A novel multi-aptamer electrospun nanofibrous membrane for simultaneous selective extraction of monoamine neurotransmitters and determination in biological samples by LC-MS.
{"title":"A novel multi-aptamer electrospun nanofibrous membrane for simultaneous selective extraction of monoamine neurotransmitters and determination in biological samples by LC-MS.","authors":"Xijia Zhang, Junfeng Qin, Chen Ma, Ningning Wang, Yufeng Li, Juanjuan Zhao, Dongsheng Li","doi":"10.1007/s00216-026-06777-8","DOIUrl":null,"url":null,"abstract":"<p><p>Dopamine (DA) and serotonin (5-HT) are key monoamine neurotransmitters, the sensitive determination of which in biological matrices is challenging owing to low concentrations and strong matrix interference. In this study, a multi-aptamer-functionalized electrospun membrane (MA-Au@PVP/PVDF) was developed by simultaneously immobilizing the DA aptamer (Apt-DA) and the 5-HT aptamer (Apt-5-HT) on the membrane surface via Au-S bonds. The membrane combines high specific surface area, good stability, and aptamer-based specificity, enabling simultaneous and selective extraction of DA and 5-HT from complex samples. The enriched analytes were subsequently quantified using liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-Q-TOF-MS). The maximum adsorption capacities of the MA-Au@PVP/PVDF membrane were 190.8 ng/cm<sup>2</sup> for 5-HT and 165.1 ng/cm<sup>2</sup> for DA, with the adsorption process fitting well to the Langmuir isotherm model (R<sup>2</sup> ≥ 0.99). Under optimized extraction conditions, the established method was thoroughly validated in both serum and urine matrices, exhibiting wide linear ranges (2.5-1000 ng/mL, R<sup>2</sup> ≥ 0.9905), low limits of quantification (LLOQ 2.5-10 ng/mL), satisfactory intra- and inter-day precision (RSD < 10.54%), and negligible matrix effects (86.37%-108.92%). The recoveries in serum and urine were 88.91%-103.22%, demonstrating its good broad applicability in different matrices. The proposed method was successfully applied to the determination of DA and 5-HT in human urine samples, providing a reliable and efficient pretreatment strategy for trace neurotransmitter analysis.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":" ","pages":""},"PeriodicalIF":4.1000,"publicationDate":"2026-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-026-06777-8","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Dopamine (DA) and serotonin (5-HT) are key monoamine neurotransmitters, the sensitive determination of which in biological matrices is challenging owing to low concentrations and strong matrix interference. In this study, a multi-aptamer-functionalized electrospun membrane (MA-Au@PVP/PVDF) was developed by simultaneously immobilizing the DA aptamer (Apt-DA) and the 5-HT aptamer (Apt-5-HT) on the membrane surface via Au-S bonds. The membrane combines high specific surface area, good stability, and aptamer-based specificity, enabling simultaneous and selective extraction of DA and 5-HT from complex samples. The enriched analytes were subsequently quantified using liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-Q-TOF-MS). The maximum adsorption capacities of the MA-Au@PVP/PVDF membrane were 190.8 ng/cm2 for 5-HT and 165.1 ng/cm2 for DA, with the adsorption process fitting well to the Langmuir isotherm model (R2 ≥ 0.99). Under optimized extraction conditions, the established method was thoroughly validated in both serum and urine matrices, exhibiting wide linear ranges (2.5-1000 ng/mL, R2 ≥ 0.9905), low limits of quantification (LLOQ 2.5-10 ng/mL), satisfactory intra- and inter-day precision (RSD < 10.54%), and negligible matrix effects (86.37%-108.92%). The recoveries in serum and urine were 88.91%-103.22%, demonstrating its good broad applicability in different matrices. The proposed method was successfully applied to the determination of DA and 5-HT in human urine samples, providing a reliable and efficient pretreatment strategy for trace neurotransmitter analysis.
期刊介绍:
Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.