{"title":"A Bilayer Liquid–Metal Interdigitated Capacitive Sensor for Omnidirectional Strain Decoupling in Wearable Motion Monitoring","authors":"Fan Lei, Yandong Yang, Jiayi Yang, Zheng Zhang","doi":"10.1007/s11664-026-13103-6","DOIUrl":null,"url":null,"abstract":"<div><p>Soft and stretchable strain sensors are important for human–machine interfaces, soft robotics, and electronic skins. However, most existing sensors cannot simultaneously resolve strain magnitude and direction and are easily affected by normal pressure under multidirectional deformation. To solve this problem, we present a bilayer liquid–metal interdigitated capacitive omnidirectional flexible strain sensor. The device employs liquid–metal interdigitated electrodes encapsulated in Ecoflex and is fabricated as a five-layer sandwich structure via a low-cost mask-assisted laser patterning process. By integrating two capacitive sensing units, <i>C</i><sub>1</sub> (lower sensing layer) and <i>C</i><sub>2</sub> (upper sensing layer), with distinct orientations in a 30° cross-stacked architecture, the device can detect in-plane strain with different directional responses. Single-layer interdigitated electrodes show different capacitive responses when stretched parallel or perpendicular to the electrode direction, whereas the bilayer structure generates distinguishable dual-channel outputs over tensile directions from 0° to 180°. Simulations and experiments confirm a linear, repeatable, and direction-dependent response under multidirectional stretching. Leave-one-angle-out cross-validation yielded a mean absolute angular error of 3.12°, an angular root-mean-square error of 3.70°, and a maximum absolute angular error of 6.05°. Under normal loads of 10–17.5 N, the capacitance signals of both channels remain nearly unchanged, indicating low sensitivity to normal pressure. On-body tests further showed that the sensor records stable and reproducible direction-dependent strain signals during periodic wrist, knee, and waist motions. This work provides a design strategy for flexible capacitive strain sensors in wearable direction-resolved strain monitoring, health sensing, and electronic skin.</p></div>","PeriodicalId":626,"journal":{"name":"Journal of Electronic Materials","volume":"55 10","pages":"8546 - 8560"},"PeriodicalIF":2.8000,"publicationDate":"2026-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronic Materials","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s11664-026-13103-6","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Soft and stretchable strain sensors are important for human–machine interfaces, soft robotics, and electronic skins. However, most existing sensors cannot simultaneously resolve strain magnitude and direction and are easily affected by normal pressure under multidirectional deformation. To solve this problem, we present a bilayer liquid–metal interdigitated capacitive omnidirectional flexible strain sensor. The device employs liquid–metal interdigitated electrodes encapsulated in Ecoflex and is fabricated as a five-layer sandwich structure via a low-cost mask-assisted laser patterning process. By integrating two capacitive sensing units, C1 (lower sensing layer) and C2 (upper sensing layer), with distinct orientations in a 30° cross-stacked architecture, the device can detect in-plane strain with different directional responses. Single-layer interdigitated electrodes show different capacitive responses when stretched parallel or perpendicular to the electrode direction, whereas the bilayer structure generates distinguishable dual-channel outputs over tensile directions from 0° to 180°. Simulations and experiments confirm a linear, repeatable, and direction-dependent response under multidirectional stretching. Leave-one-angle-out cross-validation yielded a mean absolute angular error of 3.12°, an angular root-mean-square error of 3.70°, and a maximum absolute angular error of 6.05°. Under normal loads of 10–17.5 N, the capacitance signals of both channels remain nearly unchanged, indicating low sensitivity to normal pressure. On-body tests further showed that the sensor records stable and reproducible direction-dependent strain signals during periodic wrist, knee, and waist motions. This work provides a design strategy for flexible capacitive strain sensors in wearable direction-resolved strain monitoring, health sensing, and electronic skin.
期刊介绍:
The Journal of Electronic Materials (JEM) reports monthly on the science and technology of electronic materials, while examining new applications for semiconductors, magnetic alloys, dielectrics, nanoscale materials, and photonic materials. The journal welcomes articles on methods for preparing and evaluating the chemical, physical, electronic, and optical properties of these materials. Specific areas of interest are materials for state-of-the-art transistors, nanotechnology, electronic packaging, detectors, emitters, metallization, superconductivity, and energy applications.
Review papers on current topics enable individuals in the field of electronics to keep abreast of activities in areas peripheral to their own. JEM also selects papers from conferences such as the Electronic Materials Conference, the U.S. Workshop on the Physics and Chemistry of II-VI Materials, and the International Conference on Thermoelectrics. It benefits both specialists and non-specialists in the electronic materials field.
A journal of The Minerals, Metals & Materials Society.