Cardiac Migration of an Inverted Inferior Vena Cava Filter: Successful Retrieval via a Jugular Loop-Snare Technique.

IF 0.7
Huayu Wang, Yutao Wang, Yan Sun
{"title":"Cardiac Migration of an Inverted Inferior Vena Cava Filter: Successful Retrieval via a Jugular Loop-Snare Technique.","authors":"Huayu Wang, Yutao Wang, Yan Sun","doi":"10.1177/15385744261491449","DOIUrl":null,"url":null,"abstract":"<p><p>This report describes a 67-year-old female with lower extremity deep vein thrombosis who developed right atrial migration of an inverted inferior vena cava (IVC) filter 2 weeks post-implantation. After failed femoral retrieval, the filter was successfully extracted via a simplified jugular loop-snare technique using conventional endovascular equipment. No perioperative complications occurred, and postoperative angiography confirmed IVC patency. Inverted deployment is a preventable cause of life-threatening IVC filter migration, and the jugular loop-snare technique offers a safe, reproducible rescue strategy for such complex cases.</p>","PeriodicalId":94265,"journal":{"name":"Vascular and endovascular surgery","volume":" ","pages":"15385744261491449"},"PeriodicalIF":0.7000,"publicationDate":"2026-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular and endovascular surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15385744261491449","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This report describes a 67-year-old female with lower extremity deep vein thrombosis who developed right atrial migration of an inverted inferior vena cava (IVC) filter 2 weeks post-implantation. After failed femoral retrieval, the filter was successfully extracted via a simplified jugular loop-snare technique using conventional endovascular equipment. No perioperative complications occurred, and postoperative angiography confirmed IVC patency. Inverted deployment is a preventable cause of life-threatening IVC filter migration, and the jugular loop-snare technique offers a safe, reproducible rescue strategy for such complex cases.

下腔静脉内翻滤过器的心脏迁移:通过颈静脉环圈套技术成功取出。
本报告描述了一位67岁女性下肢深静脉血栓患者,在植入下腔静脉(IVC)过滤器2周后发生右心房移位。在股骨取出失败后,使用常规血管内设备通过简化颈静脉环-圈套技术成功取出过滤器。围手术期无并发症发生,术后血管造影证实下腔静脉通畅。内腔静脉滤过器移位是一种可预防的原因,颈静脉环圈套技术为此类复杂病例提供了一种安全、可重复的救援策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书