Keru Pu, Tengxiang Li, Shengnan Xu, Xue Sha, Qingtao Qiu, Jinming Yu, Yong Yin, Jie Liu
{"title":"C-X-C Motif Chemokine Receptor 4 (CXCR4)-Targeted Biologically Guided Proton Spatially Fractionated Radiotherapy for Bulky Limited-Stage Small Cell Lung Cancer.","authors":"Keru Pu, Tengxiang Li, Shengnan Xu, Xue Sha, Qingtao Qiu, Jinming Yu, Yong Yin, Jie Liu","doi":"10.1002/pro6.70095","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>To evaluate the feasibility and dosimetric safety of integrating C-X-C motif chemokine receptor 4 (CXCR4)-targeted tracer <sup>1</sup> <sup>8</sup>F-AlF-NOTA-QHY-04 positron emission tomography imaging with biologically guided proton spatially fractionated radiotherapy (BG-pSFRT) for bulky limited-stage small cell lung cancer.</p><p><strong>Materials and methods: </strong>Among 30 patients with bulky limited-stage small-cell lung cancer, a threshold range of 35%-40% of the maximum standard uptake value (SUV<sub>max</sub>) showed optimal spatial correspondence with the computed tomography-based gross tumor volume (GTV). The median SUV<sub>max</sub> was 6.96, and the Dice similarity coefficient ranged from 0.707 to 0.723. CXCR4-avid sub-volumes within GTV were characterized against the sub-targets of stereotactic body radiotherapy based partial tumor irradiation targeting hypoxic segments (SBRT-PATHY) and stereotactic centralized ablative radiation therapy (SCART). Dosimetric comparisons were performed between the BG-pSFRT and SCART plans (15-24 Gy per fraction in three fractions).</p><p><strong>Results: </strong>CXCR4-defined sub-volumes with low thresholds in BG-pSFRT demonstrated spatial concordance with putative hypoxic sub-volumes in SBRT-PATHY, whereas higher SUV<sub>max</sub> thresholds yielded multifocal distributions that exhibited spatial discordance relative to SCART, and these multifocal imaging-defined sub-volumes were targeted in BG-pSFRT for dose escalation. Compared to proton SCART, BG-pSFRT achieved greater high-dose (V<sub>80%</sub>), GTV coverage but slightly lower sub-volume conformity (89.04% vs. 95.55%; <i>P</i> < 0.001), and higher V<sub>5Gy</sub> and dose per fraction (<i>P</i> < 0.001). All organ-at-risk doses met the standard 3-fraction SBRT constraints.</p><p><strong>Conclusions: </strong>CXCR4-targeted BG-pSFRT may be a dosimetrically feasible strategy for bulky limited-stage small cell lung cancer and demonstrates distinct dosimetric characteristics. The current research findings are limited to the dosimetric level and further clinical trials are required for verification.</p>","PeriodicalId":32406,"journal":{"name":"Precision Radiation Oncology","volume":" ","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2026-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13570430/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Precision Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/pro6.70095","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Background and purpose: To evaluate the feasibility and dosimetric safety of integrating C-X-C motif chemokine receptor 4 (CXCR4)-targeted tracer 18F-AlF-NOTA-QHY-04 positron emission tomography imaging with biologically guided proton spatially fractionated radiotherapy (BG-pSFRT) for bulky limited-stage small cell lung cancer.
Materials and methods: Among 30 patients with bulky limited-stage small-cell lung cancer, a threshold range of 35%-40% of the maximum standard uptake value (SUVmax) showed optimal spatial correspondence with the computed tomography-based gross tumor volume (GTV). The median SUVmax was 6.96, and the Dice similarity coefficient ranged from 0.707 to 0.723. CXCR4-avid sub-volumes within GTV were characterized against the sub-targets of stereotactic body radiotherapy based partial tumor irradiation targeting hypoxic segments (SBRT-PATHY) and stereotactic centralized ablative radiation therapy (SCART). Dosimetric comparisons were performed between the BG-pSFRT and SCART plans (15-24 Gy per fraction in three fractions).
Results: CXCR4-defined sub-volumes with low thresholds in BG-pSFRT demonstrated spatial concordance with putative hypoxic sub-volumes in SBRT-PATHY, whereas higher SUVmax thresholds yielded multifocal distributions that exhibited spatial discordance relative to SCART, and these multifocal imaging-defined sub-volumes were targeted in BG-pSFRT for dose escalation. Compared to proton SCART, BG-pSFRT achieved greater high-dose (V80%), GTV coverage but slightly lower sub-volume conformity (89.04% vs. 95.55%; P < 0.001), and higher V5Gy and dose per fraction (P < 0.001). All organ-at-risk doses met the standard 3-fraction SBRT constraints.
Conclusions: CXCR4-targeted BG-pSFRT may be a dosimetrically feasible strategy for bulky limited-stage small cell lung cancer and demonstrates distinct dosimetric characteristics. The current research findings are limited to the dosimetric level and further clinical trials are required for verification.