A novel transscleral polypropylene loop rescue technique for preservation of a Carlevale intraocular lens after anchor plug rupture.

Q3 Medicine
Patrizio Bernardinelli, Martina Leonetti, Stanislao Rizzo
{"title":"A novel transscleral polypropylene loop rescue technique for preservation of a Carlevale intraocular lens after anchor plug rupture.","authors":"Patrizio Bernardinelli, Martina Leonetti, Stanislao Rizzo","doi":"10.1097/ICB.0000000000001972","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To describe a novel rescue technique for management of intraoperative rupture of a Carlevale FIL SSF IOL anchor-shaped plug using transscleral 10-0 polypropylene loop fixation.</p><p><strong>Methods: </strong>A 72-year-old woman underwent pars plana vitrectomy and secondary implantation of a Carlevale FIL SSF intraocular lens following complicated cataract surgery associated with posterior capsular rupture and retained lens fragments. During externalization of the second anchor plug, intraoperative rupture of the nasal anchor-shaped haptic plug occurred, resulting in posterior displacement of the unsupported haptic segment into the vitreous cavity. To avoid intraocular lens explantation and additional corneal trauma in an already compromised eye, a rescue transscleral fixation technique using a double-armed 10-0 polypropylene loop surrounding the residual haptic segment was performed.</p><p><strong>Results: </strong>The intraocular lens remained well centered and stable throughout the 12-month follow-up period without clinically appreciable tilt or decentration. Best-corrected visual acuity improved from 20/50 preoperatively to 20/30 at 3 months and remained stable thereafter. No cystoid macular edema, retinal complications, conjunctival erosion, suture exposure, or intraocular lens redislocation were observed. Intraocular pressure remained stable during follow-up.</p><p><strong>Conclusion: </strong>Transscleral 10-0 polypropylene loop fixation may represent a simple and effective rescue option in selected cases of Carlevale FIL SSF intraocular lens anchor plug rupture, allowing preservation of the original intraocular lens while avoiding explantation and additional corneal manipulation.</p>","PeriodicalId":53580,"journal":{"name":"Retinal Cases and Brief Reports","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Retinal Cases and Brief Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ICB.0000000000001972","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To describe a novel rescue technique for management of intraoperative rupture of a Carlevale FIL SSF IOL anchor-shaped plug using transscleral 10-0 polypropylene loop fixation.

Methods: A 72-year-old woman underwent pars plana vitrectomy and secondary implantation of a Carlevale FIL SSF intraocular lens following complicated cataract surgery associated with posterior capsular rupture and retained lens fragments. During externalization of the second anchor plug, intraoperative rupture of the nasal anchor-shaped haptic plug occurred, resulting in posterior displacement of the unsupported haptic segment into the vitreous cavity. To avoid intraocular lens explantation and additional corneal trauma in an already compromised eye, a rescue transscleral fixation technique using a double-armed 10-0 polypropylene loop surrounding the residual haptic segment was performed.

Results: The intraocular lens remained well centered and stable throughout the 12-month follow-up period without clinically appreciable tilt or decentration. Best-corrected visual acuity improved from 20/50 preoperatively to 20/30 at 3 months and remained stable thereafter. No cystoid macular edema, retinal complications, conjunctival erosion, suture exposure, or intraocular lens redislocation were observed. Intraocular pressure remained stable during follow-up.

Conclusion: Transscleral 10-0 polypropylene loop fixation may represent a simple and effective rescue option in selected cases of Carlevale FIL SSF intraocular lens anchor plug rupture, allowing preservation of the original intraocular lens while avoiding explantation and additional corneal manipulation.

一种新的经巩膜聚丙烯环抢救技术在锚栓破裂后保存Carlevale人工晶状体。
目的:介绍一种经巩膜10-0聚丙烯环固定治疗术中Carlevale FIL SSF IOL锚状塞破裂的新抢救技术。方法:一名72岁的女性在白内障术后并发后囊膜破裂和晶状体碎片残留后行玻璃体切除和二次人工晶状体植入术。在第二锚塞外化过程中,术中发生鼻锚状触觉塞破裂,导致无支撑的触觉段后侧移位到玻璃体腔内。为了避免人工晶状体移植和对已经受损的眼睛造成额外的角膜创伤,我们采用了一种救援的经巩膜固定技术,使用双臂10-0聚丙烯环包围剩余的触觉节段。结果:在12个月的随访期间,人工晶状体中心稳定,无明显的倾斜或脱位。最佳矫正视力由术前的20/50提高到3个月时的20/30,术后保持稳定。未见黄斑囊样水肿、视网膜并发症、结膜糜烂、缝合线暴露或人工晶状体再脱位。随访期间眼压保持稳定。结论:经巩膜10-0聚丙烯环固定术可能是一种简单有效的治疗Carlevale FIL - SSF人工晶状体锚栓破裂病例的方法,可以保留原有的人工晶状体,同时避免取出和额外的角膜操作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Retinal Cases and Brief Reports
Retinal Cases and Brief Reports Medicine-Ophthalmology
CiteScore
2.10
自引率
0.00%
发文量
342
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书