{"title":"Corneal Thickness, Curvature and Topographic Indices: Implications for Keratoconus Screening in a South African University Clinic Population.","authors":"Pheagane Motsime William Nkoana, Neo Makgatho, Rethabile Ramatsobane Lekgau, Mufhatutshedzwa M Randima, Munei Masiagwala, Moloantoa Morena, Lebogang Shaun Ntsobe, Phuti Germina Matlhadisha","doi":"10.2147/OPTO.S622334","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Keratoconus (KC) is a progressive corneal ectatic disorder characterised by thinning and irregular steepening, which may lead to visual impairment if not detected early. Most diagnostic thresholds are derived from non-African populations, limiting their relevance in local settings.</p><p><strong>Aim: </strong>To profile corneal thickness, curvature, eccentricity and topographic indices, and assess their implications for keratoconus screening in a South African university clinic population.</p><p><strong>Methods: </strong>A quantitative cross-sectional study was conducted using clinical data from patients attending a university optometry clinic. Mean central corneal thickness (CCT), radius of curvature (<i>r</i>), eccentricity (<i>e</i>) and KC related indices of 300 clinic patients were measured using Oculus Pentacam. Descriptive and inferential statistics were used to analyse the data.</p><p><strong>Results: </strong>Corneal parameters were generally within normal ranges. The mean CCT was 504.79 ± 33.12 µm. The mean <i>r</i> was 7.83 ± 0.28 mm, indicating relatively flatter corneas compared to some international populations. Mean <i>e-</i>value was 0.47 ± 0.13, suggesting prolate corneal profiles. Keratoconus related indices were largely within normal limits, although they appeared more conservative than corneal thickness in identifying suspected ectasia. Weak to moderate correlations were observed between variables.</p><p><strong>Conclusion: </strong>Corneal characteristics were within normal limits but showed subtle population specific variation. A multi-parameter approach integrating thickness, curvature and indices is recommended to improve KC screening and to strengthen region-specific diagnostic thresholds.</p>","PeriodicalId":43701,"journal":{"name":"Clinical Optometry","volume":"18 ","pages":"622334"},"PeriodicalIF":2.4000,"publicationDate":"2026-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13549292/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Optometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTO.S622334","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Keratoconus (KC) is a progressive corneal ectatic disorder characterised by thinning and irregular steepening, which may lead to visual impairment if not detected early. Most diagnostic thresholds are derived from non-African populations, limiting their relevance in local settings.
Aim: To profile corneal thickness, curvature, eccentricity and topographic indices, and assess their implications for keratoconus screening in a South African university clinic population.
Methods: A quantitative cross-sectional study was conducted using clinical data from patients attending a university optometry clinic. Mean central corneal thickness (CCT), radius of curvature (r), eccentricity (e) and KC related indices of 300 clinic patients were measured using Oculus Pentacam. Descriptive and inferential statistics were used to analyse the data.
Results: Corneal parameters were generally within normal ranges. The mean CCT was 504.79 ± 33.12 µm. The mean r was 7.83 ± 0.28 mm, indicating relatively flatter corneas compared to some international populations. Mean e-value was 0.47 ± 0.13, suggesting prolate corneal profiles. Keratoconus related indices were largely within normal limits, although they appeared more conservative than corneal thickness in identifying suspected ectasia. Weak to moderate correlations were observed between variables.
Conclusion: Corneal characteristics were within normal limits but showed subtle population specific variation. A multi-parameter approach integrating thickness, curvature and indices is recommended to improve KC screening and to strengthen region-specific diagnostic thresholds.
期刊介绍:
Clinical Optometry is an international, peer-reviewed, open access journal focusing on clinical optometry. All aspects of patient care are addressed within the journal as well as the practice of optometry including economic and business analyses. Basic and clinical research papers are published that cover all aspects of optics, refraction and its application to the theory and practice of optometry. Specific topics covered in the journal include: Theoretical and applied optics, Delivery of patient care in optometry practice, Refraction and correction of errors, Screening and preventative aspects of eye disease, Extended clinical roles for optometrists including shared care and provision of medications, Teaching and training optometrists, International aspects of optometry, Business practice, Patient adherence, quality of life, satisfaction, Health economic evaluations.