{"title":"Copper–Sodium Lignosulfonate Antifouling-Coated Ion-Selective Electrodes for Reliable Long-Term Ammonium Monitoring toward Data-Driven Wastewater Control","authors":"Yun Zhou, Yinuo Yang, Felio Perez, Xiaolei Huang, Yuankai Huang","doi":"10.1021/acsestengg.6c00476","DOIUrl":null,"url":null,"abstract":"<p>Ammonium (NH<sub>4</sub><sup>+</sup>) monitoring is essential\r\nfor\r\nprocess control and effluent compliance in wastewater treatment, but\r\nconventional grab sampling provides delayed, discrete measurements\r\nthat cannot capture rapid concentration fluctuations. Solid-state\r\nion-selective electrodes (S-ISEs) are promising for continuous real-time\r\nmonitoring, but long-term deployment is limited by membrane biofouling.\r\nHere, we developed a Cu<sup>2+</sup>-sodium lignosulfonate (Cu-SLS)\r\nantifouling coating for NH<sub>4</sub><sup>+</sup> S-ISEs that simultaneously\r\nreduces biofouling and improves interfacial stability. By combining\r\nthe hydrophilic hydration effect of SLS with the antimicrobial activity\r\nof coordinated Cu<sup>2+</sup>, the coating provided a more stable\r\nsensing interface under wastewater-relevant conditions. A systematic\r\n3 × 3 formulation screening identified Cu0.10-SLS0.25 coating\r\nas the optimal configuration, retaining a near-Nernstian sensitivity\r\nof 56.5 mV/dec, a response time of 5.5 s, and a detection limit of\r\n3.2 × 10<sup>–6</sup> M. The enhanced Cu retention of\r\nCu0.10-SLS0.25 during aqueous exposure was consistent with stronger\r\nCu(II)-sulfonate interactions and its improved long-term sensing stability.\r\nIn a 14-day real wastewater deployment, Cu0.10-SLS0.25 achieved a\r\nmean absolute error of 1.24 mg/L and successfully captured a simulated\r\nNH<sub>4</sub><sup>+</sup> shock event on Day 11, with minimal surface\r\nbiofouling observed by posttest SEM. These results demonstrate a practical,\r\nmechanism-guided strategy for improving the reliability of long-term\r\nNH<sub>4</sub><sup>+</sup> monitoring in complex wastewater environments.</p>","PeriodicalId":7008,"journal":{"name":"ACS ES&T engineering","volume":"6 9","pages":"2606–2617"},"PeriodicalIF":6.3000,"publicationDate":"2026-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS ES&T engineering","FirstCategoryId":"1085","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsestengg.6c00476","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/10 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0
Abstract
Ammonium (NH4+) monitoring is essential
for
process control and effluent compliance in wastewater treatment, but
conventional grab sampling provides delayed, discrete measurements
that cannot capture rapid concentration fluctuations. Solid-state
ion-selective electrodes (S-ISEs) are promising for continuous real-time
monitoring, but long-term deployment is limited by membrane biofouling.
Here, we developed a Cu2+-sodium lignosulfonate (Cu-SLS)
antifouling coating for NH4+ S-ISEs that simultaneously
reduces biofouling and improves interfacial stability. By combining
the hydrophilic hydration effect of SLS with the antimicrobial activity
of coordinated Cu2+, the coating provided a more stable
sensing interface under wastewater-relevant conditions. A systematic
3 × 3 formulation screening identified Cu0.10-SLS0.25 coating
as the optimal configuration, retaining a near-Nernstian sensitivity
of 56.5 mV/dec, a response time of 5.5 s, and a detection limit of
3.2 × 10–6 M. The enhanced Cu retention of
Cu0.10-SLS0.25 during aqueous exposure was consistent with stronger
Cu(II)-sulfonate interactions and its improved long-term sensing stability.
In a 14-day real wastewater deployment, Cu0.10-SLS0.25 achieved a
mean absolute error of 1.24 mg/L and successfully captured a simulated
NH4+ shock event on Day 11, with minimal surface
biofouling observed by posttest SEM. These results demonstrate a practical,
mechanism-guided strategy for improving the reliability of long-term
NH4+ monitoring in complex wastewater environments.
期刊介绍:
ACS ES&T Engineering publishes impactful research and review articles across all realms of environmental technology and engineering, employing a rigorous peer-review process. As a specialized journal, it aims to provide an international platform for research and innovation, inviting contributions on materials technologies, processes, data analytics, and engineering systems that can effectively manage, protect, and remediate air, water, and soil quality, as well as treat wastes and recover resources.
The journal encourages research that supports informed decision-making within complex engineered systems and is grounded in mechanistic science and analytics, describing intricate environmental engineering systems. It considers papers presenting novel advancements, spanning from laboratory discovery to field-based application. However, case or demonstration studies lacking significant scientific advancements and technological innovations are not within its scope.