Using a basic life support stress-test to assess the influence of ethanol-based hand rubs nitril gloves and of physically demanding clinical tasks on personal protective equipment fit (GLOVDIS-1) - a pilot Manikin study.

IF 1.1 Q3 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH
GMS Hygiene and Infection Control Pub Date : 2026-07-17 eCollection Date: 2026-01-01 DOI:10.3205/dgkh000666
Tobias P Taubner, Michael Bentele, Florian Salm, Dario Zocholl, Benjamin Taubner, Stefan Bushuven, Nico T Mutters
{"title":"Using a basic life support stress-test to assess the influence of ethanol-based hand rubs nitril gloves and of physically demanding clinical tasks on personal protective equipment fit (GLOVDIS-1) - a pilot Manikin study.","authors":"Tobias P Taubner, Michael Bentele, Florian Salm, Dario Zocholl, Benjamin Taubner, Stefan Bushuven, Nico T Mutters","doi":"10.3205/dgkh000666","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>Hand hygiene and personal protective equipment (PPE) are essential components for infection control. However, existing data are inconclusive regarding the impact of ethanol-based hand rubs on glove integrity, and evidence is limited on whether individual PPE components maintain adequate fit and usability during physically demanding clinical tasks. This pilot study aimed to evaluate the feasibility of a simulation-based protocol, designed to investigate hygiene- and PPE-related benefits and limitations under realistic emergency conditions.</p><p><strong>Methods: </strong>In a prospective observational study, 60 health care workers (HCW) pairwise performed two cycles of cardiopulmonary resuscitation (CPR) according to Basic Life Support standards while wearing full personal protective equipment. Participants were double-gloved; outer gloves were disinfected with an ethanol-based hand rub (EBHR), while the inner gloves remained native. Glove integrity was assessed according to DIN EN 455-1, and subjective PPE fit was rated before and after CPR. Feasibility, glove leakage, and changes in PPE fit were analyzed descriptively and exploratorily.</p><p><strong>Results: </strong>The study protocol proved feasible, with no dropouts and successful integrity testing of 478 out of 480 gloves. Glove leakage occurred in 3.8% of gloves, with no significant difference between disinfected and native gloves. Subjective PPE fit remained unchanged for gloves, respirators, and eye protective devices, whereas gown fit deteriorated significantly after CPR.</p><p><strong>Conclusion: </strong>This pilot study demonstrates the feasibility of a standardized simulation-based Basic Life Support stress test to investigate the influence of glove disinfection with two different EBHRs on PPE performance under simulated emergency conditions. Ethanol-based glove disinfection did not increase glove leakage, whereas gown fit deteriorated during CPR. Larger, adequately powered studies may base on these results to further evaluate PPE performance and inform evidence-based infection prevention strategies in emergency care.</p>","PeriodicalId":12738,"journal":{"name":"GMS Hygiene and Infection Control","volume":"21 ","pages":"Doc57"},"PeriodicalIF":1.1000,"publicationDate":"2026-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13585032/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"GMS Hygiene and Infection Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3205/dgkh000666","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: Hand hygiene and personal protective equipment (PPE) are essential components for infection control. However, existing data are inconclusive regarding the impact of ethanol-based hand rubs on glove integrity, and evidence is limited on whether individual PPE components maintain adequate fit and usability during physically demanding clinical tasks. This pilot study aimed to evaluate the feasibility of a simulation-based protocol, designed to investigate hygiene- and PPE-related benefits and limitations under realistic emergency conditions.

Methods: In a prospective observational study, 60 health care workers (HCW) pairwise performed two cycles of cardiopulmonary resuscitation (CPR) according to Basic Life Support standards while wearing full personal protective equipment. Participants were double-gloved; outer gloves were disinfected with an ethanol-based hand rub (EBHR), while the inner gloves remained native. Glove integrity was assessed according to DIN EN 455-1, and subjective PPE fit was rated before and after CPR. Feasibility, glove leakage, and changes in PPE fit were analyzed descriptively and exploratorily.

Results: The study protocol proved feasible, with no dropouts and successful integrity testing of 478 out of 480 gloves. Glove leakage occurred in 3.8% of gloves, with no significant difference between disinfected and native gloves. Subjective PPE fit remained unchanged for gloves, respirators, and eye protective devices, whereas gown fit deteriorated significantly after CPR.

Conclusion: This pilot study demonstrates the feasibility of a standardized simulation-based Basic Life Support stress test to investigate the influence of glove disinfection with two different EBHRs on PPE performance under simulated emergency conditions. Ethanol-based glove disinfection did not increase glove leakage, whereas gown fit deteriorated during CPR. Larger, adequately powered studies may base on these results to further evaluate PPE performance and inform evidence-based infection prevention strategies in emergency care.

使用基本生命支持压力测试来评估基于乙醇的手部摩擦、丁腈手套和体力要求高的临床任务对个人防护装备适配性的影响(GLOVDIS-1)——一项人体模型试验研究。
目的:手部卫生和个人防护装备(PPE)是感染控制的基本组成部分。然而,关于以乙醇为基础的手部摩擦对手套完整性的影响,现有数据尚无定论,关于个人防护用品组件在体力要求高的临床任务中是否保持适当的适用性和可用性的证据有限。这项试点研究旨在评估基于模拟的方案的可行性,该方案旨在调查现实紧急情况下卫生和ppe相关的益处和局限性。方法:在前瞻性观察研究中,60名医护人员在穿戴全套个人防护装备的情况下,按照基本生命支持标准成对实施了两个周期的心肺复苏(CPR)。参与者戴着双手套;外手套用乙醇基洗手液消毒,内手套保持原液消毒。根据DIN EN 455-1评估手套的完整性,并在心肺复苏术前后对主观PPE适合度进行评估。描述性和探索性地分析了可行性、手套泄漏和PPE合身的变化。结果:研究方案被证明是可行的,没有掉包,480只手套中有478只成功进行了完整性测试。手套渗漏率为3.8%,消毒手套与普通手套无显著差异。手套、呼吸器和护目镜的主观PPE合身度保持不变,而心肺复苏术后长袍的合身度明显恶化。结论:本试点研究验证了基于标准化模拟的基本生命支持压力测试的可行性,以研究在模拟紧急情况下,用两种不同的EBHRs消毒手套对PPE性能的影响。以乙醇为基础的手套消毒不会增加手套泄漏,而在心肺复苏术期间,工作服的合身性恶化。规模更大、动力更充分的研究可以基于这些结果进一步评估个人防护装备的表现,并为急诊护理中的循证感染预防策略提供信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
GMS Hygiene and Infection Control
GMS Hygiene and Infection Control PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-
自引率
0.00%
发文量
12
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书