Electrochemical cardiac troponin I immunosensor platform integrated with electrochemically deposited Au nanoparticles decorated PtNi bimetallic sponge-like structures.

IF 4.9 2区 化学 Q1 BIOCHEMISTRY & MOLECULAR BIOLOGY
Mustafa Ali Güngör, Merve Yıldırım, Filiz Kuralay
{"title":"Electrochemical cardiac troponin I immunosensor platform integrated with electrochemically deposited Au nanoparticles decorated PtNi bimetallic sponge-like structures.","authors":"Mustafa Ali Güngör, Merve Yıldırım, Filiz Kuralay","doi":"10.1016/j.bioelechem.2026.109443","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, a novel, reproducible, and stable electrochemical detection platform was developed for the detection of cardiac troponin I (cTnI), one of the most common biomarkers of cardiovascular diseases. The immunosensing platform consisted of antibody functionalized electrochemically gold (Au) deposited sponge-like platinum‑nickel (PtNi)-based nanoparticles modified screen-printed carbon electrodes (SPCEs). A sponge-like surface yielded a high surface area that enabled effective Au deposition and enhanced electrochemical properties through a synergistic effect. Electrochemically deposited Au onto this surface not only improved electrochemical characteristics but also created an environment in which the antibody could settle effectively. The final version of the electrode demonstrated high sensitivity. The sensor (anti-cTnI/Au@Pt-Ni/SPCE) performance was achieved in the linear working range of 0.01 pg/mL-100 ng/mL with a low limit of detection (LOD) value of 8.09 fg/mL using EIS technique. The selectivity studies showed that the proposed electrode had successful results in the presence of important interfering species. Good recovery was obtained in diluted serum samples ranging between 97.3 and 103.6%. Amperometric detection strategy was also evaluated with the metal-based nanoparticles modified electrode, and a low LOD value of 3.93 fg/mL was obtained. The modified electrode was successfully characterized using microscopic, spectroscopic, contact angle, and electrochemical techniques.</p>","PeriodicalId":252,"journal":{"name":"Bioelectrochemistry","volume":" ","pages":"109443"},"PeriodicalIF":4.9000,"publicationDate":"2026-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioelectrochemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.bioelechem.2026.109443","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, a novel, reproducible, and stable electrochemical detection platform was developed for the detection of cardiac troponin I (cTnI), one of the most common biomarkers of cardiovascular diseases. The immunosensing platform consisted of antibody functionalized electrochemically gold (Au) deposited sponge-like platinum‑nickel (PtNi)-based nanoparticles modified screen-printed carbon electrodes (SPCEs). A sponge-like surface yielded a high surface area that enabled effective Au deposition and enhanced electrochemical properties through a synergistic effect. Electrochemically deposited Au onto this surface not only improved electrochemical characteristics but also created an environment in which the antibody could settle effectively. The final version of the electrode demonstrated high sensitivity. The sensor (anti-cTnI/Au@Pt-Ni/SPCE) performance was achieved in the linear working range of 0.01 pg/mL-100 ng/mL with a low limit of detection (LOD) value of 8.09 fg/mL using EIS technique. The selectivity studies showed that the proposed electrode had successful results in the presence of important interfering species. Good recovery was obtained in diluted serum samples ranging between 97.3 and 103.6%. Amperometric detection strategy was also evaluated with the metal-based nanoparticles modified electrode, and a low LOD value of 3.93 fg/mL was obtained. The modified electrode was successfully characterized using microscopic, spectroscopic, contact angle, and electrochemical techniques.

电化学沉积金纳米粒子修饰PtNi双金属海绵状结构的电化学心脏肌钙蛋白I免疫传感器平台。
在这项研究中,开发了一种新的、可重复的、稳定的电化学检测平台,用于检测心脏肌钙蛋白I (cTnI),这是心血管疾病最常见的生物标志物之一。该免疫传感平台由抗体功能化的电化学金(Au)沉积海绵状铂镍(PtNi)基纳米颗粒修饰的丝网印刷碳电极(spce)组成。海绵状表面产生了高表面积,可以有效沉积金,并通过协同效应增强电化学性能。电化学镀金不仅改善了表面的电化学特性,而且为抗体的有效沉降创造了良好的环境。最终版本的电极显示出高灵敏度。该传感器(anti-cTnI/Au@Pt-Ni/SPCE)在0.01 pg/mL ~ 100 ng/mL的线性工作范围内性能良好,EIS技术的低检出限为8.09 fg/mL。选择性研究表明,该电极在存在重要干扰物质的情况下取得了成功的结果。在稀释后的血清样品中,回收率在97.3 ~ 103.6%之间。对金属基纳米粒子修饰电极的安培检测策略进行了评价,获得了低LOD值3.93 fg/mL。利用显微、光谱、接触角和电化学技术成功地对修饰电极进行了表征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Bioelectrochemistry
Bioelectrochemistry 生物-电化学
CiteScore
9.10
自引率
6.00%
发文量
238
审稿时长
38 days
期刊介绍: An International Journal Devoted to Electrochemical Aspects of Biology and Biological Aspects of Electrochemistry Bioelectrochemistry is an international journal devoted to electrochemical principles in biology and biological aspects of electrochemistry. It publishes experimental and theoretical papers dealing with the electrochemical aspects of: • Electrified interfaces (electric double layers, adsorption, electron transfer, protein electrochemistry, basic principles of biosensors, biosensor interfaces and bio-nanosensor design and construction. • Electric and magnetic field effects (field-dependent processes, field interactions with molecules, intramolecular field effects, sensory systems for electric and magnetic fields, molecular and cellular mechanisms) • Bioenergetics and signal transduction (energy conversion, photosynthetic and visual membranes) • Biomembranes and model membranes (thermodynamics and mechanics, membrane transport, electroporation, fusion and insertion) • Electrochemical applications in medicine and biotechnology (drug delivery and gene transfer to cells and tissues, iontophoresis, skin electroporation, injury and repair). • Organization and use of arrays in-vitro and in-vivo, including as part of feedback control. • Electrochemical interrogation of biofilms as generated by microorganisms and tissue reaction associated with medical implants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书