Effects of Spatial Ambient Illumination on Pupil Diameter and Visual Acuity.

IF 2.4
Pham Hong Duong, Pham Hoang Minh, Nguyen Tri Duc, Nguyen Van Quan, Hoang Thu Thuy, Tran Minh Anh, Duong Thi Giang
{"title":"Effects of Spatial Ambient Illumination on Pupil Diameter and Visual Acuity.","authors":"Pham Hong Duong, Pham Hoang Minh, Nguyen Tri Duc, Nguyen Van Quan, Hoang Thu Thuy, Tran Minh Anh, Duong Thi Giang","doi":"10.1007/s44402-026-00187-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Although chart luminance is carefully standardised in visual acuity (VA) testing, the luminance and spatial distribution of the surrounding illumination are less clearly defined. This study investigated how central luminance, peripheral field illumination and ambient room illumination influence pupil diameter and VA during small-field visual tasks.</p><p><strong>Methods: </strong>A programmable light-emitting diode (LED) illumination system was developed to manipulate central chart luminance, peripheral field illumination and ambient room illumination surrounding a central Early Treatment of Diabetic Retinopathy Study (ETDRS) chart independently. VA and pupil diameter were measured in 201 participants under multiple lighting conditions. Relationships among illumination parameters, pupil diameter and VA were evaluated using paired comparisons and regression analysis.</p><p><strong>Results: </strong>Increasing central luminance from 20 to 640 cd/m² reduced mean pupil diameter from 5.93 to 3.61 mm and improved VA from 0.02 to -0.13 logMAR. At constant central luminance (160 cd/m²), increasing peripheral field extent and ambient illumination produced additional pupil constriction and modest improvements in VA. Changes in pupil diameter were significantly associated with changes in VA (r = 0.67, p < 0.001).</p><p><strong>Conclusion: </strong>The spatial distribution of illumination significantly influences pupil diameter and VA, even when central chart luminance remains unchanged. Both peripheral field illumination and ambient room lighting were associated with pupil constriction and modest improvements in VA. These findings highlight the importance of spatial illumination in visual performance and suggest that ambient lighting conditions should be considered in visual acuity assessment and visual environment design.</p>","PeriodicalId":520731,"journal":{"name":"Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s44402-026-00187-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Although chart luminance is carefully standardised in visual acuity (VA) testing, the luminance and spatial distribution of the surrounding illumination are less clearly defined. This study investigated how central luminance, peripheral field illumination and ambient room illumination influence pupil diameter and VA during small-field visual tasks.

Methods: A programmable light-emitting diode (LED) illumination system was developed to manipulate central chart luminance, peripheral field illumination and ambient room illumination surrounding a central Early Treatment of Diabetic Retinopathy Study (ETDRS) chart independently. VA and pupil diameter were measured in 201 participants under multiple lighting conditions. Relationships among illumination parameters, pupil diameter and VA were evaluated using paired comparisons and regression analysis.

Results: Increasing central luminance from 20 to 640 cd/m² reduced mean pupil diameter from 5.93 to 3.61 mm and improved VA from 0.02 to -0.13 logMAR. At constant central luminance (160 cd/m²), increasing peripheral field extent and ambient illumination produced additional pupil constriction and modest improvements in VA. Changes in pupil diameter were significantly associated with changes in VA (r = 0.67, p < 0.001).

Conclusion: The spatial distribution of illumination significantly influences pupil diameter and VA, even when central chart luminance remains unchanged. Both peripheral field illumination and ambient room lighting were associated with pupil constriction and modest improvements in VA. These findings highlight the importance of spatial illumination in visual performance and suggest that ambient lighting conditions should be considered in visual acuity assessment and visual environment design.

空间环境光照对瞳孔直径和视敏度的影响。
目的:虽然视力表亮度在视敏度(VA)测试中被仔细标准化,但周围照明的亮度和空间分布却不太清楚。本研究考察了小视场视觉任务中中心亮度、外围视场照明和环境室内照明对瞳孔直径和视差的影响。方法:采用可编程发光二极管(LED)照明系统,独立控制糖尿病视网膜病变早期治疗研究(ETDRS)中心图表周围的中央图表亮度、外围场照明和环境室内照明。研究人员测量了201名参与者在多种光照条件下的视差和瞳孔直径。采用配对比较和回归分析评价光照参数、瞳孔直径和视差之间的关系。结果:中心亮度从20增加到640 cd/m²,平均瞳孔直径从5.93降低到3.61 mm, VA从0.02提高到-0.13 logMAR。在中心亮度不变(160 cd/m²)的情况下,增加外围视场范围和环境照度会使瞳孔进一步收缩,并适度改善视差。瞳孔直径的变化与视差的变化显著相关(r = 0.67, p)。结论:即使在中心亮度不变的情况下,照度的空间分布也会显著影响瞳孔直径和视差。周边视场照明和室内环境照明均与瞳孔收缩有关,并可适度改善视功能。这些研究结果强调了空间照明对视觉表现的重要性,并建议在视力评估和视觉环境设计中应考虑环境照明条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书