MPG and echocardiographic planimetry, but not with the indirect estimation of MVA by PHT. It proved to be a feasible and highly reproducible tool for assessing MVA in MS and therefore may serve as a complementary method in cases with inconclusive or technically limited echocardiographic findings.

基于计算机断层血管造影的平面测量对二尖瓣狭窄的诊断价值。
目的:二尖瓣狭窄(MS)的诊断仍然具有挑战性,特别是在退行性疾病中,超声心动图参数往往不可靠。计算机断层扫描(CT)平面测量已被证实用于其他瓣膜疾病,但尚未建立MS。本研究评估了CT平面测量在MS患者中的可行性和诊断性能,并将其与超声心动图参数进行比较。方法:我们回顾性分析了85例患者(平均年龄79±7.8岁,63.5%为女性),这些患者在2019年至2024年间接受经胸超声心动图检查后90天内接受了ecg门控心脏CT检查,平均二尖瓣经瓣压力梯度(MPG)≥5 mmHg。有严重二尖瓣返流、机械瓣膜、瓣内手术、先前边缘到边缘修复或图像质量不佳的患者被排除在外。结果:CT平面测量二尖瓣面积(MVA)是可行的,观察者间一致性高(类内相关系数0.983,95% CI 0.960;0.993)。ct衍生的MVA与MPG呈负相关(rho - 0.60, 95% CI -0.73;-0.42),与超声心动图平面测量呈正相关(rho 0.58, 95% CI 0.29;0.78),特别是在退行性和原生瓣膜亚组中。与压力半时间(PHT)衍生的MVA的相关性较弱且不一致(rho 0.32, 95% CI -0.01;0.60)。结论:计算机断层平面测量与MPG和超声心动图平面测量有显著相关性,但与PHT间接估计MVA无显著相关性。它被证明是一种评估多发性硬化症MVA的可行且高度可重复性的工具,因此可以作为超声心动图结果不确定或技术有限的病例的补充方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书