Scalable Poly(organosiloxane)-Modified Air Filtration Media for Reducing Indoor Airborne Transmission of SARS-CoV-2 and Other Contagions

IF 6.3 Q1 ENGINEERING, ENVIRONMENTAL
ACS ES&T engineering Pub Date : 2026-09-11 Epub Date: 2026-07-08 DOI:10.1021/acsestengg.6c00372
Amirhomayoon Paydar, Surendra Maharjan, Alexander J. Wang, Eileen Mellon, Jerry Gates, Bryan Hlavinka, Alex J. Taylor, Michael Curran, Jakelin Gutierrez, Layla Pham, Christopher Taylor, Kenneth Russell, Seamus A. Curran
{"title":"Scalable Poly(organosiloxane)-Modified Air Filtration Media for Reducing Indoor Airborne Transmission of SARS-CoV-2 and Other Contagions","authors":"Amirhomayoon Paydar,&nbsp;Surendra Maharjan,&nbsp;Alexander J. Wang,&nbsp;Eileen Mellon,&nbsp;Jerry Gates,&nbsp;Bryan Hlavinka,&nbsp;Alex J. Taylor,&nbsp;Michael Curran,&nbsp;Jakelin Gutierrez,&nbsp;Layla Pham,&nbsp;Christopher Taylor,&nbsp;Kenneth Russell,&nbsp;Seamus A. Curran","doi":"10.1021/acsestengg.6c00372","DOIUrl":null,"url":null,"abstract":"<p>Mounting empirical evidence supporting the notion of\r\nairborne transmission\r\nof communicable infectious diseases, such as COVID-19, continues to\r\nshift the consensus toward increasing indoor air quality safety standards\r\nin common spaces. Airborne viral transmission is particularly problematic\r\nin rationally designing next-generation heating, ventilation, and\r\nair-conditioning (HVAC) system technologies to cost-effectively remove\r\nairborne biological contaminants from shared indoor environments.\r\nHolistic strategies for managing indoor air quality in shared commercial\r\nspaces often rely on HVAC disinfection technologies (e.g., ultraviolet\r\nlight-C irradiation and bipolar ionization) or the use of functionalized\r\nair filters such as resistively heated Ni-foam filters and Ag nanocluster/silica\r\nnanocomposite coatings, both of which are costly to implement and\r\nmaintain. Many existing HVAC systems are unable to accommodate simple\r\noperational changes (e.g., static pressure, incident air temperature,\r\nand outdoor-to-recirculated air ratios) while maintaining acceptable\r\nset points and energy efficiency. This work is the first report on\r\na scalable SARS-CoV-2-capturing waterborne poly(organosiloxane)-based\r\ncoating, named microbial and viral transmission resistance (MVTR),\r\nthat is applied directly to HVAC air filtration media as a retrofit\r\nwithout adversely affecting breathability or static pressure upon\r\ncuring/cross-linking. Real-time quantitative polymerase chain reaction\r\nstudies demonstrate that MVTR-treated MERV-8 air filters are more\r\neffective at filtering a challenge aerosol of thermally inactivated\r\nSARS-CoV-2 virions than untreated MERV-13 air filters. MVTR reduces\r\nconcentrations of airborne SARS-CoV-2 using lower MERV-rated air filters\r\nwhile preserving energy efficiency without imposing operational restrictions\r\non HVAC systems and is another preventive countermeasure against indoor\r\ncontagion, synergistically augmenting best hygiene practices, social\r\ndistancing, disinfectants, virucidal nanomaterials, novel vaccines,\r\nand existing antiviral pharmaceuticals.</p>","PeriodicalId":7008,"journal":{"name":"ACS ES&T engineering","volume":"6 9","pages":"2461–2475"},"PeriodicalIF":6.3000,"publicationDate":"2026-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS ES&T engineering","FirstCategoryId":"1085","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsestengg.6c00372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Mounting empirical evidence supporting the notion of airborne transmission of communicable infectious diseases, such as COVID-19, continues to shift the consensus toward increasing indoor air quality safety standards in common spaces. Airborne viral transmission is particularly