Remodel the Failed Trifecta or Not: That Is a Question.

Yi-Lin Tsai, Ching-Wei Lee, Su-Chan Chen, Chun-Chin Chang, Tai-Wei Chen, Chiao-Po Hsu, Shih-Hsien Sung
{"title":"Remodel the Failed Trifecta or Not: That Is a Question.","authors":"Yi-Lin Tsai, Ching-Wei Lee, Su-Chan Chen, Chun-Chin Chang, Tai-Wei Chen, Chiao-Po Hsu, Shih-Hsien Sung","doi":"10.1002/ccd.70830","DOIUrl":null,"url":null,"abstract":"<p><p>Using a high-pressure balloon to do bioprosthetic valve remodeling (BVR) for a failed surgical non-fracturable aortic valve is thought to improve the expansion of a transcatheter heart valve (THV) during valve-in-valve transcatheter aortic valve replacement (ViV-TAVR). However, the risks and benefits of this approach remain under debate. We present two cases of failed bioprosthetic aortic valves (Trifecta 19 mm and 21 mm, Abbott Vascular) receiving ViV-TAVR using balloon-expandable valves (Sapien 3 20-mm, Edwards Lifesciences). In one patient, an ATLAS GOLD balloon catheter (20 mm, BD, Franklin Lakes, New Jersey, USA) was used to do BVR. In the other patient, a double-tap technique with the same volume balloon post-dilatation was performed without BVR. Both procedures were successful, with notable clinical improvement. The post-TAVR computed tomography and transthoracic echocardiogram were performed 1 month after the procedure which demonstrated comparable hemodynamic results; however, the THV deformation was more pronounced in the patient who underwent BVR. Importantly, the THV-to-coronary ostium distance in this patient decreased unexpectedly from 5 mm to near 0 mm over right coronary artery. These cases illustrate that using a high-pressure balloon to perform BVR in a non-fracturable surgical valve had limited impact on THV expansion at the annular level. Conversely, unpredictable over-expansion of the THV in the outflow portion may pose an increased risk to the coronaries, even when the valve-to-coronary distance is long prior to the valve-in-valve TAVR procedure.</p>","PeriodicalId":520583,"journal":{"name":"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions","volume":" ","pages":"1712-1716"},"PeriodicalIF":0.0000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ccd.70830","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Using a high-pressure balloon to do bioprosthetic valve remodeling (BVR) for a failed surgical non-fracturable aortic valve is thought to improve the expansion of a transcatheter heart valve (THV) during valve-in-valve transcatheter aortic valve replacement (ViV-TAVR). However, the risks and benefits of this approach remain under debate. We present two cases of failed bioprosthetic aortic valves (Trifecta 19 mm and 21 mm, Abbott Vascular) receiving ViV-TAVR using balloon-expandable valves (Sapien 3 20-mm, Edwards Lifesciences). In one patient, an ATLAS GOLD balloon catheter (20 mm, BD, Franklin Lakes, New Jersey, USA) was used to do BVR. In the other patient, a double-tap technique with the same volume balloon post-dilatation was performed without BVR. Both procedures were successful, with notable clinical improvement. The post-TAVR computed tomography and transthoracic echocardiogram were performed 1 month after the procedure which demonstrated comparable hemodynamic results; however, the THV deformation was more pronounced in the patient who underwent BVR. Importantly, the THV-to-coronary ostium distance in this patient decreased unexpectedly from 5 mm to near 0 mm over right coronary artery. These cases illustrate that using a high-pressure balloon to perform BVR in a non-fracturable surgical valve had limited impact on THV expansion at the annular level. Conversely, unpredictable over-expansion of the THV in the outflow portion may pose an increased risk to the coronaries, even when the valve-to-coronary distance is long prior to the valve-in-valve TAVR procedure.

是否重塑失败的三连冠:这是一个问题。
使用高压球囊对手术失败的非破裂主动脉瓣进行生物瓣膜重塑(BVR)被认为可以改善经导管心脏瓣膜置换术(ViV-TAVR)中经导管心脏瓣膜(THV)的扩张。然而,这种方法的风险和收益仍然存在争议。我们报告了两例失败的生物人工主动脉瓣(Trifecta 19mm和21mm,雅培血管)使用球囊可膨胀瓣膜(Sapien 3 20mm,爱德华兹生命科学)接受ViV-TAVR。1例患者使用ATLAS GOLD球囊导管(20mm, BD, Franklin Lakes, New Jersey, USA)行BVR。在另一名患者中,在没有BVR的情况下,使用相同容量球囊进行扩张后的双重穿刺技术。两种手术均成功,临床改善显著。术后1个月进行tavr后计算机断层扫描和经胸超声心动图,血流动力学结果相当;然而,在接受BVR的患者中,THV变形更为明显。重要的是,该患者的thv到冠状动脉口的距离在右冠状动脉上出人意料地从5mm下降到接近0 mm。这些病例表明,在非骨折外科瓣膜中使用高压球囊进行BVR对环空水平的THV扩张影响有限。相反,流出部分THV不可预测的过度扩张可能会增加冠状动脉的风险,即使在瓣膜-冠状动脉距离较长的瓣膜-瓣膜TAVR手术之前也是如此。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书