Effect of Garment Attachment Location on the Repeatability of IMU-Based Upper-Limb Motion Measurements

IF 2.4 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
IEEE Sensors Letters Pub Date : 2026-09-01 Epub Date: 2026-08-07 DOI:10.1109/LSENS.2026.3721914
Jeehyun Song;Robin Oberlé;Sumin Koo
{"title":"Effect of Garment Attachment Location on the Repeatability of IMU-Based Upper-Limb Motion Measurements","authors":"Jeehyun Song;Robin Oberlé;Sumin Koo","doi":"10.1109/LSENS.2026.3721914","DOIUrl":null,"url":null,"abstract":"Garment-integrated inertial measurement units (IMUs) are widely used for wearable motion sensing, but their measurement repeatability can be affected by relative motion between the garment and the body. This letter investigates how attachment location influences IMU measurement repeatability during repeated upper limb motions. Garment-mounted IMUs were compared with paired body-mounted reference sensors during repeated arm-elevation tasks. Sensors were placed at four upper limb locations—wrist, forearm, upper arm, and shoulder—on a regular-fitting sports jacket. Relative angular deviations were computed using a quaternion-based angular difference metric to compare repeatability across attachment locations. Experimental results from six participants, analyzed using a one-way repeated-measures analysis of variance with attachment location as the within-subject factor, revealed clear location-dependent differences in measurement behavior. The wrist exhibited the lowest trial-to-trial variability, followed by the forearm, whereas the shoulder exhibited the greatest variability despite a smaller mean angular deviation. A significant main effect of location was found for both mean angular deviation [F(3,15) = 7.761, <italic>p =</i> 0.002] and trial-to-trial variability [F(3,15) = 10.467, <italic>p =</i> 0.001]. These results suggest that attachment location is an important factor in the repeatability of garment-integrated IMU measurements under the present experimental conditions and provide preliminary guidance for sensor placement in wearable motion-sensing systems.","PeriodicalId":13014,"journal":{"name":"IEEE Sensors Letters","volume":"10 9","pages":"7004304-7004304"},"PeriodicalIF":2.4000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11644865/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Garment-integrated inertial measurement units (IMUs) are widely used for wearable motion sensing, but their measurement repeatability can be affected by relative motion between the garment and the body. This letter investigates how attachment location influences IMU measurement repeatability during repeated upper limb motions. Garment-mounted IMUs were compared with paired body-mounted reference sensors during repeated arm-elevation tasks. Sensors were placed at four upper limb locations—wrist, forearm, upper arm, and shoulder—on a regular-fitting sports jacket. Relative angular deviations were computed using a quaternion-based angular difference metric to compare repeatability across attachment locations. Experimental results from six participants, analyzed using a one-way repeated-measures analysis of variance with attachment location as the within-subject factor, revealed clear location-dependent differences in measurement behavior. The wrist exhibited the lowest trial-to-trial variability, followed by the forearm, whereas the shoulder exhibited the greatest variability despite a smaller mean angular deviation. A significant main effect of location was found for both mean angular deviation [F(3,15) = 7.761, p = 0.002] and trial-to-trial variability [F(3,15) = 10.467, p = 0.001]. These results suggest that attachment location is an important factor in the repeatability of garment-integrated IMU measurements under the present experimental conditions and provide preliminary guidance for sensor placement in wearable motion-sensing systems.
服装附着位置对基于imu的上肢运动测量重复性的影响
服装集成惯性测量单元(imu)广泛应用于可穿戴式运动传感,但其测量重复性会受到服装与身体之间相对运动的影响。这封信研究了在重复上肢运动中,附着位置如何影响IMU测量的重复性。在重复的手臂抬高任务中,将安装在衣服上的imu与成对安装在身体上的参考传感器进行比较。传感器被放置在上肢的四个位置——手腕、前臂、上臂和肩膀——在一件常规合身的运动夹克上。使用基于四元数的角差度量来计算相对角偏差,以比较不同附着位置的可重复性。对6名被试的实验结果进行了以依恋位置为主体内因素的单向重复测量方差分析,结果显示了明显的位置依赖性测量行为差异。手腕表现出最低的试验间可变性,其次是前臂,而肩膀表现出最大的可变性,尽管平均角度偏差较小。研究发现,位置对平均角偏差[F(3,15) = 7.761, p = 0.002]和试验间变异[F(3,15) = 10.467, p = 0.001]都有显著的主要影响。这些结果表明,在目前的实验条件下,附着位置是服装集成IMU测量可重复性的重要因素,并为可穿戴式运动传感系统中的传感器放置提供了初步指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Sensors Letters
IEEE Sensors Letters Engineering-Electrical and Electronic Engineering
CiteScore
3.50
自引率
7.10%
发文量
194
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书