Fully automated analysis of cardiotoxicity surveillance echocardiograms: a direct test-retest precision comparison with experts.

European heart journal. Imaging methods and practice Pub Date : 2026-08-21 eCollection Date: 2026-08-01 DOI:10.1093/ehjimp/qyag142
Benjamin Dowsing, Katia Menacho, Verónica Culotta, Benjamin Meredith, Beth Unsworth, Adam Ioannou, Anish Bhuva, Rhodri Davies, Ana Ferreira, Arjun Ghosh, Mark Westwood, Leon Menezes, Marianna Fontana, Guy Lloyd, Matthew Shun-Shin, James C Moon, Charlotte H Manisty
{"title":"Fully automated analysis of cardiotoxicity surveillance echocardiograms: a direct test-retest precision comparison with experts.","authors":"Benjamin Dowsing, Katia Menacho, Verónica Culotta, Benjamin Meredith, Beth Unsworth, Adam Ioannou, Anish Bhuva, Rhodri Davies, Ana Ferreira, Arjun Ghosh, Mark Westwood, Leon Menezes, Marianna Fontana, Guy Lloyd, Matthew Shun-Shin, James C Moon, Charlotte H Manisty","doi":"10.1093/ehjimp/qyag142","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Serial imaging demands precision-particularly for cardiotoxicity screening where small changes gatekeep major decisions. Automated measurement using artificial intelligence (AI)-based techniques should reduce variability and increase confidence for detection of true change. We directly compared the precision of fully automated AI vs. expert manual analysis of left ventricular function by echocardiography.</p><p><strong>Methods and results: </strong>Consecutive cancer patients referred for cardiotoxicity monitoring underwent same-day repeat 2D echocardiography [<i>n</i> = 60, 83% female, mean left ventricular ejection fraction (LVEF) 57 ± 7%], with 3D acquisition where feasible (<i>n</i> = 45). All 2D images underwent blinded analysis by a fully automated analysis software and four experts. Quantitative 2D LVEF measurement was feasible in 96% scans by both methods. Mean absolute difference (MAD) between repeat scans was significantly lower for AI than experts for both 2D LVEF {3.6% [confidence interval (CI) 2.8-4.4] vs. 6.6% [CI 5.3-7.9], <i>P</i> = 0.011} and global longitudinal strain [1.5% (CI 1.1-1.9) vs. 2.5% (CI 2.0-3.0), <i>P</i> = 0.006]. In participants with 3DE datasets, 3D LVEF MAD was lower than manual 2D LVEF [3.6% (CI 2.8-4.6) vs. 6.4% (CI 5.0-8.0), <i>P</i> = 0.006] but comparable to AI-derived 2D LVEF [3.5% (CI 2.9-4.2), <i>P</i> = 0.4]. In a subset (<i>n</i> = 48) also with same-day cardiovascular magnetic resonance (CMR) studies, AI 2DE analysis demonstrated stronger agreement with CMR than expert 2DE analysis [LVEF MAD 5.0% (CI 4.1-5.9) vs. 7.8% (CI 6.6-9.0) <i>P</i> = 0.006].</p><p><strong>Conclusion: </strong>In cancer patients at risk of cardiotoxicity, the precision of 2D echocardiographic AI analysis exceeds that of experts, matching that of 3D LVEF assessment.</p><p><strong>Trial registration: </strong>NCT06817044.</p><p><strong>Lay summary: </strong>Some cancer treatments may weaken the heart. As such, at-risk patients have repeat heart scans (echocardiograms) over the course of their cancer treatment. Doctors monitor these scans over time and watch closely for any change; even a small decline in heart function can trigger a major decision, such as pausing life-saving cancer therapy. It is therefore vital that these measurements are as consistent or 'precise' as possible.The problem is that measurements taken by hand can vary widely, and 'precision' may be low, even when performed by skilled experts. This makes it hard to know whether a change in heart function across follow-up scans is real or not and whether any action is therefore needed. We tested whether artificial intelligence (AI) software could measure heart function more precisely than experts.Sixty cancer patients each had two echocardiographic heart scans in close succession on the same day. This approach purposefully reduces the impact of other factors (such as differences in the person or equipment performing the heart scan) that might otherwise mean results differ. We then compared how closely the repeat measurements of heart function matched when performed by AI vs. four echocardiography experts. The AI was more precise, giving closer results between the two scans, whilst the experts' results varied more.In short, AI can measure heart function more precisely than experts in patients with cancer. This could give doctors greater confidence that any change seen on a scan is genuine, helping them make safer, better-informed decisions.</p>","PeriodicalId":94317,"journal":{"name":"European heart journal. Imaging methods and practice","volume":"4 3","pages":"qyag142"},"PeriodicalIF":0.0000,"publicationDate":"2026-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13547863/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European heart journal. Imaging methods and practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjimp/qyag142","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Serial imaging demands precision-particularly for cardiotoxicity screening where small changes gatekeep major decisions. Automated measurement using artificial intelligence (AI)-based techniques should reduce variability and increase confidence for detection of true change. We directly compared the precision of fully automated AI vs. expert manual analysis of left ventricular function by echocardiography.

