Respiratory rate estimation by using realignment data from a 1-minute high-temporal-resolution MRI sequence: A feasibility study.

IF 1.2 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Leonie Zerweck, Uwe Klose, Ulrike Ernemann, Till-Karsten Hauser
{"title":"Respiratory rate estimation by using realignment data from a 1-minute high-temporal-resolution MRI sequence: A feasibility study.","authors":"Leonie Zerweck, Uwe Klose, Ulrike Ernemann, Till-Karsten Hauser","doi":"10.1177/02841851261484876","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundBreath-hold triggered functional magnetic resonance imaging (bh-fMRI) is a widely available, easily implementable and inexpensive method to quantify cerebrovascular reactivity. Estimation of patients' respiratory rate is relevant, as it might influence bh-fMRI data quality, but respiratory sensors integrated in the scanner table are not always available.PurposeTo propose an approach to estimate patients' respiratory rate using realignment data of a 1-min high-temporal-resolution cerebral MRI sequence.Material and MethodsIn a prospective study, 15 patients with Moyamoya angiopathy underwent a 1-min MRI sequence during routine clinical MRI. The respiratory rate was obtained by analyzing patients' head motion from image realignment data. To obtain robust results, the respiratory rate was calculated using a multi-method approach, incorporating power spectral density and fast Fourier transform and weighted data from multiparametric rigid body transformation. The respiratory rate detected from respiratory sensors integrated in the scanner table was used as reference. Bland-Altman analysis was performed and intra-class correlation coefficients (ICCs) were calculated to compare the respiratory rates.ResultsBland-Altman analysis revealed a mean bias of 0.5 breaths/min and limits of agreement (LoA) ranging from -5.3 to 4.4 breaths/min, with no outliers. The overall agreement between the respiratory rate calculated from realignment data and from scanner sensor data was excellent (ICC = 0.866, 95% confidence interval = 0.607-0.955; <i>P</i> < 0.001).ConclusionThe calculated mean bias and LoA appear to be clinically acceptable. Estimating respiratory rate from a 1-min high-temporal-resolution MRI sequence may be a feasible method when respiratory sensors integrated in the scanner are not available.</p>","PeriodicalId":7143,"journal":{"name":"Acta radiologica","volume":" ","pages":"2841851261484876"},"PeriodicalIF":1.2000,"publicationDate":"2026-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02841851261484876","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

BackgroundBreath-hold triggered functional magnetic resonance imaging (bh-fMRI) is a widely available, easily implementable and inexpensive method to quantify cerebrovascular reactivity. Estimation of patients' respiratory rate is relevant, as it might influence bh-fMRI data quality, but respiratory sensors integrated in the scanner table are not always available.PurposeTo propose an approach to estimate patients' respiratory rate using realignment data of a 1-min high-temporal-resolution cerebral MRI sequence.Material and MethodsIn a prospective study, 15 patients with Moyamoya angiopathy underwent a 1-min MRI sequence during routine clinical MRI. The respiratory rate was obtained by analyzing patients' head motion from image realignment data. To obtain robust results, the respiratory rate was calculated using a multi-method approach, incorporating power spectral density and fast Fourier transform and weighted data from multiparametric rigid body transformation. The respiratory rate detected from respiratory sensors integrated in the scanner table was used as reference. Bland-Altman analysis was performed and intra-class correlation coefficients (ICCs) were calculated to compare the respiratory rates.ResultsBland-Altman analysis revealed a mean bias of 0.5 breaths/min and limits of agreement (LoA) ranging from -5.3 to 4.4 breaths/min, with no outliers. The overall agreement between the respiratory rate calculated from realignment data and from scanner sensor data was excellent (ICC = 0.866, 95% confidence interval = 0.607-0.955; P < 0.001).ConclusionThe calculated mean bias and LoA appear to be clinically acceptable. Estimating respiratory rate from a 1-min high-temporal-resolution MRI sequence may be a feasible method when respiratory sensors integrated in the scanner are not available.

利用1分钟高时间分辨率MRI序列的重新排列数据估计呼吸速率:可行性研究。
屏气触发的功能磁共振成像(bh-fMRI)是一种广泛可用、易于实施且廉价的量化脑血管反应性的方法。患者呼吸频率的估计是相关的,因为它可能影响bh-fMRI数据质量,但在扫描表中集成的呼吸传感器并不总是可用的。目的提出一种利用1分钟高时间分辨率脑MRI序列重新排列数据估计患者呼吸频率的方法。材料和方法在一项前瞻性研究中,15例烟雾病患者在常规临床MRI期间接受了1分钟的MRI序列检查。通过对患者头部运动的图像调整数据进行分析,得到呼吸频率。为了获得稳健的结果,采用多方法计算呼吸频率,结合功率谱密度和快速傅立叶变换以及多参数刚体变换的加权数据。以扫描台上集成的呼吸传感器检测到的呼吸频率为参考。进行Bland-Altman分析并计算类内相关系数(ICCs)来比较呼吸频率。结果bland - altman分析显示,平均偏差为0.5呼吸/min,一致限(LoA)范围为-5.3至4.4呼吸/min,无异常值。根据重新排列数据计算的呼吸率与扫描仪传感器数据之间的总体一致性非常好(ICC = 0.866, 95%可信区间= 0.607-0.955
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta radiologica
Acta radiologica 医学-核医学
CiteScore
2.70
自引率
0.00%
发文量
170
审稿时长
3-8 weeks
期刊介绍: Acta Radiologica publishes articles on all aspects of radiology, from clinical radiology to experimental work. It is known for articles based on experimental work and contrast media research, giving priority to scientific original papers. The distinguished international editorial board also invite review articles, short communications and technical and instrumental notes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书