Functional Assessment of Platelet-Derived Phospholipid Activity in Pooled Normal Plasmas by Low-Phospholipid Thrombin Generation Assay and Its Impact on Lupus Anticoagulant Mixing Tests.

Osamu Kumano, Masato Matsuda, Mino Sakata, Osamu Maruyama
{"title":"Functional Assessment of Platelet-Derived Phospholipid Activity in Pooled Normal Plasmas by Low-Phospholipid Thrombin Generation Assay and Its Impact on Lupus Anticoagulant Mixing Tests.","authors":"Osamu Kumano, Masato Matsuda, Mino Sakata, Osamu Maruyama","doi":"10.1111/ijlh.70247","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pooled normal plasma (PNP) used for lupus anticoagulant (LA) mixing tests may carry platelet-derived phospholipid (PL) activity introduced during freezing/lyophilization, potentially attenuating LA-mediated prolongation of clotting times.</p><p><strong>Objectives: </strong>To determine whether thrombin generation assay (TGA) under low-PL conditions functionally captures endogenous, platelet-derived PL activity in commercial PNP and relates to LA mixing outcomes.</p><p><strong>Methods: </strong>Four commercial PNPs (CRYOcheck PNP, Coagtrol N, SHP, Ci-Trol 1) were tested by TGA at PL 4, 1, 0.1, and 0 μM with 1 pM tissue factor and 1.6 μM corn trypsin inhibitor. LA weak-positive and LA positive controls were mixed 1:1 with each PNP and assessed by five APTT reagents to compute the index of circulating anticoagulant (ICA). Platelet factor 4 (PF4) levels were measured by ELISA.</p><p><strong>Results: </strong>SHP and Ci-Trol 1 showed consistently higher TGA peak heights than CRYOcheck PNP and Coagtrol N across all PL concentrations; thrombin generation persisted at 0 μM PL, consistent with activity in the absence of added PL. The other TGA parameters exhibited the same trend. Mean ICA values were inversely correlated with TGA peak height at 4 and 1 μM PL (r ≤ -0.985), with direction preserved at 0.1 and 0 μM. PF4 levels were markedly higher in SHP and Ci-Trol 1 and paralleled higher TGA peak height and lower ICA.</p><p><strong>Conclusions: </strong>Endogenous, platelet-derived PL activity in commercial PNP is a key determinant of the LA mixing test performance. TGA under low-PL conditions, complemented by PF4 measurement, offers a practical approach to qualify PNP lots and reduce the under recognition of LA.</p>","PeriodicalId":94050,"journal":{"name":"International journal of laboratory hematology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of laboratory hematology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/ijlh.70247","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Pooled normal plasma (PNP) used for lupus anticoagulant (LA) mixing tests may carry platelet-derived phospholipid (PL) activity introduced during freezing/lyophilization, potentially attenuating LA-mediated prolongation of clotting times.

Objectives: To determine whether thrombin generation assay (TGA) under low-PL conditions functionally captures endogenous, platelet-derived PL activity in commercial PNP and relates to LA mixing outcomes.

Methods: Four commercial PNPs (CRYOcheck PNP, Coagtrol N, SHP, Ci-Trol 1) were tested by TGA at PL 4, 1, 0.1, and 0 μM with 1 pM tissue factor and 1.6 μM corn trypsin inhibitor. LA weak-positive and LA positive controls were mixed 1:1 with each PNP and assessed by five APTT reagents to compute the index of circulating anticoagulant (ICA). Platelet factor 4 (PF4) levels were measured by ELISA.

Results: SHP and Ci-Trol 1 showed consistently higher TGA peak heights than CRYOcheck PNP and Coagtrol N across all PL concentrations; thrombin generation persisted at 0 μM PL, consistent with activity in the absence of added PL. The other TGA parameters exhibited the same trend. Mean ICA values were inversely correlated with TGA peak height at 4 and 1 μM PL (r ≤ -0.985), with direction preserved at 0.1 and 0 μM. PF4 levels were markedly higher in SHP and Ci-Trol 1 and paralleled higher TGA peak height and lower ICA.

Conclusions: Endogenous, platelet-derived PL activity in commercial PNP is a key determinant of the LA mixing test performance. TGA under low-PL conditions, complemented by PF4 measurement, offers a practical approach to qualify PNP lots and reduce the under recognition of LA.

用低磷脂凝血酶生成法评价正常血浆血小板源性磷脂活性及其对狼疮抗凝血混合试验的影响
背景:用于狼疮抗凝剂(LA)混合试验的混合正常血浆(PNP)可能携带在冷冻/冻干过程中引入的血小板衍生磷脂(PL)活性,可能减弱LA介导的凝血时间延长。目的:确定低PL条件下凝血酶生成试验(TGA)是否能捕获商业PNP中内源性血小板来源的PL活性,并与LA混合结果相关。方法:4种商业PNP (CRYOcheck PNP、trol N、SHP、Ci-Trol 1)在PL 4、1、0.1和0 μM下,用1 pM组织因子和1.6 μM玉米胰蛋白酶抑制剂进行TGA检测。将LA弱阳性和LA阳性对照与各PNP按1:1混合,用5种APTT试剂进行评估,计算循环抗凝血指数(ICA)。ELISA法检测血小板因子4 (PF4)水平。结果:在所有PL浓度下,SHP和Ci-Trol 1的TGA峰高度均高于CRYOcheck PNP和ciotrol N;在0 μM PL条件下,凝血酶的生成仍然存在,与不添加PL时的活性一致。其他TGA参数也表现出相同的趋势。在4和1 μM PL处,ICA平均值与TGA峰高呈负相关(r≤-0.985),在0.1和0 μM处方向保持不变。SHP和ci - tro1中PF4水平明显升高,并伴有较高的TGA峰高和较低的ICA。结论:商业PNP中内源性血小板来源的PL活性是LA混合测试性能的关键决定因素。低pl条件下的TGA,辅以PF4测量,提供了一种实用的方法来鉴定PNP批次并减少LA的识别不足。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书