Methods and results: Consecutive cancer patients referred for cardiotoxicity monitoring underwent same-day repeat 2D echocardiography [n = 60, 83% female, mean left ventricular ejection fraction (LVEF) 57 ± 7%], with 3D acquisition where feasible (n = 45). All 2D images underwent blinded analysis by a fully automated analysis software and four experts. Quantitative 2D LVEF measurement was feasible in 96% scans by both methods. Mean absolute difference (MAD) between repeat scans was significantly lower for AI than experts for both 2D LVEF {3.6% [confidence interval (CI) 2.8-4.4] vs. 6.6% [CI 5.3-7.9], P = 0.011} and global longitudinal strain [1.5% (CI 1.1-1.9) vs. 2.5% (CI 2.0-3.0), P = 0.006]. In participants with 3DE datasets, 3D LVEF MAD was lower than manual 2D LVEF [3.6% (CI 2.8-4.6) vs. 6.4% (CI 5.0-8.0), P = 0.006] but comparable to AI-derived 2D LVEF [3.5% (CI 2.9-4.2), P = 0.4]. In a subset (n = 48) also with same-day cardiovascular magnetic resonance (CMR) studies, AI 2DE analysis demonstrated stronger agreement with CMR than expert 2DE analysis [LVEF MAD 5.0% (CI 4.1-5.9) vs. 7.8% (CI 6.6-9.0) P = 0.006].

Conclusion: In cancer patients at risk of cardiotoxicity, the precision of 2D echocardiographic AI analysis exceeds that of experts, matching that of 3D LVEF assessment.

Trial registration: NCT06817044.

Lay summary: Some cancer treatments may weaken the heart. As such, at-risk patients have repeat heart scans (echocardiograms) over the course of their cancer treatment. Doctors monitor these scans over time and watch closely for any change; even a small decline in heart function can trigger a major decision, such as pausing life-saving cancer therapy. It is therefore vital that these measurements are as consistent or 'precise' as possible.The problem is that measurements taken by hand can vary widely, and 'precision' may be low, even when performed by skilled experts. This makes it hard to know whether a change in heart function across follow-up scans is real or not and whether any action is therefore needed. We tested whether artificial intelligence (AI) software could measure heart function more precisely than experts.Sixty cancer patients each had two echocardiographic heart scans in close succession on the same day. This approach purposefully reduces the impact of other factors (such as differences in the person or equipment performing the heart scan) that might otherwise mean results differ. We then compared how closely the repeat measurements of heart function matched when performed by AI vs. four echocardiography experts. The AI was more precise, giving closer results between the two scans, whilst the experts' results varied more.In short, AI can measure heart function more precisely than experts in patients with cancer. This could give doctors greater confidence that any change seen on a scan is genuine, helping them make safer, better-informed decisions.

心脏毒性监测超声心动图的全自动分析:与专家的直接测试-重测精度比较。
目的:连续成像要求精确-特别是在心脏毒性筛查中,微小的变化可能会影响重大的决定。使用基于人工智能(AI)的技术的自动化测量应该减少可变性,并增加检测真实变化的信心。我们直接比较了全自动人工智能与专家人工超声心动图左心室功能分析的精度。方法和结果:连续接受心脏毒性监测的癌症患者接受当日重复二维超声心动图检查[n = 60, 83%女性,平均左室射血分数(LVEF) 57±7%],可行时进行三维采集(n = 45)。所有二维图像均由全自动分析软件和四名专家进行盲法分析。两种方法的二维LVEF定量测量在96%的扫描中是可行的。人工智能重复扫描的平均绝对差(MAD)在2D LVEF[3.6%[置信区间(CI) 2.8-4.4]对6.6% [CI 5.3-7.9], P = 0.011]和整体纵向应变[1.5% (CI 1.1-1.9)对2.5% (CI 2.0-3.0), P = 0.006]上均显著低于专家。在3DE数据集的参与者中,3D LVEF的MAD低于手动2D LVEF [3.6% (CI 2.8-4.6) vs. 6.4% (CI 5.0-8.0), P = 0.006],但与ai衍生的2D LVEF [3.5% (CI 2.9-4.2), P = 0.4]相当。在同日进行心血管磁共振(CMR)研究的一个子集(n = 48)中,AI 2DE分析与CMR的一致性比专家2DE分析更强[LVEF MAD 5.0% (CI 4.1-5.9)比7.8% (CI 6.6-9.0) P = 0.006]。结论:在有心脏毒性风险的癌症患者中,二维超声心动图AI分析的精度超过专家,与三维LVEF评估的精度相当。试验注册:NCT06817044。概要:一些癌症治疗可能会削弱心脏。因此,在癌症治疗过程中,高危患者需要重复心脏扫描(超声心动图)。医生会长期监测这些扫描,密切关注任何变化;即使是心脏功能的轻微下降也会引发重大决定,比如暂停挽救生命的癌症治疗。因此,这些测量尽可能保持一致或“精确”是至关重要的。问题是,手工测量的结果差异很大,而且“精度”可能很低,即使是由熟练的专家进行测量。这使得很难知道在后续扫描中心脏功能的变化是否真实,以及是否因此需要采取任何行动。我们测试了人工智能(AI)软件是否能比专家更精确地测量心脏功能。60名癌症患者在同一天连续两次接受心脏超声扫描。这种方法有目的地减少了其他因素的影响(例如执行心脏扫描的人或设备的差异),否则可能导致结果不同。然后,我们比较了人工智能与四位超声心动图专家进行的心脏功能重复测量的匹配程度。人工智能更精确,两次扫描的结果更接近,而专家的结果差异更大。简而言之,人工智能可以比癌症患者的专家更精确地测量心脏功能。这可以让医生更有信心,相信扫描中看到的任何变化都是真实的,从而帮助他们做出更安全、更明智的决定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书