Noninvasive Estimation of Post-TIPS Portosystemic Pressure Gradient Using 4D Flow MRI Relative Pressure Mapping and CT-Based CFD Driven by MRI-Derived Inflow: A Retrospective Validation Study.
{"title":"Noninvasive Estimation of Post-TIPS Portosystemic Pressure Gradient Using 4D Flow MRI Relative Pressure Mapping and CT-Based CFD Driven by MRI-Derived Inflow: A Retrospective Validation Study.","authors":"Xiaorong Chen, Xiaoxian Yang, Linhao Hu, Jianji Dai, Jiangfeng Pan, Qing Liu, Suping Wang, Meiling Hu, Dingjun Wang, Tianqi Wang, Haojia Qu, Xinyang Ge, Xiaogang Hu","doi":"10.1016/j.jocmr.2026.102797","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Post-transjugular intrahepatic portosystemic shunt (TIPS) portosystemic pressure gradient (PPG) is invasive and a key hemodynamic marker for post-TIPS management. Longitudinal monitoring motivates development of reliable noninvasive alternatives.</p><p><strong>Objective: </strong>To validate the performance of non-invasively assessing post-TIPS PPG using four-dimensional flow MRI (MRI_PPG), CT (CT_PPG) (driven by MRI-derived inflow), and concordance with invasively measured PPG.</p><p><strong>Materials and methods: </strong>This retrospective study included 31 post-TIPS patients who underwent PPG measurement and 4D flow MRI within 7 days of the invasive measurement, a subset (n=18) underwent abdominal CT. MRI_PPG was computed from 4D flow MRI velocity fields using relative pressure mapping. For CT-Based CFD Driven by MRI-Derived Inflow, portal venous phase CT was segmented to create patient-specific geometry, and 4D flow MRI-derived inflow at the main portal vein was used to define three inlet protocols: (i) time-averaged peak velocity (CT_PPG1), (ii) time-resolved flow waveform (CT_PPG2), and (iii) time-averaged mean velocity (CT_PPG3). Correlation and agreement with PPG were assessed, and classification performance for clinically relevant PPG ranges was evaluated.</p><p><strong>Results: </strong>In the full cohort (n=31), MRI_PPG (11.23±4.74mmHg) correlated strongly with PPG (11.84±4.72mmHg) (r=0.94, P<0.01) and showed excellent agreement (ICC=0.94), with Bland-Altman bias of 0.61mmHg and limits of agreement (LoA) from -2.70 to 3.92mmHg. In the CT subset (n=18), MRI_PPG remained highly correlated (r=0.91, P<0.01) and showed good agreement (ICC=0.90; bias 0.80mmHg; LoA -3.04 to 4.63mmHg). Among CT‑based estimates, CT_PPG1 demonstrated the best performance (12.47±5.31mmHg; r=0.79, P<0.01; ICC=0.77; bias -0.42mmHg; LoA -6.84 to 6.00mmHg). Three‑range classification accuracy in the CT subset was 77.78% for MRI_PPG, compared with 66.67% for CT_PPG1, 50% for CT_PPG2, and 61.11% for CT_PPG3.</p><p><strong>Conclusion: </strong>Both MRI_PPG and CT-PPG CFD estimates are feasible noninvasive approaches for post-TIPS hemodynamic assessment. 4D flow MRI-derived relative pressure mapping demonstrated superior performance, supporting its potential value for post-TIPS follow-up.</p>","PeriodicalId":15221,"journal":{"name":"Journal of Cardiovascular Magnetic Resonance","volume":" ","pages":"102797"},"PeriodicalIF":5.0000,"publicationDate":"2026-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Magnetic Resonance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocmr.2026.102797","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Post-transjugular intrahepatic portosystemic shunt (TIPS) portosystemic pressure gradient (PPG) is invasive and a key hemodynamic marker for post-TIPS management. Longitudinal monitoring motivates development of reliable noninvasive alternatives.
Objective: To validate the performance of non-invasively assessing post-TIPS PPG using four-dimensional flow MRI (MRI_PPG), CT (CT_PPG) (driven by MRI-derived inflow), and concordance with invasively measured PPG.
Materials and methods: This retrospective study included 31 post-TIPS patients who underwent PPG measurement and 4D flow MRI within 7 days of the invasive measurement, a subset (n=18) underwent abdominal CT. MRI_PPG was computed from 4D flow MRI velocity fields using relative pressure mapping. For CT-Based CFD Driven by MRI-Derived Inflow, portal venous phase CT was segmented to create patient-specific geometry, and 4D flow MRI-derived inflow at the main portal vein was used to define three inlet protocols: (i) time-averaged peak velocity (CT_PPG1), (ii) time-resolved flow waveform (CT_PPG2), and (iii) time-averaged mean velocity (CT_PPG3). Correlation and agreement with PPG were assessed, and classification performance for clinically relevant PPG ranges was evaluated.
Results: In the full cohort (n=31), MRI_PPG (11.23±4.74mmHg) correlated strongly with PPG (11.84±4.72mmHg) (r=0.94, P<0.01) and showed excellent agreement (ICC=0.94), with Bland-Altman bias of 0.61mmHg and limits of agreement (LoA) from -2.70 to 3.92mmHg. In the CT subset (n=18), MRI_PPG remained highly correlated (r=0.91, P<0.01) and showed good agreement (ICC=0.90; bias 0.80mmHg; LoA -3.04 to 4.63mmHg). Among CT‑based estimates, CT_PPG1 demonstrated the best performance (12.47±5.31mmHg; r=0.79, P<0.01; ICC=0.77; bias -0.42mmHg; LoA -6.84 to 6.00mmHg). Three‑range classification accuracy in the CT subset was 77.78% for MRI_PPG, compared with 66.67% for CT_PPG1, 50% for CT_PPG2, and 61.11% for CT_PPG3.
Conclusion: Both MRI_PPG and CT-PPG CFD estimates are feasible noninvasive approaches for post-TIPS hemodynamic assessment. 4D flow MRI-derived relative pressure mapping demonstrated superior performance, supporting its potential value for post-TIPS follow-up.
期刊介绍:
Journal of Cardiovascular Magnetic Resonance (JCMR) publishes high-quality articles on all aspects of basic, translational and clinical research on the design, development, manufacture, and evaluation of cardiovascular magnetic resonance (CMR) methods applied to the cardiovascular system. Topical areas include, but are not limited to:
New applications of magnetic resonance to improve the diagnostic strategies, risk stratification, characterization and management of diseases affecting the cardiovascular system.
New methods to enhance or accelerate image acquisition and data analysis.
Results of multicenter, or larger single-center studies that provide insight into the utility of CMR.
Basic biological perceptions derived by CMR methods.