{"title":"[Establishment and validation of an LC-MS/MS-based determination method for 17-hydroxyprogesterone in canine serum].","authors":"Sebastian Naczenski, Ruth Klein, Andrea Hildebrand","doi":"10.1055/a-2854-7332","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>A reliable determination of steroid hormones such as 17-hydroxyprogesterone has long been restricted by the limitations of immunological methods. Assays such as enzyme-linked immunosorbent assay (ELISA), radioimmunoassay (RIA) or chemiluminescence immunoassay (CLIA) show significant cross-reactions, interferences and pronounced variability depending on the test, which limits their diagnostic value.</p><p><strong>Background and objective: </strong>The aim of this work was the methodological establishment and validation of an LC-MS/MS-based determination method for 17-hydroxyprogesterone in order to provide a specific and robust alternative to immunological test systems.</p><p><strong>Material and methods: </strong>The method was developed using stable isotope standards and included systematic testing of linearity, sensitivity, precision, recovery, and matrix effects. Subsequently, initial canine serum samples were analyzed as part of routine diagnostics to illustrate its applicability in a veterinary setting.</p><p><strong>Results: </strong>The method demonstrated excellent analytical performance with a detection limit of 0.044 ng/ml, high linearity (R²>0.999) and low coefficients of variation (<5%). Cross-reactions, as observed with immunological systems, were ruled out.</p><p><strong>Conclusion and clinical relevance: </strong>With the establishment of a LC-MS/MS-based 17-hydroxyprogesterone determination method, a highly specific and precise technique is available, which is in contrast to immunologically based test systems. It thus provides a reliable basis for canine endocrinologic diagnostics and steroid hormone analysis.</p>","PeriodicalId":520818,"journal":{"name":"Tierarztliche Praxis. Ausgabe K, Kleintiere/Heimtiere","volume":" ","pages":"344-349"},"PeriodicalIF":0.5000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13652636/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tierarztliche Praxis. Ausgabe K, Kleintiere/Heimtiere","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2854-7332","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/19 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objective: A reliable determination of steroid hormones such as 17-hydroxyprogesterone has long been restricted by the limitations of immunological methods. Assays such as enzyme-linked immunosorbent assay (ELISA), radioimmunoassay (RIA) or chemiluminescence immunoassay (CLIA) show significant cross-reactions, interferences and pronounced variability depending on the test, which limits their diagnostic value.

Background and objective: The aim of this work was the methodological establishment and validation of an LC-MS/MS-based determination method for 17-hydroxyprogesterone in order to provide a specific and robust alternative to immunological test systems.

Material and methods: The method was developed using stable isotope standards and included systematic testing of linearity, sensitivity, precision, recovery, and matrix effects. Subsequently, initial canine serum samples were analyzed as part of routine diagnostics to illustrate its applicability in a veterinary setting.

Results: The method demonstrated excellent analytical performance with a detection limit of 0.044 ng/ml, high linearity (R²>0.999) and low coefficients of variation (<5%). Cross-reactions, as observed with immunological systems, were ruled out.

Conclusion and clinical relevance: With the establishment of a LC-MS/MS-based 17-hydroxyprogesterone determination method, a highly specific and precise technique is available, which is in contrast to immunologically based test systems. It thus provides a reliable basis for canine endocrinologic diagnostics and steroid hormone analysis.

[基于LC-MS/ ms的犬血清中17-羟孕酮含量测定方法的建立与验证]。
背景与目的:17-羟孕酮等类固醇激素的可靠测定一直受到免疫学方法的限制。酶联免疫吸附测定(ELISA)、放射免疫测定(RIA)或化学发光免疫测定(CLIA)等检测显示出明显的交叉反应、干扰和明显的差异,这限制了它们的诊断价值。背景和目的:本研究的目的是建立和验证一种基于LC-MS/ ms的17-羟孕酮测定方法,以便为免疫检测系统提供一种特异性和健壮的替代方法。材料和方法:该方法采用稳定同位素标准,包括线性、灵敏度、精密度、回收率和基质效应的系统测试。随后,初步犬血清样本作为常规诊断的一部分进行分析,以说明其在兽医环境中的适用性。结果:该方法检测限为0.044 ng/ml,线性度高(R²>0.999),变异系数低(结论及临床意义:建立了基于LC-MS/ ms的17-羟孕酮检测方法,具有较高的特异性和精密度,是基于免疫学的检测系统所不能及的。为犬类内分泌诊断和类固醇激素分析提供了可靠的依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书