Device console programming in patients undergoing TAVI with preexisting cardiac implantable electronic devices: a practical guide.

IF 1.5 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
REC Interventional Cardiology Pub Date : 2026-01-20 eCollection Date: 2026-07-01 DOI:10.24875/RECICE.M25000561
Filippo Pensotti, Luis Jorge Garnacho, Mario García-Gómez, Akash Jain, Marcelo Rodríguez, Mauricio Zuñiga, María Sandín-Fuentes, Alberto Campo, Carlos Cortés-Villar, Sara Blasco, Luis Llamas-Fernández, Sofía Campillo, J Alberto San Román, Ignacio J Amat-Santos
{"title":"Device console programming in patients undergoing TAVI with preexisting cardiac implantable electronic devices: a practical guide.","authors":"Filippo Pensotti, Luis Jorge Garnacho, Mario García-Gómez, Akash Jain, Marcelo Rodríguez, Mauricio Zuñiga, María Sandín-Fuentes, Alberto Campo, Carlos Cortés-Villar, Sara Blasco, Luis Llamas-Fernández, Sofía Campillo, J Alberto San Román, Ignacio J Amat-Santos","doi":"10.24875/RECICE.M25000561","DOIUrl":null,"url":null,"abstract":"<p><p>Transcatheter aortic valve implantation (TAVI) is established as the standard of care for patients across all surgical risk profiles, with expanding indications in younger and lower-risk populations. A substantial proportion of patients eligible for TAVI have preexisting cardiac implantable electronic devices (CIED). Temporary transvenous right ventricular (RV) pacing is routinely used during TAVI to facilitate procedural safety but carries inherent risks, including RV perforation, cardiac tamponade, and lead dislodgement. Alternative pacing strategies, such as left ventricular pacing via the valve delivery guidewire, have been proposed to reduce procedural complications. In patients with a preexisting CIED, leveraging the implanted device for procedural pacing represents a rational and potentially safer option. However, its adoption remains limited, largely due to unfamiliarity with device-specific programming. This article provides a detailed, step-by-step practical guide for programming rapid ventricular pacing using the most widely encountered CIED platforms: Biotronik, Medtronic, Abbott/St. Jude, Sorin, and Boston Scientific. The specific programming pathways for each manufacturer are summarized to facilitate safe, effective, and reproducible implementation during TAVI.</p>","PeriodicalId":34295,"journal":{"name":"REC Interventional Cardiology","volume":"8 3","pages":"184-189"},"PeriodicalIF":1.5000,"publicationDate":"2026-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13532105/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"REC Interventional Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24875/RECICE.M25000561","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Transcatheter aortic valve implantation (TAVI) is established as the standard of care for patients across all surgical risk profiles, with expanding indications in younger and lower-risk populations. A substantial proportion of patients eligible for TAVI have preexisting cardiac implantable electronic devices (CIED). Temporary transvenous right ventricular (RV) pacing is routinely used during TAVI to facilitate procedural safety but carries inherent risks, including RV perforation, cardiac tamponade, and lead dislodgement. Alternative pacing strategies, such as left ventricular pacing via the valve delivery guidewire, have been proposed to reduce procedural complications. In patients with a preexisting CIED, leveraging the implanted device for procedural pacing represents a rational and potentially safer option. However, its adoption remains limited, largely due to unfamiliarity with device-specific programming. This article provides a detailed, step-by-step practical guide for programming rapid ventricular pacing using the most widely encountered CIED platforms: Biotronik, Medtronic, Abbott/St. Jude, Sorin, and Boston Scientific. The specific programming pathways for each manufacturer are summarized to facilitate safe, effective, and reproducible implementation during TAVI.

设备控制台编程患者接受TAVI与先前存在的心脏植入式电子设备:实用指南。
经导管主动脉瓣植入术(TAVI)被确立为所有手术风险患者的标准护理,并在年轻和低风险人群中扩大适应症。符合TAVI条件的患者中有相当大比例的患者先前存在心脏植入式电子装置(CIED)。临时经静脉右心室起搏是TAVI期间常规使用的方法,以确保手术安全性,但存在固有风险,包括右心室穿孔、心包填塞和导联脱位。其他起搏策略,如通过瓣膜输送导丝进行左心室起搏,已被提出以减少手术并发症。对于先前存在CIED的患者,利用植入装置进行程序性起搏是一种合理且可能更安全的选择。然而,它的采用仍然有限,主要是由于不熟悉特定于设备的编程。本文提供了一个详细的,一步一步的实用指南,使用最广泛遇到的CIED平台编程快速心室起搏:Biotronik, Medtronic, Abbott/St。裘德,索林和波士顿科学公司。总结了每个制造商的特定编程路径,以促进TAVI期间安全、有效和可重复的实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
REC Interventional Cardiology
REC Interventional Cardiology Medicine-Cardiology and Cardiovascular Medicine
CiteScore
3.10
自引率
28.60%
发文量
87
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书