Spurious life-threatening hypermagnesemia caused by a preanalytical error in an intensive care unit: a case report.

IF 1.8
Biochemia medica Pub Date : 2026-10-15 Epub Date: 2026-08-10 DOI:10.11613/BM.2026.031001
Tara Rolić, Inja Pavlić, Ivana Sarić
{"title":"Spurious life-threatening hypermagnesemia caused by a preanalytical error in an intensive care unit: a case report.","authors":"Tara Rolić, Inja Pavlić, Ivana Sarić","doi":"10.11613/BM.2026.031001","DOIUrl":null,"url":null,"abstract":"<p><p>Accurate measurement of electrolytes is essential in critically ill patients. Magnesium (Mg) concentrations are particularly vulnerable to preanalytical errors, which may lead to life-threatening misinterpretation. A 57-year-old woman was admitted to the intensive care unit (ICU) due to acute decompensated heart failure and atrial fibrillation. On the second day of ICU hospitalization, serum samples analyzed in the emergency laboratory revealed critically low sodium (Na), potassium (K), and chloride (Cl) concentrations, accompanied by extremely elevated Mg concentrations that were considered incompatible with life. Given the discrepancy between life-threateningly high Mg concentrations and the patient's stable clinical condition, as confirmed by clinicians, who reported no signs of hyporeflexia, respiratory depression, or other symptoms of Mg toxicity, the laboratory medicine professional (LMP) initiated urgent communication with the clinical staff and recommended repeating the blood draw and all analyses. A reflex glucose measurement revealed a markedly elevated concentration (55.4 mmol/L), indicating contamination with a glucose infusion. The repeated analysis showed Mg and other electrolyte concentrations within reference ranges. Further investigation confirmed that blood sampling had been performed from the same arm and venous catheter through which infusion was being administered. The abnormal laboratory findings were explained by a preanalytical error caused by blood sampling during active infusion. This case emphasizes the importance of appropriate documentation of ongoing intravenous therapy and blood sampling conditions, as well as communication between the LMP and clinical staff. Awareness of preanalytical variables is essential to prevent misinterpretation of laboratory results and inappropriate patient treatment.</p>","PeriodicalId":94370,"journal":{"name":"Biochemia medica","volume":"36 3","pages":"031001"},"PeriodicalIF":1.8000,"publicationDate":"2026-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13489495/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biochemia medica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11613/BM.2026.031001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/10 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Accurate measurement of electrolytes is essential in critically ill patients. Magnesium (Mg) concentrations are particularly vulnerable to preanalytical errors, which may lead to life-threatening misinterpretation. A 57-year-old woman was admitted to the intensive care unit (ICU) due to acute decompensated heart failure and atrial fibrillation. On the second day of ICU hospitalization, serum samples analyzed in the emergency laboratory revealed critically low sodium (Na), potassium (K), and chloride (Cl) concentrations, accompanied by extremely elevated Mg concentrations that were considered incompatible with life. Given the discrepancy between life-threateningly high Mg concentrations and the patient's stable clinical condition, as confirmed by clinicians, who reported no signs of hyporeflexia, respiratory depression, or other symptoms of Mg toxicity, the laboratory medicine professional (LMP) initiated urgent communication with the clinical staff and recommended repeating the blood draw and all analyses. A reflex glucose measurement revealed a markedly elevated concentration (55.4 mmol/L), indicating contamination with a glucose infusion. The repeated analysis showed Mg and other electrolyte concentrations within reference ranges. Further investigation confirmed that blood sampling had been performed from the same arm and venous catheter through which infusion was being administered. The abnormal laboratory findings were explained by a preanalytical error caused by blood sampling during active infusion. This case emphasizes the importance of appropriate documentation of ongoing intravenous therapy and blood sampling conditions, as well as communication between the LMP and clinical staff. Awareness of preanalytical variables is essential to prevent misinterpretation of laboratory results and inappropriate patient treatment.

重症监护室分析前错误引起的假性危及生命的高镁血症:一例报告。
准确测量电解质对危重病人至关重要。镁(Mg)浓度特别容易受到分析前错误的影响,这可能导致危及生命的误解。一位57岁的女性因急性失代偿性心力衰竭和心房颤动而被送入重症监护病房(ICU)。在ICU住院的第二天,急诊实验室分析的血清样本显示钠(Na)、钾(K)和氯(Cl)浓度极低,并伴有Mg浓度极高,被认为与生命不相容。鉴于危及生命的高Mg浓度与患者稳定的临床状况之间存在差异,临床医生报告无反射减退、呼吸抑制或其他Mg毒性症状,实验室医学专业人员(LMP)与临床工作人员紧急沟通,并建议重复抽血和所有分析。反射性葡萄糖测量显示浓度明显升高(55.4 mmol/L),表明葡萄糖输注污染。反复分析表明Mg和其他电解质浓度在参考范围内。进一步的调查证实,从正在进行输液的同一只手臂和静脉导管进行了血液采样。异常的实验室结果是由主动输注期间血液采样引起的分析前错误解释的。该病例强调了适当记录正在进行的静脉注射治疗和血液采样条件的重要性,以及LMP和临床工作人员之间的沟通。分析前变量的认识是必不可少的,以防止实验室结果的误解和不适当的病人治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书