C-X-C Motif Chemokine Receptor 4 (CXCR4)-Targeted Biologically Guided Proton Spatially Fractionated Radiotherapy for Bulky Limited-Stage Small Cell Lung Cancer.

IF 3.6 Q4 Medicine
Keru Pu, Tengxiang Li, Shengnan Xu, Xue Sha, Qingtao Qiu, Jinming Yu, Yong Yin, Jie Liu
{"title":"C-X-C Motif Chemokine Receptor 4 (CXCR4)-Targeted Biologically Guided Proton Spatially Fractionated Radiotherapy for Bulky Limited-Stage Small Cell Lung Cancer.","authors":"Keru Pu, Tengxiang Li, Shengnan Xu, Xue Sha, Qingtao Qiu, Jinming Yu, Yong Yin, Jie Liu","doi":"10.1002/pro6.70095","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>To evaluate the feasibility and dosimetric safety of integrating C-X-C motif chemokine receptor 4 (CXCR4)-targeted tracer <sup>1</sup> <sup>8</sup>F-AlF-NOTA-QHY-04 positron emission tomography imaging with biologically guided proton spatially fractionated radiotherapy (BG-pSFRT) for bulky limited-stage small cell lung cancer.</p><p><strong>Materials and methods: </strong>Among 30 patients with bulky limited-stage small-cell lung cancer, a threshold range of 35%-40% of the maximum standard uptake value (SUV<sub>max</sub>) showed optimal spatial correspondence with the computed tomography-based gross tumor volume (GTV). The median SUV<sub>max</sub> was 6.96, and the Dice similarity coefficient ranged from 0.707 to 0.723. CXCR4-avid sub-volumes within GTV were characterized against the sub-targets of stereotactic body radiotherapy based partial tumor irradiation targeting hypoxic segments (SBRT-PATHY) and stereotactic centralized ablative radiation therapy (SCART). Dosimetric comparisons were performed between the BG-pSFRT and SCART plans (15-24 Gy per fraction in three fractions).</p><p><strong>Results: </strong>CXCR4-defined sub-volumes with low thresholds in BG-pSFRT demonstrated spatial concordance with putative hypoxic sub-volumes in SBRT-PATHY, whereas higher SUV<sub>max</sub> thresholds yielded multifocal distributions that exhibited spatial discordance relative to SCART, and these multifocal imaging-defined sub-volumes were targeted in BG-pSFRT for dose escalation. Compared to proton SCART, BG-pSFRT achieved greater high-dose (V<sub>80%</sub>), GTV coverage but slightly lower sub-volume conformity (89.04% vs. 95.55%; <i>P</i> < 0.001), and higher V<sub>5Gy</sub> and dose per fraction (<i>P</i> < 0.001). All organ-at-risk doses met the standard 3-fraction SBRT constraints.</p><p><strong>Conclusions: </strong>CXCR4-targeted BG-pSFRT may be a dosimetrically feasible strategy for bulky limited-stage small cell lung cancer and demonstrates distinct dosimetric characteristics. The current research findings are limited to the dosimetric level and further clinical trials are required for verification.</p>","PeriodicalId":32406,"journal":{"name":"Precision Radiation Oncology","volume":" ","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2026-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13570430/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Precision Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/pro6.70095","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose: To evaluate the feasibility and dosimetric safety of integrating C-X-C motif chemokine receptor 4 (CXCR4)-targeted tracer 1 8F-AlF-NOTA-QHY-04 positron emission tomography imaging with biologically guided proton spatially fractionated radiotherapy (BG-pSFRT) for bulky limited-stage small cell lung cancer.

Materials and methods: Among 30 patients with bulky limited-stage small-cell lung cancer, a threshold range of 35%-40% of the maximum standard uptake value (SUVmax) showed optimal spatial correspondence with the computed tomography-based gross tumor volume (GTV). The median SUVmax was 6.96, and the Dice similarity coefficient ranged from 0.707 to 0.723. CXCR4-avid sub-volumes within GTV were characterized against the sub-targets of stereotactic body radiotherapy based partial tumor irradiation targeting hypoxic segments (SBRT-PATHY) and stereotactic centralized ablative radiation therapy (SCART). Dosimetric comparisons were performed between the BG-pSFRT and SCART plans (15-24 Gy per fraction in three fractions).

Results: CXCR4-defined sub-volumes with low thresholds in BG-pSFRT demonstrated spatial concordance with putative hypoxic sub-volumes in SBRT-PATHY, whereas higher SUVmax thresholds yielded multifocal distributions that exhibited spatial discordance relative to SCART, and these multifocal imaging-defined sub-volumes were targeted in BG-pSFRT for dose escalation. Compared to proton SCART, BG-pSFRT achieved greater high-dose (V80%), GTV coverage but slightly lower sub-volume conformity (89.04% vs. 95.55%; P < 0.001), and higher V5Gy and dose per fraction (P < 0.001). All organ-at-risk doses met the standard 3-fraction SBRT constraints.

Conclusions: CXCR4-targeted BG-pSFRT may be a dosimetrically feasible strategy for bulky limited-stage small cell lung cancer and demonstrates distinct dosimetric characteristics. The current research findings are limited to the dosimetric level and further clinical trials are required for verification.

C-X-C基序趋化因子受体4 (CXCR4)靶向生物引导质子空间分割放疗治疗大体积有限期小细胞肺癌
背景与目的:评价C-X-C基序趋化因子受体4 (CXCR4)靶向示踪剂1 8f - alf - nota - qhyy -04正电子发射断层成像与生物引导质子空间分割放疗(BG-pSFRT)结合治疗大体积有限期小细胞肺癌的可行性和剂量学安全性。材料与方法:在30例体积较大的有限期小细胞肺癌患者中,阈值范围为最大标准摄取值(SUVmax)的35%-40%与基于计算机断层扫描的总肿瘤体积(GTV)具有最佳的空间对应关系。SUVmax中位数为6.96,Dice相似系数为0.707 ~ 0.723。GTV内的CXCR4-avid亚体积针对基于立体定向体放疗的局部肿瘤缺氧段照射(SBRT-PATHY)和立体定向集中消融放射治疗(SCART)的亚靶标进行了表征。在BG-pSFRT和SCART计划之间进行剂量学比较(三个部分中每个部分15-24 Gy)。结果:在BG-pSFRT中,cxcr4定义的低阈值亚体积与SBRT-PATHY中假定的缺氧亚体积在空间上一致,而较高的SUVmax阈值产生的多灶分布相对于SCART表现出空间不一致,这些多灶成像定义的亚体积在BG-pSFRT中被靶向进行剂量递增。与质子SCART相比,BG-pSFRT具有更高的高剂量(V80%), GTV覆盖率,但亚体积符合性略低(89.04% vs. 95.55%; P < 0.001), V5Gy和每分数剂量更高(P < 0.001)。所有器官风险剂量均符合标准的3分SBRT限制。结论:cxcr4靶向的BG-pSFRT可能是一种剂量学上可行的治疗大体积有限期小细胞肺癌的策略,并具有不同的剂量学特征。目前的研究结果仅限于剂量学水平,需要进一步的临床试验来验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Precision Radiation Oncology
Precision Radiation Oncology Medicine-Oncology
CiteScore
1.20
自引率
0.00%
发文量
32
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书