An Ultrasensitive Fluorescent Immunoassay Based on R-CDs@SiO2 Nanoparticles for Detection of Cardiac Troponin I.

IF 3.5 4区 生物学 Q3 BIOCHEMISTRY & MOLECULAR BIOLOGY
Li Wang, Lei Li, Wei Chen, Mingcui Zhang
{"title":"An Ultrasensitive Fluorescent Immunoassay Based on R-CDs@SiO<sub>2</sub> Nanoparticles for Detection of Cardiac Troponin I.","authors":"Li Wang, Lei Li, Wei Chen, Mingcui Zhang","doi":"10.1007/s12010-026-05914-4","DOIUrl":null,"url":null,"abstract":"<p><p>Highly sensitive detection of cardiac troponin I (cTnI) is of great significance for the early diagnosis and prognosis assessment of acute myocardial infarction (AMI). Conventional single carbon dot fluorescent probes are inherently limited by weak fluorescence intensity, challenging biofunctionalization and unsatisfactory detection sensitivity. Herein, we report an immunoassay strategy based on red-emissive silica-encapsulated carbon dots (R-CDs@SiO<sub>2</sub>) for highly amplified fluorescence signals, significantly enhancing detection sensitivity and selectivity. Additionally, under optimized conditions, the method demonstrated the limit of detection of 0.005 ng/mL (n = 3) and achieved recovery rates ranging from 93.6% to 113.0%, indicating excellent accuracy. Additionally, we employed confocal fluorescence imaging to visualize and localize the distribution of cTnI within cardiomyocytes (H9C2) using R-CDs@SiO<sub>2</sub> conjugated antibodies as fluorescent probes. The fluorescent immunosensor was successfully utilized to assess cTnI levels in clinical serum specimens. The results were consistent with those obtained from commercially available enzyme-linked immunosorbent assay (ELISA) kits. This demonstrates that the proposed method provides a robust platform for clinical diagnosis of acute myocardial infarction.</p>","PeriodicalId":465,"journal":{"name":"Applied Biochemistry and Biotechnology","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2026-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Biochemistry and Biotechnology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s12010-026-05914-4","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Highly sensitive detection of cardiac troponin I (cTnI) is of great significance for the early diagnosis and prognosis assessment of acute myocardial infarction (AMI). Conventional single carbon dot fluorescent probes are inherently limited by weak fluorescence intensity, challenging biofunctionalization and unsatisfactory detection sensitivity. Herein, we report an immunoassay strategy based on red-emissive silica-encapsulated carbon dots (R-CDs@SiO2) for highly amplified fluorescence signals, significantly enhancing detection sensitivity and selectivity. Additionally, under optimized conditions, the method demonstrated the limit of detection of 0.005 ng/mL (n = 3) and achieved recovery rates ranging from 93.6% to 113.0%, indicating excellent accuracy. Additionally, we employed confocal fluorescence imaging to visualize and localize the distribution of cTnI within cardiomyocytes (H9C2) using R-CDs@SiO2 conjugated antibodies as fluorescent probes. The fluorescent immunosensor was successfully utilized to assess cTnI levels in clinical serum specimens. The results were consistent with those obtained from commercially available enzyme-linked immunosorbent assay (ELISA) kits. This demonstrates that the proposed method provides a robust platform for clinical diagnosis of acute myocardial infarction.

基于R-CDs@SiO2纳米颗粒的超灵敏荧光免疫分析法检测心肌肌钙蛋白I。
高灵敏度检测心肌肌钙蛋白I (cTnI)对急性心肌梗死(AMI)的早期诊断和预后评估具有重要意义。传统的单碳点荧光探针存在荧光强度弱、生物功能化困难和检测灵敏度不理想等缺陷。在此,我们报告了一种基于红发射二氧化硅封装碳点(R-CDs@SiO2)的免疫分析策略,用于高度放大的荧光信号,显着提高了检测灵敏度和选择性。在优化条件下,该方法的检出限为0.005 ng/mL (n = 3),回收率为93.6% ~ 113.0%,准确度较高。此外,我们采用共聚焦荧光成像技术,使用R-CDs@SiO2偶联抗体作为荧光探针,可视化和定位心肌细胞(H9C2)内cTnI的分布。荧光免疫传感器成功地用于临床血清标本中cTnI水平的评估。结果与市售酶联免疫吸附测定(ELISA)试剂盒的结果一致。这表明所提出的方法为急性心肌梗死的临床诊断提供了一个强大的平台。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Applied Biochemistry and Biotechnology
Applied Biochemistry and Biotechnology 工程技术-生化与分子生物学
CiteScore
5.70
自引率
6.70%
发文量
460
审稿时长
5.3 months
期刊介绍: This journal is devoted to publishing the highest quality innovative papers in the fields of biochemistry and biotechnology. The typical focus of the journal is to report applications of novel scientific and technological breakthroughs, as well as technological subjects that are still in the proof-of-concept stage. Applied Biochemistry and Biotechnology provides a forum for case studies and practical concepts of biotechnology, utilization, including controls, statistical data analysis, problem descriptions unique to a particular application, and bioprocess economic analyses. The journal publishes reviews deemed of interest to readers, as well as book reviews, meeting and symposia notices, and news items relating to biotechnology in both the industrial and academic communities. In addition, Applied Biochemistry and Biotechnology often publishes lists of patents and publications of special interest to readers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书