Hyperintense Signals in Cerebral Blood Flow Maps of Mice Acquired with Pseudo-continuous Arterial Spin Labeling MR Imaging.

IF 3.2
Xiuli Yang, Yuguo Li, Adnan Bibic, Zhiliang Wei
{"title":"Hyperintense Signals in Cerebral Blood Flow Maps of Mice Acquired with Pseudo-continuous Arterial Spin Labeling MR Imaging.","authors":"Xiuli Yang, Yuguo Li, Adnan Bibic, Zhiliang Wei","doi":"10.2463/mrms.mp.2026-0023","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Pseudo-continuous arterial spin labeling (pCASL) MRI is a widely used, noninvasive, contrast-agent-free technique for measuring cerebral blood flow (CBF) and assessing vascular dysfunction across diverse clinical settings and murine disease models. In practice, arterial-transit artifacts that generate hyperintense signal in CBF maps warrant careful consideration. While these effects are well characterized in humans, they are less well understood in mice owing to the marked interspecies physiological differences.</p><p><strong>Methods: </strong>To address this knowledge gap, we systematically characterized pCASL hyperintense signal as a function of post-labeling delay (PLD) and crusher-gradient strength in mice. Numerical simulations were also performed to validate the experimental findings.</p><p><strong>Results: </strong>We found that hyperintense signals in mice extend to arteries, major veins, and ventricular structures. Such a pattern was different from human pCASL images, where hyperintense signals are predominantly present in arteries. Statistical analyses supported a PLD of 500 milliseconds as a pragmatic balance between detection sensitivity and suppression of vascular contamination. Additional experiments and numerical simulations showed that, within the tested range, stronger crusher gradients provided little extra vascular suppression-primarily because large vessel calibers relative to small voxels limit intravoxel phase dispersion.</p><p><strong>Conclusion: </strong>These findings refine the interpretation of murine pCASL signals and facilitate more accurate perfusion imaging in preclinical pathophysiological studies.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":"25 4","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13683968/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2026-0023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Pseudo-continuous arterial spin labeling (pCASL) MRI is a widely used, noninvasive, contrast-agent-free technique for measuring cerebral blood flow (CBF) and assessing vascular dysfunction across diverse clinical settings and murine disease models. In practice, arterial-transit artifacts that generate hyperintense signal in CBF maps warrant careful consideration. While these effects are well characterized in humans, they are less well understood in mice owing to the marked interspecies physiological differences.

Methods: To address this knowledge gap, we systematically characterized pCASL hyperintense signal as a function of post-labeling delay (PLD) and crusher-gradient strength in mice. Numerical simulations were also performed to validate the experimental findings.

Results: We found that hyperintense signals in mice extend to arteries, major veins, and ventricular structures. Such a pattern was different from human pCASL images, where hyperintense signals are predominantly present in arteries. Statistical analyses supported a PLD of 500 milliseconds as a pragmatic balance between detection sensitivity and suppression of vascular contamination. Additional experiments and numerical simulations showed that, within the tested range, stronger crusher gradients provided little extra vascular suppression-primarily because large vessel calibers relative to small voxels limit intravoxel phase dispersion.

Conclusion: These findings refine the interpretation of murine pCASL signals and facilitate more accurate perfusion imaging in preclinical pathophysiological studies.

伪连续动脉自旋标记磁共振成像获得小鼠脑血流图中的高信号。
目的:伪连续动脉自旋标记(pCASL) MRI是一种广泛使用的、无创的、无造影剂的技术,用于测量脑血流量(CBF)和评估不同临床环境和小鼠疾病模型中的血管功能障碍。实际上,在脑血流图中产生高信号的动脉过境伪影需要仔细考虑。虽然这些影响在人类中有很好的特征,但由于物种间明显的生理差异,它们在小鼠中的作用还不太清楚。方法:为了解决这一知识空白,我们系统地表征了pCASL高信号作为标记后延迟(PLD)和破碎梯度强度的函数。数值模拟验证了实验结果。结果:我们发现小鼠的高信号延伸到动脉、大静脉和心室结构。这种模式与人类pCASL图像不同,后者的高信号主要存在于动脉中。统计分析支持500毫秒的PLD作为检测灵敏度和抑制血管污染之间的实用平衡。额外的实验和数值模拟表明,在测试范围内,较强的破碎梯度几乎没有提供额外的血管抑制,主要是因为相对于小体素的大血管直径限制了体素内的相位分散。结论:这些发现完善了小鼠pCASL信号的解释,有助于临床前病理生理研究中更准确的灌注成像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书