Successful Endoscopic Treatment of Walled-Off Necrosis With Complex Quadruple Fistulas Among the Necrotic Cavity, Stomach, Duodenum, and Common Bile Duct

IF 1.5 Q4 GASTROENTEROLOGY & HEPATOLOGY
DEN open Pub Date : 2026-09-11 DOI:10.1002/deo2.70432
Shuhei Shibata, Yotaro Iino, Jo Kurosawa, Ken Uchida, Daiki Takahashi, Yuya Yokoyama, Hiroshi Ohyama, Futoshi Hirai, Michikazu Abe, Jun Kato
{"title":"Successful Endoscopic Treatment of Walled-Off Necrosis With Complex Quadruple Fistulas Among the Necrotic Cavity, Stomach, Duodenum, and Common Bile Duct","authors":"Shuhei Shibata,&nbsp;Yotaro Iino,&nbsp;Jo Kurosawa,&nbsp;Ken Uchida,&nbsp;Daiki Takahashi,&nbsp;Yuya Yokoyama,&nbsp;Hiroshi Ohyama,&nbsp;Futoshi Hirai,&nbsp;Michikazu Abe,&nbsp;Jun Kato","doi":"10.1002/deo2.70432","DOIUrl":null,"url":null,"abstract":"<p>We report an extremely rare case of duodenal bulb perforation caused by a double-pigtail plastic stent placed for walled-off necrosis (WON), coexisting with a biliary fistula to the WON and a choledochoduodenal fistula, all successfully managed with endoscopic treatment alone. A 61-year-old woman developed severe gallstone pancreatitis and underwent endoscopic ultrasound-guided transmural drainage for WON with placement of a lumen-apposing metal stent and a double-pigtail plastic stent. After repeated endoscopic necrosectomy, the metal stent was removed and the plastic stent remained in place. Contrast leakage from the WON into the bile duct was detected, and a biliary stent was inadvertently deployed through a choledochoduodenal fistula. Two hundred thirty-seven days after plastic stent placement, endoscopy revealed a duodenal bulb perforation with purulent discharge. The plastic stent was removed, and the gastric fistula was closed using endoscopic hand-suturing. After spontaneous closure of the stent-induced duodenal perforation was confirmed, the biliary stent placed through the choledochoduodenal fistula was removed and a new stent was inserted through the papilla of Vater, resulting in closure of the choledochoduodenal fistula. Complete closure of all fistulas was confirmed 516 days after the initial hospitalization. This case demonstrates that complex fistulas associated with WON can be successfully treated without surgical intervention.</p>","PeriodicalId":93973,"journal":{"name":"DEN open","volume":"7 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2026-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/deo2.70432","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"DEN open","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/deo2.70432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

We report an extremely rare case of duodenal bulb perforation caused by a double-pigtail plastic stent placed for walled-off necrosis (WON), coexisting with a biliary fistula to the WON and a choledochoduodenal fistula, all successfully managed with endoscopic treatment alone. A 61-year-old woman developed severe gallstone pancreatitis and underwent endoscopic ultrasound-guided transmural drainage for WON with placement of a lumen-apposing metal stent and a double-pigtail plastic stent. After repeated endoscopic necrosectomy, the metal stent was removed and the plastic stent remained in place. Contrast leakage from the WON into the bile duct was detected, and a biliary stent was inadvertently deployed through a choledochoduodenal fistula. Two hundred thirty-seven days after plastic stent placement, endoscopy revealed a duodenal bulb perforation with purulent discharge. The plastic stent was removed, and the gastric fistula was closed using endoscopic hand-suturing. After spontaneous closure of the stent-induced duodenal perforation was confirmed, the biliary stent placed through the choledochoduodenal fistula was removed and a new stent was inserted through the papilla of Vater, resulting in closure of the choledochoduodenal fistula. Complete closure of all fistulas was confirmed 516 days after the initial hospitalization. This case demonstrates that complex fistulas associated with WON can be successfully treated without surgical intervention.

内窥镜成功治疗坏死腔、胃、十二指肠和胆总管内复杂的四重瘘管伴壁闭塞性坏死
我们报告一例极为罕见的十二指肠球穿孔病例,该病例是由于放置双尾塑料支架治疗壁外坏死(WON)而引起的,并伴有通往WON的胆瘘和胆总管十二指肠瘘,所有病例均成功地通过内镜治疗。一名61岁的女性患了严重的胆石性胰腺炎,并接受了超声内镜引导下的经壁引流术,放置了一个腔内金属支架和一个双尾状塑料支架。经多次内窥镜切除后,金属支架被移除,塑料支架保留在原位。发现对比剂从WON渗漏到胆管,无意中通过胆总管十二指肠瘘部署了胆道支架。塑料支架置入后237天,内镜检查发现十二指肠球穿孔伴脓性排出物。取出塑料支架,内镜下手工缝合胃瘘。确认支架所致十二指肠穿孔自行闭合后,取出经胆总管十二指肠瘘置入的胆道支架,经Vater乳头置入新的支架,使胆总管十二指肠瘘闭合。初次住院后516天确认所有瘘管完全闭合。本病例表明,复杂的瘘管相关的WON可以成功地治疗无需手术干预。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书