Hospital-Based Reference Values for Hertel Exophthalmometry in Nepal.

Clinical ophthalmology (Auckland, N.Z.) Pub Date : 2026-09-08 eCollection Date: 2026-01-01 DOI:10.2147/OPTH.S633842
Anup Subedi, Roshni Malla, Mario Cantó-Cerdán, Santosh Chhetri, Samriddhi Lamsal, Ravin Kumar Mishra, Umesh Belbase
{"title":"Hospital-Based Reference Values for Hertel Exophthalmometry in Nepal.","authors":"Anup Subedi, Roshni Malla, Mario Cantó-Cerdán, Santosh Chhetri, Samriddhi Lamsal, Ravin Kumar Mishra, Umesh Belbase","doi":"10.2147/OPTH.S633842","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Population-specific reference values for Hertel exophthalmometry are limited in South Asian populations, including Nepal. This limits clinical interpretation of ocular protrusion in routine practice. This study aimed to establish hospital-based reference values for exophthalmometry, evaluate intra-session measurement repeatability, and examine demographic and anthropometric associations.</p><p><strong>Methods: </strong>Participants aged 6-85 years attending the outpatient department were enrolled using systematic sampling, with every fifth eligible attendee selected. Because recruitment was conducted within a tertiary eye hospital rather than through population-based sampling, the study was designed to provide hospital-based reference data rather than nationally representative estimates. Hertel exophthalmometry was performed by a single examiner with three repeated measurements per eye. Intra-session repeatability was assessed using intraclass correlation coefficient (ICC) and coefficient of variation. Group comparisons were performed using non-parametric tests, and multivariable linear regression identified independent correlates of right eye exophthalmometry value (EV).</p><p><strong>Results: </strong>This study provides the first hospital-based reference data for exophthalmometry in a Nepali clinical population with excellent intra-session repeatability. Provisional upper reference limits are 17.42 mm (95<sup>th</sup> percentile) and 18.31 mm (mean plus 2SD). Inter-eye difference (IED) values exceeding 1.50 mm were uncommon in this sample (one participant, 0.2%). These findings are descriptive only; diagnostic thresholds for clinically significant asymmetry cannot be established from this study and require population-based investigations. Hertel base value (BV), age, ethnolinguistic ancestry, and geographical region were the independent associated with EV.</p><p><strong>Conclusion: </strong>This study provides hospital-based reference values for Hertel exophthalmometry in a Nepali population. Mean EV was approximately 13.5 mm, with a 95<sup>th</sup> percentile upper limit of 17.42 mm. Measurement repeatability was excellent. EV was independently associated with age, Hertel base value, and demographic grouping variables, although clinical interpretation should consider the methodological limitations of hospital-based sampling. These findings may assist clinicians in interpreting exophthalmometry in Nepal; however, population-based studies are needed to establish definitive normative ranges.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":"20 ","pages":"633842"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13570630/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S633842","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Population-specific reference values for Hertel exophthalmometry are limited in South Asian populations, including Nepal. This limits clinical interpretation of ocular protrusion in routine practice. This study aimed to establish hospital-based reference values for exophthalmometry, evaluate intra-session measurement repeatability, and examine demographic and anthropometric associations.

Methods: Participants aged 6-85 years attending the outpatient department were enrolled using systematic sampling, with every fifth eligible attendee selected. Because recruitment was conducted within a tertiary eye hospital rather than through population-based sampling, the study was designed to provide hospital-based reference data rather than nationally representative estimates. Hertel exophthalmometry was performed by a single examiner with three repeated measurements per eye. Intra-session repeatability was assessed using intraclass correlation coefficient (ICC) and coefficient of variation. Group comparisons were performed using non-parametric tests, and multivariable linear regression identified independent correlates of right eye exophthalmometry value (EV).

Results: This study provides the first hospital-based reference data for exophthalmometry in a Nepali clinical population with excellent intra-session repeatability. Provisional upper reference limits are 17.42 mm (95th percentile) and 18.31 mm (mean plus 2SD). Inter-eye difference (IED) values exceeding 1.50 mm were uncommon in this sample (one participant, 0.2%). These findings are descriptive only; diagnostic thresholds for clinically significant asymmetry cannot be established from this study and require population-based investigations. Hertel base value (BV), age, ethnolinguistic ancestry, and geographical region were the independent associated with EV.

Conclusion: This study provides hospital-based reference values for Hertel exophthalmometry in a Nepali population. Mean EV was approximately 13.5 mm, with a 95th percentile upper limit of 17.42 mm. Measurement repeatability was excellent. EV was independently associated with age, Hertel base value, and demographic grouping variables, although clinical interpretation should consider the methodological limitations of hospital-based sampling. These findings may assist clinicians in interpreting exophthalmometry in Nepal; however, population-based studies are needed to establish definitive normative ranges.

尼泊尔医院赫特尔眼验光的参考值
背景:在包括尼泊尔在内的南亚人群中,Hertel验光的特定参考值是有限的。这限制了临床对眼前突的解释。本研究旨在建立以医院为基础的刺眼测量参考值,评估术中测量的可重复性,并检查人口统计学和人体测量学的关联。方法:采用系统抽样的方法,选取年龄6 ~ 85岁的门诊患者,每5人中有1人入选。由于招募是在一家三级眼科医院进行的,而不是通过基于人群的抽样,因此该研究旨在提供基于医院的参考数据,而不是具有全国代表性的估计数据。赫特尔刺眼测量由一名检查者进行,每只眼睛进行三次重复测量。使用组内相关系数(ICC)和变异系数评估组内重复性。采用非参数检验进行组间比较,并采用多变量线性回归确定右眼外眼测量值(EV)的独立相关因素。结果:本研究为尼泊尔临床人群提供了第一个以医院为基础的刺眼测量参考数据,具有良好的会话内可重复性。临时参考上限为17.42 mm(第95百分位)和18.31 mm(平均值加2SD)。眼间差(IED)值超过1.50 mm在该样本中并不常见(1名参与者,0.2%)。这些发现只是描述性的;临床显著不对称的诊断阈值不能从本研究中确定,需要基于人群的调查。Hertel base value (BV)、年龄、民族语言血统、地理区域与EV独立相关。结论:本研究为尼泊尔人群的Hertel刺眼验光提供了基于医院的参考价值。平均EV约为13.5 mm,第95百分位上限为17.42 mm。测量重复性好。尽管临床解释应考虑基于医院抽样的方法学局限性,但EV与年龄、Hertel基础值和人口统计学分组变量独立相关。这些发现可能有助于临床医生解释在尼泊尔的刺眼;然而,需要基于人群的研究来确定明确的标准范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书