Safety and Efficacy of the Extravascular Implantable Cardioverter-Defibrillator (EV-ICD) in Japanese Patients: Final Results From the EV ICD Japan Study.

IF 2.3
Circulation reports Pub Date : 2026-08-04 eCollection Date: 2026-09-10 DOI:10.1253/circrep.CR-26-0131
Mitsuru Wada, Nobuhiro Nishii, Kohei Ishibashi, Christopher Wiggenhorn, Takuto Yamamoto, Kengo Kusano
{"title":"Safety and Efficacy of the Extravascular Implantable Cardioverter-Defibrillator (EV-ICD) in Japanese Patients: Final Results From the EV ICD Japan Study.","authors":"Mitsuru Wada, Nobuhiro Nishii, Kohei Ishibashi, Christopher Wiggenhorn, Takuto Yamamoto, Kengo Kusano","doi":"10.1253/circrep.CR-26-0131","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The extravascular implantable cardioverter-defibrillator (EV-ICD) has proven efficacy and a low complication rate in global populations, but data from Japanese patients is limited. We report the safety and efficacy of the EV-ICD system in a Japanese cohort through 12 months of follow-up.</p><p><strong>Methods and results: </strong>Patients from Japan with a Class I or IIa indication for a single-chamber ICD were enrolled and implanted with the EV-ICD system. Defibrillation success was determined following implant. System programming changes, device electrical performance, freedom from major system- or procedure-related complications through 12 months post-implant, and follow-up status at all visits were assessed. From February to September 2023, 14 patients (12 males, 2 females) were enrolled and successfully implanted across 2 sites (age: 53.6±14.7 years; left ventricular ejection fraction: 52.6±15.6%; secondary prevention: 42.9%). Defibrillation testing was successful in all patients (14/14, 100%). At 2 weeks and 12 months, freedom from major system- and/or procedure-related complications was 92.9% and 85.7%, respectively. One patient received 7 appropriate shocks that were successful in terminating the arrhythmia. There were no inappropriate shocks delivered, and a single inappropriate antitachycardia pacing therapy was delivered through follow-up.</p><p><strong>Conclusions: </strong>The EV-ICD system was safely implanted and effective at terminating both induced and spontaneous ventricular arrhythmias in a small cohort of Japanese patients.</p>","PeriodicalId":94305,"journal":{"name":"Circulation reports","volume":"8 9","pages":"1396-1403"},"PeriodicalIF":2.3000,"publicationDate":"2026-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13558269/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1253/circrep.CR-26-0131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/10 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The extravascular implantable cardioverter-defibrillator (EV-ICD) has proven efficacy and a low complication rate in global populations, but data from Japanese patients is limited. We report the safety and efficacy of the EV-ICD system in a Japanese cohort through 12 months of follow-up.

Methods and results: Patients from Japan with a Class I or IIa indication for a single-chamber ICD were enrolled and implanted with the EV-ICD system. Defibrillation success was determined following implant. System programming changes, device electrical performance, freedom from major system- or procedure-related complications through 12 months post-implant, and follow-up status at all visits were assessed. From February to September 2023, 14 patients (12 males, 2 females) were enrolled and successfully implanted across 2 sites (age: 53.6±14.7 years; left ventricular ejection fraction: 52.6±15.6%; secondary prevention: 42.9%). Defibrillation testing was successful in all patients (14/14, 100%). At 2 weeks and 12 months, freedom from major system- and/or procedure-related complications was 92.9% and 85.7%, respectively. One patient received 7 appropriate shocks that were successful in terminating the arrhythmia. There were no inappropriate shocks delivered, and a single inappropriate antitachycardia pacing therapy was delivered through follow-up.

Conclusions: The EV-ICD system was safely implanted and effective at terminating both induced and spontaneous ventricular arrhythmias in a small cohort of Japanese patients.

日本患者血管外植入式心律转复除颤器(EV-ICD)的安全性和有效性:EV-ICD日本研究的最终结果
背景:血管外植入式心律转复除颤器(EV-ICD)在全球人群中已被证明有效且并发症发生率低,但来自日本患者的数据有限。我们通过12个月的随访报告了EV-ICD系统在日本队列中的安全性和有效性。方法和结果:招募来自日本的单室ICD I类或IIa类指征患者并植入EV-ICD系统。除颤成功与否在植入后确定。评估系统编程变化、设备电气性能、植入后12个月无主要系统或手术相关并发症以及所有就诊的随访状态。2023年2 - 9月,共纳入14例患者(男12例,女2例),成功植入2个部位,年龄53.6±14.7岁,左室射血分数52.6±15.6%,二级预防:42.9%。除颤试验在所有患者中均成功(14/14,100%)。在2周和12个月时,主要系统和/或手术相关并发症的发生率分别为92.9%和85.7%。1例患者接受7次适当电击,成功终止心律失常。随访中未出现不适当的电击,仅给予单次不适当的抗心动过速起搏治疗。结论:在一小部分日本患者中,EV-ICD系统可安全植入并有效终止诱发性和自发性室性心律失常。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书