Dustiness of graphene and graphite.

IF 1.4 4区 医学 Q4 ENVIRONMENTAL SCIENCES
Douglas E Evans, M Christina Kander, Chen Wang, Peter B Shaw, Seth McCormick, Kabir Rishi, Terrence S Kuca, Derek E Stinson, Gregory J Deye, Matthew M Dahm
{"title":"Dustiness of graphene and graphite.","authors":"Douglas E Evans, M Christina Kander, Chen Wang, Peter B Shaw, Seth McCormick, Kabir Rishi, Terrence S Kuca, Derek E Stinson, Gregory J Deye, Matthew M Dahm","doi":"10.1080/15459624.2026.2692355","DOIUrl":null,"url":null,"abstract":"<p><p>Graphene is among the most utilized nanoscale materials in the United States. It is a single-layer carbonaceous nanoscale material with a hexagonal structure. Subtractive synthesis from graphite is common in high-volume manufacturing, with graphene and graphite often present within the same workplace. There is little worker exposure data available to inform risk assessments, particularly for graphene. Dustiness determinations using EN15051-2 <i>Workplace Exposure-Measurement of the Dustiness of Bulk Materials. Part 2: Rotating Drum Method</i> were conducted for two graphene nanoplatelets, two graphene oxides, one few-layered graphene, one furnace carbon black, three natural and five synthetic graphites, and two coals. All 16 test materials were composed mostly of carbon. Dustiness determinations were compared to established thresholds for the inhalable, thoracic, and respirable particle size fractions. Measurements of specific surface area, moisture content, and unconsolidated bulk density were further obtained. Particles were imaged through scanning electron microscopy. The EN15051-2 test is a gentle gravity-induced procedure where the test material falls a limited distance. Dustiness determinations resulted in 2.2% or less of the test material collected in the inhalable size fraction, 0.89% or less in the thoracic, and 0.37% or less in the respirable subfraction. The thoracic fraction constituted ∼31% of the inhalable fraction overall. The masses of four of five graphenes were below the gravimetric limit of detection of 0.57 µg in the respirable size fraction. Contributing factors were the gentle nature of the test and low unconsolidated bulk densities (5.9 to 174 kg/m<sup>3</sup>) for the nanoscale materials, resulting in 0.21 to 6.1 g loaded masses. Modest enhancements to the testing protocol could potentially improve quantification for low-density materials. All test materials and quantifiable size fractions were classified as moderate or high dustiness on a mg/kg basis. The carbonaceous materials in this study have a moderate to high propensity of becoming airborne when subjected to a gentle gravity-induced stimulus. Without adequate controls to prevent dust emissions, handling could result in inhalation, dermal, and mucous membrane exposures as well as present slip, electrical, fire, and dust explosion hazards.</p>","PeriodicalId":16599,"journal":{"name":"Journal of Occupational and Environmental Hygiene","volume":" ","pages":"1-16"},"PeriodicalIF":1.4000,"publicationDate":"2026-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13662783/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Occupational and Environmental Hygiene","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1080/15459624.2026.2692355","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Graphene is among the most utilized nanoscale materials in the United States. It is a single-layer carbonaceous nanoscale material with a hexagonal structure. Subtractive synthesis from graphite is common in high-volume manufacturing, with graphene and graphite often present within the same workplace. There is little worker exposure data available to inform risk assessments, particularly for graphene. Dustiness determinations using EN15051-2 Workplace Exposure-Measurement of the Dustiness of Bulk Materials. Part 2: Rotating Drum Method were conducted for two graphene nanoplatelets, two graphene oxides, one few-layered graphene, one furnace carbon black, three natural and five synthetic graphites, and two coals. All 16 test materials were composed mostly of carbon. Dustiness determinations were compared to established thresholds for the inhalable, thoracic, and respirable particle size fractions. Measurements of specific surface area, moisture content, and unconsolidated bulk density were further obtained. Particles were imaged through scanning electron microscopy. The EN15051-2 test is a gentle gravity-induced procedure where the test material falls a limited distance. Dustiness determinations resulted in 2.2% or less of the test material collected in the inhalable size fraction, 0.89% or less in the thoracic, and 0.37% or less in the respirable subfraction. The thoracic fraction constituted ∼31% of the inhalable fraction overall. The masses of four of five graphenes were below the gravimetric limit of detection of 0.57 µg in the respirable size fraction. Contributing factors were the gentle nature of the test and low unconsolidated bulk densities (5.9 to 174 kg/m3) for the nanoscale materials, resulting in 0.21 to 6.1 g loaded masses. Modest enhancements to the testing protocol could potentially improve quantification for low-density materials. All test materials and quantifiable size fractions were classified as moderate or high dustiness on a mg/kg basis. The carbonaceous materials in this study have a moderate to high propensity of becoming airborne when subjected to a gentle gravity-induced stimulus. Without adequate controls to prevent dust emissions, handling could result in inhalation, dermal, and mucous membrane exposures as well as present slip, electrical, fire, and dust explosion hazards.

