{"title":"Stent retrievers for acute ischemic stroke: technological advances, clinical applications, and future perspectives.","authors":"Zhiyuan Xie, Zixuan Wang, Peijie Fu, ZhiXing Shi, Zixuan Zhuang, Huiqin Wang, Yuanyuan Xiang, Xiaoping Yin, Zhiying Chen","doi":"10.1007/s00415-026-14126-z","DOIUrl":null,"url":null,"abstract":"<p><p>Acute ischemic stroke caused by large vessel occlusion remains a leading cause of death and disability despite established reperfusion therapies. Although stent retriever-based thrombectomy has become the standard of care, outcomes are still constrained in complex occlusions and anatomically challenging cases. This review summarizes and critically appraises recent advances in stent retriever technology, thrombectomy techniques, and evidence expansion in acute ischemic stroke. Device development has progressed from first-generation retrieval systems to self-expanding stent retrievers and recent integrated retrieval-protection platforms, leading to improved clot engagement, higher first-pass reperfusion, and reduced distal embolization. Parallel refinements in procedural strategies including combined aspiration catheters, balloon guide catheters, and dual-stent techniques have enhanced recanalization efficiency and procedural control. Clinical evidence has extended thrombectomy indications beyond conventional time windows to include posterior circulation occlusion, large infarct cores, and selected medium/distal vessel occlusions under imaging-guided selection. Advances in thrombus characterization, biomaterials, surface engineering, and territory-specific devices are further enabling more tailored mechanical approaches. Nevertheless, fibrin-rich resistant thrombi, embolic complications, vascular injury, and limited high-level evidence for emerging devices remain unresolved challenges. Ongoing integration of engineering innovation and clinical data is expected to support more individualized and safer thrombectomy strategies with improved functional outcomes.</p>","PeriodicalId":16558,"journal":{"name":"Journal of Neurology","volume":"273 10","pages":""},"PeriodicalIF":5.4000,"publicationDate":"2026-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neurology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00415-026-14126-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Acute ischemic stroke caused by large vessel occlusion remains a leading cause of death and disability despite established reperfusion therapies. Although stent retriever-based thrombectomy has become the standard of care, outcomes are still constrained in complex occlusions and anatomically challenging cases. This review summarizes and critically appraises recent advances in stent retriever technology, thrombectomy techniques, and evidence expansion in acute ischemic stroke. Device development has progressed from first-generation retrieval systems to self-expanding stent retrievers and recent integrated retrieval-protection platforms, leading to improved clot engagement, higher first-pass reperfusion, and reduced distal embolization. Parallel refinements in procedural strategies including combined aspiration catheters, balloon guide catheters, and dual-stent techniques have enhanced recanalization efficiency and procedural control. Clinical evidence has extended thrombectomy indications beyond conventional time windows to include posterior circulation occlusion, large infarct cores, and selected medium/distal vessel occlusions under imaging-guided selection. Advances in thrombus characterization, biomaterials, surface engineering, and territory-specific devices are further enabling more tailored mechanical approaches. Nevertheless, fibrin-rich resistant thrombi, embolic complications, vascular injury, and limited high-level evidence for emerging devices remain unresolved challenges. Ongoing integration of engineering innovation and clinical data is expected to support more individualized and safer thrombectomy strategies with improved functional outcomes.
期刊介绍:
The Journal of Neurology is an international peer-reviewed journal which provides a source for publishing original communications and reviews on clinical neurology covering the whole field.
In addition, Letters to the Editors serve as a forum for clinical cases and the exchange of ideas which highlight important new findings. A section on Neurological progress serves to summarise the major findings in certain fields of neurology. Commentaries on new developments in clinical neuroscience, which may be commissioned or submitted, are published as editorials.
Every neurologist interested in the current diagnosis and treatment of neurological disorders needs access to the information contained in this valuable journal.