problematic in rationally designing next-generation heating, ventilation, and air-conditioning (HVAC) system technologies to cost-effectively remove airborne biological contaminants from shared indoor environments. Holistic strategies for managing indoor air quality in shared commercial spaces often rely on HVAC disinfection technologies (e.g., ultraviolet light-C irradiation and bipolar ionization) or the use of functionalized air filters such as resistively heated Ni-foam filters and Ag nanocluster/silica nanocomposite coatings, both of which are costly to implement and maintain. Many existing HVAC systems are unable to accommodate simple operational changes (e.g., static pressure, incident air temperature, and outdoor-to-recirculated air ratios) while maintaining acceptable set points and energy efficiency. This work is the first report on a scalable SARS-CoV-2-capturing waterborne poly(organosiloxane)-based coating, named microbial and viral transmission resistance (MVTR), that is applied directly to HVAC air filtration media as a retrofit without adversely affecting breathability or static pressure upon curing/cross-linking. Real-time quantitative polymerase chain reaction studies demonstrate that MVTR-treated MERV-8 air filters are more effective at filtering a challenge aerosol of thermally inactivated SARS-CoV-2 virions than untreated MERV-13 air filters. MVTR reduces concentrations of airborne SARS-CoV-2 using lower MERV-rated air filters while preserving energy efficiency without imposing operational restrictions on HVAC systems and is another preventive countermeasure against indoor contagion, synergistically augmenting best hygiene practices, social distancing, disinfectants, virucidal nanomaterials, novel vaccines, and existing antiviral pharmaceuticals.

可伸缩聚有机硅氧烷改性空气过滤介质用于减少SARS-CoV-2和其他传染病的室内空气传播
越来越多的经验证据支持COVID-19等传染性传染病通过空气传播的概念,这继续将共识转向提高公共空间的室内空气质量安全标准。在合理设计下一代供暖、通风和空调(HVAC)系统技术以经济有效地从共享室内环境中去除空气传播的生物污染物时,空气传播病毒尤其成问题。管理共享商业空间室内空气质量的整体策略通常依赖于暖通空调消毒技术(例如,紫外线- c照射和双极电离)或使用功能化空气过滤器,如电阻加热镍泡沫过滤器和银纳米簇/硅复合涂层,这两种方法的实施和维护成本都很高。许多现有的暖通空调系统无法适应简单的操作变化(例如,静压,入射空气温度和室外与再循环空气的比率),同时保持可接受的点和能源效率。这项工作是关于可扩展的sars - cov -2捕获水性聚有机硅氧烷涂层的第一份报告,称为微生物和病毒传播抗性(MVTR),该涂层直接应用于HVAC空气过滤介质作为改造,而不会对透气性或固化/交联时的静压产生不利影响。实时定量聚合酶链反应研究表明,与未经处理的MERV-13空气过滤器相比,mvrr处理的MERV-8空气过滤器在过滤热灭活的sars - cov -2病毒粒子的挑战气溶胶方面更有效。MVTR使用较低的merv额定空气过滤器降低空气中SARS-CoV-2的浓度,同时保持能源效率,而不会对暖通空调系统施加操作限制,是防止室内感染的另一种预防措施,协同增强了最佳卫生习惯、社交距离、消毒剂、抗病毒纳米材料、新型疫苗和现有抗病毒药物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS ES&T engineering
ACS ES&T engineering ENGINEERING, ENVIRONMENTAL-
CiteScore
8.50
自引率
0.00%
发文量
0
期刊介绍: ACS ES&T Engineering publishes impactful research and review articles across all realms of environmental technology and engineering, employing a rigorous peer-review process. As a specialized journal, it aims to provide an international platform for research and innovation, inviting contributions on materials technologies, processes, data analytics, and engineering systems that can effectively manage, protect, and remediate air, water, and soil quality, as well as treat wastes and recover resources. The journal encourages research that supports informed decision-making within complex engineered systems and is grounded in mechanistic science and analytics, describing intricate environmental engineering systems. It considers papers presenting novel advancements, spanning from laboratory discovery to field-based application. However, case or demonstration studies lacking significant scientific advancements and technological innovations are not within its scope. Contributions containing experimental and/or theoretical methods, rooted in engineering principles and integrated with knowledge from other disciplines, are welcomed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书