石墨烯和石墨的粉尘。
石墨烯是美国应用最广泛的纳米材料之一。它是一种单层碳纳米级材料,具有六边形结构。石墨减法合成在大批量生产中很常见,石墨烯和石墨经常出现在同一个工作场所。可用于风险评估的工人暴露数据很少,尤其是石墨烯暴露数据。使用EN15051-2工作场所暴露-散装物料粉尘测量进行粉尘测定。第二部分:转鼓法对两种石墨烯纳米片、两种氧化石墨烯、一种少层石墨烯、一种炉炭黑、三种天然石墨和五种合成石墨以及两种煤进行了实验。所有16种测试材料主要由碳组成。将粉尘测定值与可吸入、胸部和可呼吸颗粒大小分数的既定阈值进行比较。进一步获得了比表面积、水分含量和松散容重的测量结果。通过扫描电子显微镜对颗粒进行成像。EN15051-2测试是一个温和的重力诱导程序,测试材料落在有限的距离上。粉尘测定结果表明,2.2%或更少的测试材料收集在可吸入的大小部分,0.89%或更少在胸部,0.37%或更少在可呼吸的亚部分。胸部部分占可吸入部分的31%。在可吸入颗粒中,5个石墨烯中有4个的质量低于0.57µg的重量检测限。影响因素是测试的温和性质和纳米级材料的低松散堆积密度(5.9至174 kg/m3),导致0.21至6.1 g负载质量。对测试方案的适度改进可能潜在地改善低密度材料的量化。所有试验材料和可量化的粒径分数按mg/kg划分为中等或高粉尘。本研究中的碳质材料在受到轻微的重力诱导刺激时具有中等到高度的空气传播倾向。如果没有适当的控制措施来防止粉尘排放,处理可能会导致吸入、皮肤和粘膜暴露,以及出现滑倒、电气、火灾和粉尘爆炸危险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Occupational and Environmental Hygiene
Journal of Occupational and Environmental Hygiene 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
3.30
自引率
10.00%
发文量
81
审稿时长
12-24 weeks
期刊介绍: The Journal of Occupational and Environmental Hygiene ( JOEH ) is a joint publication of the American Industrial Hygiene Association (AIHA®) and ACGIH®. The JOEH is a peer-reviewed journal devoted to enhancing the knowledge and practice of occupational and environmental hygiene and safety by widely disseminating research articles and applied studies of the highest quality. The JOEH provides a written medium for the communication of ideas, methods, processes, and research in core and emerging areas of occupational and environmental hygiene. Core domains include, but are not limited to: exposure assessment, control strategies, ergonomics, and risk analysis. Emerging domains include, but are not limited to: sensor technology, emergency preparedness and response, changing workforce, and management and analysis of "big" data.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书