Comparative Evaluation of Two Modified Glass Ionomer Cements with Conventional Glass Ionomer Cement for Fracture Toughness using 3-point Bending Test.

Revista Cientifica Odontologica Pub Date : 2026-07-10 eCollection Date: 2026-07-01 DOI:10.21142/2523-2754-1403-2026-297
Trisha Patel, Farhin Katge, Devendra Patil, Vamsi Krishna, Parin Bhanushali
{"title":"Comparative Evaluation of Two Modified Glass Ionomer Cements with Conventional Glass Ionomer Cement for Fracture Toughness using 3-point Bending Test.","authors":"Trisha Patel, Farhin Katge, Devendra Patil, Vamsi Krishna, Parin Bhanushali","doi":"10.21142/2523-2754-1403-2026-297","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The purpose of this study was to evaluate and compare the fracture toughness of Advanced glass hybrid Glass Ionomer Cement (GIC), Zirconium reinforced GIC and conventional GIC using 3-point bending test.</p><p><strong>Materials and methods: </strong>Three groups were formed in the present study, Group 1 (Hybrid GIC), Group 2 (Zirconomer Improved), Group 3 (Conventional GIC) which were tested at 24 hours and 7 days time interval according to their storage time in artificial saliva. Samples of each material were prepared with the help of customized mould of dimensions 25 mm*5 mm*2.5 mm and stored for 24 hours and 7 days in artificial saliva. The fracture toughness testing was done in a 3-point bend apparatus using Universal Testing Machine with a crosshead speed of 1 mm/min until failure. The mean fracture toughness values were compared using two-way ANOVA followed by post hoc (Bonferreni). The values at 24 hours and 7 days were compared using paired t-test.</p><p><strong>Results: </strong>At 24 hours and 7 days, Advanced Glass Hybrid GIC showed the highest fracture toughness values, while the lowest values were observed with conventional GIC. A statistically significant difference was seen between Advanced Glass Hybrid GIC and conventional GIC at 24 hours. Zirconium reinforced GIC showed intermediate values. In intra-group comparison, an increase in values was seen with all 3 materials at 7 days, however the difference was statistically insignificant.</p><p><strong>Conclusions: </strong>Advanced Glass Hybrid and Zirconium reinforced GIC showed better fracture toughness than the Conventional GIC. Fracture toughness of GICs was influenced by time.</p>","PeriodicalId":33326,"journal":{"name":"Revista Cientifica Odontologica","volume":"14 3","pages":"e297"},"PeriodicalIF":0.0000,"publicationDate":"2026-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13549670/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Cientifica Odontologica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21142/2523-2754-1403-2026-297","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The purpose of this study was to evaluate and compare the fracture toughness of Advanced glass hybrid Glass Ionomer Cement (GIC), Zirconium reinforced GIC and conventional GIC using 3-point bending test.

Materials and methods: Three groups were formed in the present study, Group 1 (Hybrid GIC), Group 2 (Zirconomer Improved), Group 3 (Conventional GIC) which were tested at 24 hours and 7 days time interval according to their storage time in artificial saliva. Samples of each material were prepared with the help of customized mould of dimensions 25 mm*5 mm*2.5 mm and stored for 24 hours and 7 days in artificial saliva. The fracture toughness testing was done in a 3-point bend apparatus using Universal Testing Machine with a crosshead speed of 1 mm/min until failure. The mean fracture toughness values were compared using two-way ANOVA followed by post hoc (Bonferreni). The values at 24 hours and 7 days were compared using paired t-test.

Results: At 24 hours and 7 days, Advanced Glass Hybrid GIC showed the highest fracture toughness values, while the lowest values were observed with conventional GIC. A statistically significant difference was seen between Advanced Glass Hybrid GIC and conventional GIC at 24 hours. Zirconium reinforced GIC showed intermediate values. In intra-group comparison, an increase in values was seen with all 3 materials at 7 days, however the difference was statistically insignificant.

Conclusions: Advanced Glass Hybrid and Zirconium reinforced GIC showed better fracture toughness than the Conventional GIC. Fracture toughness of GICs was influenced by time.

用三点弯曲试验比较评价两种改性玻璃离聚体水泥与常规玻璃离聚体水泥的断裂韧性。
目的:采用三点弯曲试验对高级玻璃杂化玻璃离子水泥(GIC)、锆增强GIC和常规GIC的断裂韧性进行评价和比较。材料与方法:本研究分为三组,1组(杂交GIC), 2组(改良锆合金),3组(常规GIC),根据其在人工唾液中的储存时间间隔24小时和7天进行检测。每种材料的样品通过尺寸为25mm * 5mm *2.5 mm的定制模具制备,在人工唾液中保存24小时和7天。断裂韧性测试在三点弯曲装置上进行,使用万能试验机,十字速度为1mm /min,直至失效。使用双向方差分析和事后分析(Bonferreni)对平均断裂韧性值进行比较。采用配对t检验比较24小时和7天的数值。结果:在24小时和7天时,Advanced Glass Hybrid GIC的断裂韧性值最高,而常规GIC的断裂韧性值最低。先进玻璃混合GIC与常规GIC在24小时的统计学差异显著。锆增强GIC表现为中间值。在组内比较中,3种材料在第7天的数值均有所增加,但差异无统计学意义。结论:先进玻璃杂化锆增强GIC具有较好的断裂韧性。GICs的断裂韧性受时间的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
43
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书