{"title":"[Comparative experimental evaluation of the efficacy and tissue trauma associated with puncture needles for percutaneous renal access].","authors":"S Gazimiev E, L Medvedev V, A Terman E","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Despite the high prevalence of obstructive uropathy in emergency urological practice, retrograde and antegrade drainage of the urinary tract remain the main surgical treatment methods. Percutaneous nephrostomy is a minimally invasive procedure; nevertheless, it is associated with a risk of intra- and postoperative complications. A key stage of this procedure is accurate and safe puncture of the renal collecting system, which largely determines the outcome of the intervention and the incidence of possible complications.</p><p><strong>Objective: </strong>To compare the characteristics and safety profile of the new domestically developed low-trauma MG-New puncture needle with puncture needles traditionally used in urological practice.</p><p><strong>Materials and methods: </strong>Surgical procedures were performed in two pigs. In the first series, percutaneous punctures of the renal collecting system were performed using the standard technique under ultrasound guidance with three types of needles: MG-New, Chiba, and a trocar needle (Coloplast A/S, Denmark). In the second series, punctures of the renal collecting system were performed under laparoscopic guidance through a trocar port to assess macroscopic post-puncture traumatic changes. The final stage consisted of bilateral nephrectomy followed by histological examination of the obtained tissue specimens.</p><p><strong>Results: </strong>The MG-New needle demonstrated greater efficacy and safety than the conventional needles. The extensive echogenic laser-marked surface improved visualization, while the distal-end design was associated with minimal tissue trauma and limited vascular injury. These findings support the potential advantages of the needle for percutaneous renal interventions.</p><p><strong>Conclusion: </strong>The MG-New needle provides significant advantages over conventionally used Chiba and trocar needles during percutaneous renal puncture.</p>","PeriodicalId":23546,"journal":{"name":"Urologiia","volume":" 4","pages":"5-15"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urologiia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Despite the high prevalence of obstructive uropathy in emergency urological practice, retrograde and antegrade drainage of the urinary tract remain the main surgical treatment methods. Percutaneous nephrostomy is a minimally invasive procedure; nevertheless, it is associated with a risk of intra- and postoperative complications. A key stage of this procedure is accurate and safe puncture of the renal collecting system, which largely determines the outcome of the intervention and the incidence of possible complications.
Objective: To compare the characteristics and safety profile of the new domestically developed low-trauma MG-New puncture needle with puncture needles traditionally used in urological practice.
Materials and methods: Surgical procedures were performed in two pigs. In the first series, percutaneous punctures of the renal collecting system were performed using the standard technique under ultrasound guidance with three types of needles: MG-New, Chiba, and a trocar needle (Coloplast A/S, Denmark). In the second series, punctures of the renal collecting system were performed under laparoscopic guidance through a trocar port to assess macroscopic post-puncture traumatic changes. The final stage consisted of bilateral nephrectomy followed by histological examination of the obtained tissue specimens.
Results: The MG-New needle demonstrated greater efficacy and safety than the conventional needles. The extensive echogenic laser-marked surface improved visualization, while the distal-end design was associated with minimal tissue trauma and limited vascular injury. These findings support the potential advantages of the needle for percutaneous renal interventions.
Conclusion: The MG-New needle provides significant advantages over conventionally used Chiba and trocar needles during percutaneous renal puncture.
导读:尽管梗阻性尿路病变在急诊泌尿外科的发病率很高,但逆行和顺行尿路引流仍然是主要的手术治疗方法。经皮肾造口术是一种微创手术;然而,它与手术内和术后并发症的风险相关。该手术的一个关键阶段是准确和安全的穿刺肾收集系统,这在很大程度上决定了干预的结果和可能的并发症的发生率。目的:比较国产低创伤MG-New穿刺针与泌尿外科传统穿刺针的特点和安全性。材料和方法:对2头猪进行了外科手术。在第一个系列中,采用超声引导下的标准技术,使用MG-New、Chiba和套管针(Coloplast a /S,丹麦)三种针进行肾收集系统的经皮穿刺。在第二个系列中,在腹腔镜引导下通过套管针口穿刺肾收集系统,以评估穿刺后的宏观创伤变化。最后阶段包括双侧肾切除术,然后对获得的组织标本进行组织学检查。结果:MG-New针比传统针具有更高的疗效和安全性。广泛的激光回波标记表面改善了可视化,而远端设计与最小的组织创伤和有限的血管损伤有关。这些发现支持针在经皮肾介入治疗中的潜在优势。结论:MG-New针在经皮肾穿刺中较传统千叶针和套管针有明显优势。