Discrepancies in widely used serological methods to detect Borrelia infections may cause missed Lyme diagnoses.

IF 2
Elena Volokhina, Annette Stemerding, Yesper Smits, Jordi Lankhof, Milou Kouwijzer, Anja Garritsen
{"title":"Discrepancies in widely used serological methods to detect <i>Borrelia</i> infections may cause missed Lyme diagnoses.","authors":"Elena Volokhina, Annette Stemerding, Yesper Smits, Jordi Lankhof, Milou Kouwijzer, Anja Garritsen","doi":"10.1177/10815589261483668","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate diagnosis of Lyme disease, caused by <i>Borrelia burgdorferi</i>, is essential for timely treatment and prevention of long-term complications. This study investigates discrepancies in widely used serological assays and their impact on diagnostic sensitivity in high-risk populations. We analyzed samples from an annual Lyme screening program conducted by Innatoss Laboratories between November 2020 and May 2022, targeting individuals with occupational exposure to ticks.</p><p><strong>Methods: </strong>A retrospective cohort of 60 positive serum samples from 57 participants (aged 23-64) was evaluated using three tier one protocols: EUROIMMUN/ZEUS enzyme-linked immunosorbent assay (ELISA), SERION ELISA, and Diasorin chemiluminescence immunoassay, followed by Viramed immunoblots for confirmation.</p><p><strong>Results: </strong>Our findings revealed significant variability in test sensitivity: the EUROIMMUN/ZEUS protocol detected 96.8% of cases, compared to 84.1% for SERION (<i>p</i> = 0.023) and 69.8.0% for Diasorin (<i>p</i> < 0.001). Notably, six recent <i>Borrelia</i> infections were missed due to test selection, as confirmed by longitudinal comparison with previous samples. One case study illustrated the clinical consequences of missed diagnoses, including delayed treatment and symptom persistence.</p><p><strong>Conclusion: </strong>These results underscore the need for standardized serological protocols and routine longitudinal sample comparison. We propose the establishment of a consensus panel to define assay performance criteria and recommend integration of electronic health records with laboratory systems to enable automated historical data retrieval. Adoption of more sensitive testing strategies and harmonized interpretation guidelines could significantly improve diagnostic accuracy and patient outcomes in Lyme disease.</p>","PeriodicalId":520677,"journal":{"name":"Journal of investigative medicine : the official publication of the American Federation for Clinical Research","volume":" ","pages":"10815589261483668"},"PeriodicalIF":2.0000,"publicationDate":"2026-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of investigative medicine : the official publication of the American Federation for Clinical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/10815589261483668","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Accurate diagnosis of Lyme disease, caused by Borrelia burgdorferi, is essential for timely treatment and prevention of long-term complications. This study investigates discrepancies in widely used serological assays and their impact on diagnostic sensitivity in high-risk populations. We analyzed samples from an annual Lyme screening program conducted by Innatoss Laboratories between November 2020 and May 2022, targeting individuals with occupational exposure to ticks.

Methods: A retrospective cohort of 60 positive serum samples from 57 participants (aged 23-64) was evaluated using three tier one protocols: EUROIMMUN/ZEUS enzyme-linked immunosorbent assay (ELISA), SERION ELISA, and Diasorin chemiluminescence immunoassay, followed by Viramed immunoblots for confirmation.

Results: Our findings revealed significant variability in test sensitivity: the EUROIMMUN/ZEUS protocol detected 96.8% of cases, compared to 84.1% for SERION (p = 0.023) and 69.8.0% for Diasorin (p < 0.001). Notably, six recent Borrelia infections were missed due to test selection, as confirmed by longitudinal comparison with previous samples. One case study illustrated the clinical consequences of missed diagnoses, including delayed treatment and symptom persistence.

Conclusion: These results underscore the need for standardized serological protocols and routine longitudinal sample comparison. We propose the establishment of a consensus panel to define assay performance criteria and recommend integration of electronic health records with laboratory systems to enable automated historical data retrieval. Adoption of more sensitive testing strategies and harmonized interpretation guidelines could significantly improve diagnostic accuracy and patient outcomes in Lyme disease.

快报:广泛使用的血清学方法检测伯氏疏螺旋体感染的差异可能导致莱姆病的漏诊。
准确诊断由伯氏疏螺旋体引起的莱姆病,对于及时治疗和预防长期并发症至关重要。本研究调查了广泛使用的血清学检测方法的差异及其对高危人群诊断敏感性的影响。我们分析了Innatoss实验室在2020年11月至2022年5月期间进行的年度莱姆病筛查项目的样本,该项目针对的是职业接触蜱虫的个体。采用三种一级方案:EUROIMMUN/ZEUS ELISA、SERION ELISA和Diasorin CLIA对来自57名参与者(23-64岁)的60份阳性血清样本进行回顾性队列评估,随后采用Viramed免疫印迹进行确认。我们的研究结果显示了检测灵敏度的显著差异:EUROIMMUN/ZEUS方案检测到96.8%的病例,而SERION检测到84.1% (p = 0.023),而Diasorin检测到69.8.0% (p = 0.023)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书