Accuracy of CT-derived interarterial and intramural anomalous coronary arteries anatomy compared with 3D-reconstructed IVUS in-vivo reference.

IF 1.5
Anselm W Stark, Ali Mokhtari, Ryota Kakizaki, Marius R Bigler, Marc Ilic, Afreed Ashraf, Kiril Stoyanov, Christoph Ryffel, Lorenz Räber, Isaac Shiri, Christoph Gräni
{"title":"Accuracy of CT-derived interarterial and intramural anomalous coronary arteries anatomy compared with 3D-reconstructed IVUS in-vivo reference.","authors":"Anselm W Stark, Ali Mokhtari, Ryota Kakizaki, Marius R Bigler, Marc Ilic, Afreed Ashraf, Kiril Stoyanov, Christoph Ryffel, Lorenz Räber, Isaac Shiri, Christoph Gräni","doi":"10.1007/s10554-026-03820-8","DOIUrl":null,"url":null,"abstract":"<p><p>In anomalous aortic origin of a coronary artery (AAOCA), coronary CT angiography (CCTA) is the primary tool for anatomical assessment. However, CCTA measurements lack validation against a high-resolution in-vivo standard. To assess CCTA reliability for lumen dimensions and intramural length (IML) in AAOCA, and to validate these against a three-dimensionally reconstructed intravascular ultrasound (3D-IVUS) reference using three additional IML methodologies. A total of 60 AAOCA patients with an interarterial/intramural course underwent both CCTA and IVUS. A 3D-IVUS was constructed and its geometric reproducibility assessed. CCTA reliability and agreement with 3D-IVUS were evaluated for ostial dimensions, position-dependent minimal lumen area (MLA), and IML, measured by interluminal space thickness (ILS), elliptic ratio, and pericoronary fat sign. 3D-IVUS reference standard showed excellent geometric reproducibility (median point-wise distance 0.19 mm, 95%CI 0.07-0.43 mm) and good-to-excellent intrareader reliability (ICC 0.72-0.96). CCTA intra- and inter-reader reliability was moderate-to-excellent for ostial parameters and ILS-derived IML (ICC 0.69-0.92) and poor-to-good for MLA (ICC 0.28-0.87). Against 3D-IVUS, CCTA ostial area demonstrated moderate correlation (r = 0.73, p < 0.001) with minimal bias, and ILS-derived IML showed moderate agreement (r = 0.59; bias + 0.23 mm), while the fat sign substantially overestimated length (+ 7.88 mm). Using 3D-IVUS as an in-vivo reference standard for the precise assessment of coronary anatomy in AAOCA, CCTA provided reproducible ostial measurements, and the ILS-based method showed the best performance among the evaluated CCTA approaches for estimating intramural length. However, wide limits of agreement preclude precise individual sizing, and position-dependent MLA measurements remain unreliable.</p>","PeriodicalId":94227,"journal":{"name":"The international journal of cardiovascular imaging","volume":" ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2026-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The international journal of cardiovascular imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10554-026-03820-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In anomalous aortic origin of a coronary artery (AAOCA), coronary CT angiography (CCTA) is the primary tool for anatomical assessment. However, CCTA measurements lack validation against a high-resolution in-vivo standard. To assess CCTA reliability for lumen dimensions and intramural length (IML) in AAOCA, and to validate these against a three-dimensionally reconstructed intravascular ultrasound (3D-IVUS) reference using three additional IML methodologies. A total of 60 AAOCA patients with an interarterial/intramural course underwent both CCTA and IVUS. A 3D-IVUS was constructed and its geometric reproducibility assessed. CCTA reliability and agreement with 3D-IVUS were evaluated for ostial dimensions, position-dependent minimal lumen area (MLA), and IML, measured by interluminal space thickness (ILS), elliptic ratio, and pericoronary fat sign. 3D-IVUS reference standard showed excellent geometric reproducibility (median point-wise distance 0.19 mm, 95%CI 0.07-0.43 mm) and good-to-excellent intrareader reliability (ICC 0.72-0.96). CCTA intra- and inter-reader reliability was moderate-to-excellent for ostial parameters and ILS-derived IML (ICC 0.69-0.92) and poor-to-good for MLA (ICC 0.28-0.87). Against 3D-IVUS, CCTA ostial area demonstrated moderate correlation (r = 0.73, p < 0.001) with minimal bias, and ILS-derived IML showed moderate agreement (r = 0.59; bias + 0.23 mm), while the fat sign substantially overestimated length (+ 7.88 mm). Using 3D-IVUS as an in-vivo reference standard for the precise assessment of coronary anatomy in AAOCA, CCTA provided reproducible ostial measurements, and the ILS-based method showed the best performance among the evaluated CCTA approaches for estimating intramural length. However, wide limits of agreement preclude precise individual sizing, and position-dependent MLA measurements remain unreliable.

ct衍生的动脉间和壁内异常冠状动脉解剖与3d重建IVUS体内参考的准确性比较。
在冠状动脉异常起源(AAOCA)中,冠状动脉CT血管造影(CCTA)是解剖评估的主要工具。然而,CCTA测量缺乏针对高分辨率体内标准的验证。评估CCTA对AAOCA的管腔尺寸和壁内长度(IML)的可靠性,并使用另外三种IML方法对三维重建血管内超声(3D-IVUS)参考进行验证。共有60例AAOCA动脉间/壁内病程患者同时接受了CCTA和IVUS。构建3D-IVUS并评估其几何再现性。评估CCTA的可靠性和与3D-IVUS的一致性,包括开口尺寸、位置相关的最小管腔面积(MLA)和IML,通过腔间空间厚度(ILS)、椭圆比和冠状动脉周围脂肪征象测量。3D-IVUS标准品具有良好的几何再现性(中位点距0.19 mm, 95%CI 0.07-0.43 mm)和良好至优异的阅读器内信度(ICC 0.72-0.96)。CCTA读卡器内和读卡器间的信度对于口参数和il衍生的IML (ICC 0.69-0.92)为中等至优秀,对于MLA (ICC 0.28-0.87)为差至良好。与3D-IVUS相比,CCTA口腔面积显示中度相关性(r = 0.73, p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书