{"title":"Design and Validation of a High-Power Radiation-Hardened DC/DC Converter Based on Bidirectional Magnetic Isolation","authors":"Xiaojin Lu;Gang Dong;Qifeng He;Ziyu Zhou;Xinfang Liao","doi":"10.1109/TNS.2026.3723944","DOIUrl":null,"url":null,"abstract":"This article proposes a bidirectional magnetically isolated feedback technique for isolated regulation. By using an isolation transformer to transfer feedback/control information bidirectionally via magnetic coupling, it enables a fully isolated closed-loop regulation and, at the mechanism level, avoids regulation drift and failure risks caused by optocoupler current transfer ratio (CTR) degradation under ionizing radiation. Based on this technique, a 150-W isolated DC/DC converter is designed and implemented for cost-sensitive low-Earth-orbit (LEO) platforms. The converter adopts thick-film hybrid integrated circuit (HIC) technology and a single-ended forward power stage, with the magnetic feedback link driven by radiation-tolerant analog components. The prototype delivers a regulated 28-V output over a 16–50 V input range, achieves a power density of 100 W/in<sup>3</sup> in a <inline-formula> <tex-math>$63.5\\times 38.3\\times 10.16$ </tex-math></inline-formula> mm<sup>3</sup> hermetic package, and maintains <inline-formula> <tex-math>$\\ge 85$ </tex-math></inline-formula>% full-load efficiency at room temperature. To validate the reliability of this technical route, single-event effect (SEE) and total ionizing dose (TID) tests were conducted: the initial SEE campaign at the Heavy Ion Research Facility in Lanzhou (HIRFL) identified single-event-induced overstress risks in the auxiliary supply and secondary feedback circuitry, and targeted hardening measures were implemented accordingly; after hardening, no catastrophic failures were observed. TID testing up to 100 krad(Si) shows strong dose-rate dependence, with more pronounced degradation at 0.01 rad(Si)/s, consistent with enhanced low-dose-rate sensitivity (ELDRS).","PeriodicalId":13406,"journal":{"name":"IEEE Transactions on Nuclear Science","volume":"73 9","pages":"3618-3628"},"PeriodicalIF":2.4000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Nuclear Science","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11693996/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
This article proposes a bidirectional magnetically isolated feedback technique for isolated regulation. By using an isolation transformer to transfer feedback/control information bidirectionally via magnetic coupling, it enables a fully isolated closed-loop regulation and, at the mechanism level, avoids regulation drift and failure risks caused by optocoupler current transfer ratio (CTR) degradation under ionizing radiation. Based on this technique, a 150-W isolated DC/DC converter is designed and implemented for cost-sensitive low-Earth-orbit (LEO) platforms. The converter adopts thick-film hybrid integrated circuit (HIC) technology and a single-ended forward power stage, with the magnetic feedback link driven by radiation-tolerant analog components. The prototype delivers a regulated 28-V output over a 16–50 V input range, achieves a power density of 100 W/in3 in a $63.5\times 38.3\times 10.16$ mm3 hermetic package, and maintains $\ge 85$ % full-load efficiency at room temperature. To validate the reliability of this technical route, single-event effect (SEE) and total ionizing dose (TID) tests were conducted: the initial SEE campaign at the Heavy Ion Research Facility in Lanzhou (HIRFL) identified single-event-induced overstress risks in the auxiliary supply and secondary feedback circuitry, and targeted hardening measures were implemented accordingly; after hardening, no catastrophic failures were observed. TID testing up to 100 krad(Si) shows strong dose-rate dependence, with more pronounced degradation at 0.01 rad(Si)/s, consistent with enhanced low-dose-rate sensitivity (ELDRS).
期刊介绍:
The IEEE Transactions on Nuclear Science is a publication of the IEEE Nuclear and Plasma Sciences Society. It is viewed as the primary source of technical information in many of the areas it covers. As judged by JCR impact factor, TNS consistently ranks in the top five journals in the category of Nuclear Science & Technology. It has one of the higher immediacy indices, indicating that the information it publishes is viewed as timely, and has a relatively long citation half-life, indicating that the published information also is viewed as valuable for a number of years.
The IEEE Transactions on Nuclear Science is published bimonthly. Its scope includes all aspects of the theory and application of nuclear science and engineering. It focuses on instrumentation for the detection and measurement of ionizing radiation; particle accelerators and their controls; nuclear medicine and its application; effects of radiation on materials, components, and systems; reactor instrumentation and controls; and measurement of radiation in space.