{"title":"[Comparative experimental evaluation of the efficacy and tissue trauma associated with puncture needles for percutaneous renal access].","authors":"S Gazimiev E, L Medvedev V, A Terman E","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Despite the high prevalence of obstructive uropathy in emergency urological practice, retrograde and antegrade drainage of the urinary tract remain the main surgical treatment methods. Percutaneous nephrostomy is a minimally invasive procedure; nevertheless, it is associated with a risk of intra- and postoperative complications. A key stage of this procedure is accurate and safe puncture of the renal collecting system, which largely determines the outcome of the intervention and the incidence of possible complications.</p><p><strong>Objective: </strong>To compare the characteristics and safety profile of the new domestically developed low-trauma MG-New puncture needle with puncture needles traditionally used in urological practice.</p><p><strong>Materials and methods: </strong>Surgical procedures were performed in two pigs. In the first series, percutaneous punctures of the renal collecting system were performed using the standard technique under ultrasound guidance with three types of needles: MG-New, Chiba, and a trocar needle (Coloplast A/S, Denmark). In the second series, punctures of the renal collecting system were performed under laparoscopic guidance through a trocar port to assess macroscopic post-puncture traumatic changes. The final stage consisted of bilateral nephrectomy followed by histological examination of the obtained tissue specimens.</p><p><strong>Results: </strong>The MG-New needle demonstrated greater efficacy and safety than the conventional needles. The extensive echogenic laser-marked surface improved visualization, while the distal-end design was associated with minimal tissue trauma and limited vascular injury. These findings support the potential advantages of the needle for percutaneous renal interventions.</p><p><strong>Conclusion: </strong>The MG-New needle provides significant advantages over conventionally used Chiba and trocar needles during percutaneous renal puncture.</p>","PeriodicalId":23546,"journal":{"name":"Urologiia","volume":" 4","pages":"5-15"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urologiia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Despite the high prevalence of obstructive uropathy in emergency urological practice, retrograde and antegrade drainage of the urinary tract remain the main surgical treatment methods. Percutaneous nephrostomy is a minimally invasive procedure; nevertheless, it is associated with a risk of intra- and postoperative complications. A key stage of this procedure is accurate and safe puncture of the renal collecting system, which largely determines the outcome of the intervention and the incidence of possible complications.

Objective: To compare the characteristics and safety profile of the new domestically developed low-trauma MG-New puncture needle with puncture needles traditionally used in urological practice.

Materials and methods: Surgical procedures were performed in two pigs. In the first series, percutaneous punctures of the renal collecting system were performed using the standard technique under ultrasound guidance with three types of needles: MG-New, Chiba, and a trocar needle (Coloplast A/S, Denmark). In the second series, punctures of the renal collecting system were performed under laparoscopic guidance through a trocar port to assess macroscopic post-puncture traumatic changes. The final stage consisted of bilateral nephrectomy followed by histological examination of the obtained tissue specimens.

Results: The MG-New needle demonstrated greater efficacy and safety than the conventional needles. The extensive echogenic laser-marked surface improved visualization, while the distal-end design was associated with minimal tissue trauma and limited vascular injury. These findings support the potential advantages of the needle for percutaneous renal interventions.

Conclusion: The MG-New needle provides significant advantages over conventionally used Chiba and trocar needles during percutaneous renal puncture.

[穿刺针经皮肾通路疗效及组织损伤的对比实验评价]。
导读:尽管梗阻性尿路病变在急诊泌尿外科的发病率很高,但逆行和顺行尿路引流仍然是主要的手术治疗方法。经皮肾造口术是一种微创手术;然而,它与手术内和术后并发症的风险相关。该手术的一个关键阶段是准确和安全的穿刺肾收集系统,这在很大程度上决定了干预的结果和可能的并发症的发生率。目的:比较国产低创伤MG-New穿刺针与泌尿外科传统穿刺针的特点和安全性。材料和方法:对2头猪进行了外科手术。在第一个系列中,采用超声引导下的标准技术,使用MG-New、Chiba和套管针(Coloplast a /S,丹麦)三种针进行肾收集系统的经皮穿刺。在第二个系列中,在腹腔镜引导下通过套管针口穿刺肾收集系统,以评估穿刺后的宏观创伤变化。最后阶段包括双侧肾切除术,然后对获得的组织标本进行组织学检查。结果:MG-New针比传统针具有更高的疗效和安全性。广泛的激光回波标记表面改善了可视化,而远端设计与最小的组织创伤和有限的血管损伤有关。这些发现支持针在经皮肾介入治疗中的潜在优势。结论:MG-New针在经皮肾穿刺中较传统千叶针和套管针有明显优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Urologiia
Urologiia Medicine-Medicine (all)
CiteScore
0.80
自引率
0.00%
发文量
160
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书