Binary Phase Modulation FMCW Radar for High-Performance Multiperson Cardiac-Induced Thoracic Micro-Motion Sensing

IF 5.2 1区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Jingyun Lu;Jiayu Zhang;Yuchen Li;Changzhan Gu
{"title":"Binary Phase Modulation FMCW Radar for High-Performance Multiperson Cardiac-Induced Thoracic Micro-Motion Sensing","authors":"Jingyun Lu;Jiayu Zhang;Yuchen Li;Changzhan Gu","doi":"10.1109/TMTT.2026.3717968","DOIUrl":null,"url":null,"abstract":"This article focuses on the exploitation of binary phase modulation (BPM) radar architecture for multiperson fine-grained cardiac-induced thoracic micro-motion monitoring. The BPM scheme is developed based on a conventional frequency-modulated continuous-wave (FMCW) radar framework. By introducing a phase shifter at each transmit (TX) channel, all TX channels can operate simultaneously while preserving temporal resolution. Compared with conventional radar architectures, such as phased-array and time-division multiplexing (TDM) MIMO radar, the proposed scheme provides improved signal-to-noise ratio (<inline-formula> <tex-math>$SNR$ </tex-math></inline-formula>), making it suitable for noncontact biomedical sensing applications. A rigorous mathematical analysis of the BPM operating principle is presented in the context of vital sign extraction, with particular emphasis on the impact of practical imperfections, such as phase errors and amplitude mismatches, on displacement demodulation. A phase-based displacement reconstruction framework is proposed to recover thoracic motion and associated fine physiological information. Finally, a prototype BPM radar system is implemented, and experiments are conducted to validate its capability in target separation and high-fidelity reconstruction of micro-motion vital sign waveforms.","PeriodicalId":13272,"journal":{"name":"IEEE Transactions on Microwave Theory and Techniques","volume":"74 9","pages":"8368-8380"},"PeriodicalIF":5.2000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Microwave Theory and Techniques","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11644770/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/7 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

This article focuses on the exploitation of binary phase modulation (BPM) radar architecture for multiperson fine-grained cardiac-induced thoracic micro-motion monitoring. The BPM scheme is developed based on a conventional frequency-modulated continuous-wave (FMCW) radar framework. By introducing a phase shifter at each transmit (TX) channel, all TX channels can operate simultaneously while preserving temporal resolution. Compared with conventional radar architectures, such as phased-array and time-division multiplexing (TDM) MIMO radar, the proposed scheme provides improved signal-to-noise ratio ( $SNR$ ), making it suitable for noncontact biomedical sensing applications. A rigorous mathematical analysis of the BPM operating principle is presented in the context of vital sign extraction, with particular emphasis on the impact of practical imperfections, such as phase errors and amplitude mismatches, on displacement demodulation. A phase-based displacement reconstruction framework is proposed to recover thoracic motion and associated fine physiological information. Finally, a prototype BPM radar system is implemented, and experiments are conducted to validate its capability in target separation and high-fidelity reconstruction of micro-motion vital sign waveforms.
用于高性能多人心致胸微运动传感的二元相位调制FMCW雷达
本文重点研究了二元相位调制(BPM)雷达体系结构在多人细粒度心源性胸部微运动监测中的应用。BPM方案是在传统调频连续波(FMCW)雷达框架的基础上开发的。通过在每个发送(TX)通道引入移相器,所有TX通道可以同时工作,同时保持时间分辨率。与传统的雷达结构,如相控阵和时分复用(TDM) MIMO雷达相比,该方案提供了更高的信噪比(SNR),使其适用于非接触式生物医学传感应用。在生命体征提取的背景下,对BPM工作原理进行了严格的数学分析,特别强调了实际缺陷(如相位误差和幅度不匹配)对位移解调的影响。提出了一种基于相位的位移重建框架,用于恢复胸部运动和相关的精细生理信息。最后,实现了BPM雷达的原型系统,并通过实验验证了其目标分离能力和微运动生命体征波形的高保真重建能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Microwave Theory and Techniques
IEEE Transactions on Microwave Theory and Techniques 工程技术-工程:电子与电气
CiteScore
8.60
自引率
18.60%
发文量
486
审稿时长
6 months
期刊介绍: The IEEE Transactions on Microwave Theory and Techniques focuses on that part of engineering and theory associated with microwave/millimeter-wave components, devices, circuits, and systems involving the generation, modulation, demodulation, control, transmission, and detection of microwave signals. This includes scientific, technical, and industrial, activities. Microwave theory and techniques relates to electromagnetic waves usually in the frequency region between a few MHz and a THz; other spectral regions and wave types are included within the scope of the Society whenever basic microwave theory and techniques can yield useful results. Generally, this occurs in the theory of wave propagation in structures with dimensions comparable to a wavelength, and in the related techniques for analysis and design.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书