Leveraging ECG foundation models in critical care for sinus rhythm and atrial fibrillation classification.

IF 2.9 Q2 CRITICAL CARE MEDICINE
Maria Galanty, Michiel Hulleman, Merijn C Reuland, Björn van der Ster, Alexander P J Vlaar, Clara I Sánchez
{"title":"Leveraging ECG foundation models in critical care for sinus rhythm and atrial fibrillation classification.","authors":"Maria Galanty, Michiel Hulleman, Merijn C Reuland, Björn van der Ster, Alexander P J Vlaar, Clara I Sánchez","doi":"10.1186/s40635-026-00949-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Recent advances in deep learning have led to the development of ECG foundation models (ECG-FMs) trained with self-supervised learning, which can extract generalizable representations from large-scale data. In this study, we evaluated the performance of these ECG-FMs in detecting atrial fibrillation and sinus rhythm during continuous monitoring of intensive care unit (ICU) patients, using data from Amsterdam University Medical Center (Amsterdam UMC). Our three-stage study: (i) used within-dataset classification performance on public PhysioNet datasets as an indirect proxy for label consistency, (ii) tested off-the-shelf fine-tuned ECG-FMs on ICU data, and (iii) fine-tuned ECG-FM on curated public datasets, with and without weakly labelled in-house ICU data.</p><p><strong>Results: </strong>Off-the-shelf model showed limited transferability (F1 = 0.68 for sinus rhythm (SR), 0.52 for atrial fibrillation (AF)). Fine-tuning on consistent public datasets achieved robust performance (F1 = 0.91 for SR, 0.82 for AF), while adding weakly labelled ICU data further improved recall at some cost to precision. Performance remained stable across varying ECG lead configurations, supporting adaptability to heterogeneous inputs.</p><p><strong>Conclusions: </strong>These findings indicate that off-the-shelf pre-trained ECG-FMs do not generalise well to continuous monitoring in ICU populations; however, after targeted fine-tuning, they can achieve strong performance even in unseen cohorts, underscoring the importance of high-quality fine-tuning data and rigorous local validation.</p>","PeriodicalId":13750,"journal":{"name":"Intensive Care Medicine Experimental","volume":"14 1","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2026-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13518658/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Intensive Care Medicine Experimental","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40635-026-00949-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Recent advances in deep learning have led to the development of ECG foundation models (ECG-FMs) trained with self-supervised learning, which can extract generalizable representations from large-scale data. In this study, we evaluated the performance of these ECG-FMs in detecting atrial fibrillation and sinus rhythm during continuous monitoring of intensive care unit (ICU) patients, using data from Amsterdam University Medical Center (Amsterdam UMC). Our three-stage study: (i) used within-dataset classification performance on public PhysioNet datasets as an indirect proxy for label consistency, (ii) tested off-the-shelf fine-tuned ECG-FMs on ICU data, and (iii) fine-tuned ECG-FM on curated public datasets, with and without weakly labelled in-house ICU data.

Results: Off-the-shelf model showed limited transferability (F1 = 0.68 for sinus rhythm (SR), 0.52 for atrial fibrillation (AF)). Fine-tuning on consistent public datasets achieved robust performance (F1 = 0.91 for SR, 0.82 for AF), while adding weakly labelled ICU data further improved recall at some cost to precision. Performance remained stable across varying ECG lead configurations, supporting adaptability to heterogeneous inputs.

Conclusions: These findings indicate that off-the-shelf pre-trained ECG-FMs do not generalise well to continuous monitoring in ICU populations; however, after targeted fine-tuning, they can achieve strong performance even in unseen cohorts, underscoring the importance of high-quality fine-tuning data and rigorous local validation.

利用心电图基础模型对窦性心律和心房颤动进行重症监护分类。
背景:深度学习的最新进展导致了用自监督学习训练的心电基础模型(ECG- fms)的发展,该模型可以从大规模数据中提取可推广的表征。在这项研究中,我们使用阿姆斯特丹大学医学中心(Amsterdam UMC)的数据,评估了这些ECG-FMs在重症监护病房(ICU)患者连续监测期间检测心房颤动和窦性心律的性能。我们的研究分为三个阶段:(i)在公共PhysioNet数据集上使用数据集内分类性能作为标签一致性的间接代理,(ii)在ICU数据上测试现成的微调ECG-FM,以及(iii)在管理的公共数据集上微调ECG-FM,有或没有弱标记的内部ICU数据。结果:现成模型的可移植性有限(窦性心律(SR) F1 = 0.68,心房颤动(AF) F1 = 0.52)。在一致的公共数据集上进行微调获得了稳健的性能(SR的F1 = 0.91, AF的F1 = 0.82),而添加弱标记ICU数据进一步提高了召回率,但代价是准确性。性能在不同的ECG导联配置中保持稳定,支持对异构输入的适应性。结论:这些发现表明,现成的预训练脑电图功能仪不能很好地推广到ICU人群的持续监测中;然而,经过有针对性的微调后,即使在未见过的队列中,它们也可以获得强大的性能,这强调了高质量微调数据和严格的本地验证的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Intensive Care Medicine Experimental
Intensive Care Medicine Experimental CRITICAL CARE MEDICINE-
CiteScore
5.10
自引率
2.90%
发文量
48
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书