Echocardiographic Estimation of Pulmonary Artery Wedge Pressure in Advanced Heart Failure: Head-to-Head Comparison Against Right Heart Catheterization.

IF 1.5
Luca Pascalis, Vincenzo Nuzzi, Fulvio Perani, Filippo Bova, Stefano Cannata, Luca Fazzini, Alessandro Lucchino, Aida Piroddi, Manlio Cipriani, Paolo Manca
{"title":"Echocardiographic Estimation of Pulmonary Artery Wedge Pressure in Advanced Heart Failure: Head-to-Head Comparison Against Right Heart Catheterization.","authors":"Luca Pascalis, Vincenzo Nuzzi, Fulvio Perani, Filippo Bova, Stefano Cannata, Luca Fazzini, Alessandro Lucchino, Aida Piroddi, Manlio Cipriani, Paolo Manca","doi":"10.1007/s10554-026-03823-5","DOIUrl":null,"url":null,"abstract":"<p><p>Several equations have been proposed to non-invasively estimate pulmonary artery wedge pressure (PAWP) and have been validated against right heart catheterization (RHC). However, their accuracy in patients with advanced heart failure (AdvHF) remains uncertain. We assessed the agreement between echocardiographic and invasive PAWP measurements at rest and during vasodilator testing. Consecutive patients referred for AdvHF undergoing paired transthoracic echocardiography (TTE) and RHC within 24 hours were prospectively enrolled. Echocardiographic PAWP was calculated with the Nagueh E/e' equation and with the left atrial volume index (LAVi) and mitral E-based equation reported by Lindow (ePAWP-E). Agreement with invasive PAWP was assessed by Spearman correlation and Blant-Altman analysis, and discrimination for elevated PAWP (≥ 15 mmHg) by receiver operating characteristic (ROC) analysis, overall and in the pre-specified subgroup with left atrial volume index (LAVi) < 48 mL/m². In patients undergoing sodium nitroprusside challenge, invasive and echocardiographic PAWP change (ΔPAWP) was analyzed and compared. Of 176 patients enrolled, 172 (mean age was 52.6 ± 12.1 years and 76.2% were males), had an interpretable PAWP and formed the analytic cohort; 77 (44.8%) had PAWP ≥ 15 mmHg. Correlation with invasive PAWP was ρ = 0.452 for Nagueh (n = 148) and ρ = 0.550 for ePAWP-E (n = 156, both p < 0.001), with AUC 0.759 (95% CI 0.677-0.833) and 0.798 (95% CI 0723-0.864). Both equations overestimated invasive PAWP (bias + 3.2 and + 2.6 mmHg) with wide limits of agreement (-13.3 to + 19.7 and - 11.6 to + 16.8 mmHg). In the LAVi < 48 mL/m² subgroup, agreement improved (ρ = 0.496 vs. 0.655; AUC 0.850 and 0.927) and the limits of agreement for ePAWP-E narrowed to - 8.3 to + 10.3 mmHg. During nitroprusside challenge, invasive ΔPAWP was 9.6 ± 7.6 mmHg whereas echocardiographic ΔePAWP was 2.4 ± 5.6 mmHg (Nagueh, n = 33) and 1.5 ± 6.0 mmHg (ePAWP-E, n = 34; both p < 0.001 vs. invasive), with weak Δ correlations (ρ = 0.414 and 0.389). In AdvHF, echocardiographic equations correlate only moderately with invasive PAWP and are not accurate enough for individual-level quantification. The LAVi- and E-based equation performs best and may be used to rule in or rule out elevated filling pressures at rest when the left atrium is not severely dilated. Neither equation tracks the acute PAWP changes induced by vasodilator challenge, so RHC remains indispensable whenever the clinical question is dynamic.</p>","PeriodicalId":94227,"journal":{"name":"The international journal of cardiovascular imaging","volume":" ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2026-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The international journal of cardiovascular imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10554-026-03823-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Several equations have been proposed to non-invasively estimate pulmonary artery wedge pressure (PAWP) and have been validated against right heart catheterization (RHC). However, their accuracy in patients with advanced heart failure (AdvHF) remains uncertain. We assessed the agreement between echocardiographic and invasive PAWP measurements at rest and during vasodilator testing. Consecutive patients referred for AdvHF undergoing paired transthoracic echocardiography (TTE) and RHC within 24 hours were prospectively enrolled. Echocardiographic PAWP was calculated with the Nagueh E/e' equation and with the left atrial volume index (LAVi) and mitral E-based equation reported by Lindow (ePAWP-E). Agreement with invasive PAWP was assessed by Spearman correlation and Blant-Altman analysis, and discrimination for elevated PAWP (≥ 15 mmHg) by receiver operating characteristic (ROC) analysis, overall and in the pre-specified subgroup with left atrial volume index (LAVi) < 48 mL/m². In patients undergoing sodium nitroprusside challenge, invasive and echocardiographic PAWP change (ΔPAWP) was analyzed and compared. Of 176 patients enrolled, 172 (mean age was 52.6 ± 12.1 years and 76.2% were males), had an interpretable PAWP and formed the analytic cohort; 77 (44.8%) had PAWP ≥ 15 mmHg. Correlation with invasive PAWP was ρ = 0.452 for Nagueh (n = 148) and ρ = 0.550 for ePAWP-E (n = 156, both p < 0.001), with AUC 0.759 (95% CI 0.677-0.833) and 0.798 (95% CI 0723-0.864). Both equations overestimated invasive PAWP (bias + 3.2 and + 2.6 mmHg) with wide limits of agreement (-13.3 to + 19.7 and - 11.6 to + 16.8 mmHg). In the LAVi < 48 mL/m² subgroup, agreement improved (ρ = 0.496 vs. 0.655; AUC 0.850 and 0.927) and the limits of agreement for ePAWP-E narrowed to - 8.3 to + 10.3 mmHg. During nitroprusside challenge, invasive ΔPAWP was 9.6 ± 7.6 mmHg whereas echocardiographic ΔePAWP was 2.4 ± 5.6 mmHg (Nagueh, n = 33) and 1.5 ± 6.0 mmHg (ePAWP-E, n = 34; both p < 0.001 vs. invasive), with weak Δ correlations (ρ = 0.414 and 0.389). In AdvHF, echocardiographic equations correlate only moderately with invasive PAWP and are not accurate enough for individual-level quantification. The LAVi- and E-based equation performs best and may be used to rule in or rule out elevated filling pressures at rest when the left atrium is not severely dilated. Neither equation tracks the acute PAWP changes induced by vasodilator challenge, so RHC remains indispensable whenever the clinical question is dynamic.

超声心动图估计晚期心力衰竭患者肺动脉楔压:与右心导管置入术的头对头比较。
已经提出了几个方程来无创地估计肺动脉楔压(PAWP),并已验证了对右心导管(RHC)的有效性。然而,它们在晚期心力衰竭(AdvHF)患者中的准确性仍不确定。我们评估了静息和血管扩张剂试验时超声心动图和有创PAWP测量的一致性。前瞻性纳入了24小时内连续接受AdvHF的经胸超声心动图(TTE)和RHC配对的患者。超声心动图PAWP计算采用Nagueh E/ E’方程、左房容积指数(LAVi)和Lindow报告的二尖瓣方程(ePAWP-E)。采用Spearman相关和Blant-Altman分析评估有创性PAWP的一致性,并通过受试者工作特征(ROC)分析,在总体和预先指定的左房容积指数(LAVi)亚组中区分PAWP升高(≥15mmhg)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书