{"title":"[Continuous glucose monitoring and automated insulin dosing systems in clinical routine].","authors":"Annie Mathew, Dagmar Führer","doi":"10.1007/s00108-026-02166-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Continuous glucose monitoring (CGM), connected insulin pens, insulin pumps, and automated insulin delivery (AID) systems enable increasingly data-driven and partially automated diabetes management.</p><p><strong>Objective: </strong>A practice-oriented evaluation of the indications, clinical benefits, and safety of modern diabetes technologies.</p><p><strong>Materials and methods: </strong>An analysis of current guidelines, position papers, randomized controlled trials, meta-analyses, and selected real-world data.</p><p><strong>Results and conclusion: </strong>Diabetes technologies should be offered according to individual needs, abilities, preferences, and life circumstances and, when appropriate, implemented early, including at the time of diagnosis. CGM supports diabetes treatment in individuals receiving insulin therapy, those at significant risk of hypoglycemia, and clinical situations in which CGM data improve clinical decision-making. Connected insulin pens facilitate the documentation and combined review of glucose and insulin data. AID systems are preferred for individuals with type 1 diabetes and also represent an effective therapeutic option for those with type 2 diabetes receiving intensive insulin therapy. Regular training, standardized data review, and a back-up plan are required. Patients may continue using their own diabetes devices in the hospital when clinically appropriate and institutional processes are in place. Future developments aim to reduce user burden, improve interoperability, and increase time in range (TIR).</p>","PeriodicalId":73385,"journal":{"name":"Innere Medizin (Heidelberg, Germany)","volume":" ","pages":"1063-1072"},"PeriodicalIF":0.6000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Innere Medizin (Heidelberg, Germany)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00108-026-02166-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/21 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Continuous glucose monitoring (CGM), connected insulin pens, insulin pumps, and automated insulin delivery (AID) systems enable increasingly data-driven and partially automated diabetes management.

Objective: A practice-oriented evaluation of the indications, clinical benefits, and safety of modern diabetes technologies.

Materials and methods: An analysis of current guidelines, position papers, randomized controlled trials, meta-analyses, and selected real-world data.

Results and conclusion: Diabetes technologies should be offered according to individual needs, abilities, preferences, and life circumstances and, when appropriate, implemented early, including at the time of diagnosis. CGM supports diabetes treatment in individuals receiving insulin therapy, those at significant risk of hypoglycemia, and clinical situations in which CGM data improve clinical decision-making. Connected insulin pens facilitate the documentation and combined review of glucose and insulin data. AID systems are preferred for individuals with type 1 diabetes and also represent an effective therapeutic option for those with type 2 diabetes receiving intensive insulin therapy. Regular training, standardized data review, and a back-up plan are required. Patients may continue using their own diabetes devices in the hospital when clinically appropriate and institutional processes are in place. Future developments aim to reduce user burden, improve interoperability, and increase time in range (TIR).

[临床常规连续血糖监测和自动胰岛素给药系统]。
背景:连续血糖监测(CGM)、连接胰岛素笔、胰岛素泵和自动胰岛素输送(AID)系统使越来越多的数据驱动和部分自动化的糖尿病管理成为可能。目的:以实践为导向评价现代糖尿病技术的适应症、临床益处和安全性。材料和方法:对当前指南、立场文件、随机对照试验、荟萃分析和选定的真实世界数据进行分析。结果和结论:糖尿病技术应根据个人需求、能力、偏好和生活环境提供,并在适当的情况下尽早实施,包括在诊断时实施。CGM支持接受胰岛素治疗的个体、低血糖风险显著的个体以及CGM数据改善临床决策的临床情况的糖尿病治疗。连接胰岛素笔便于葡萄糖和胰岛素数据的记录和综合审查。AID系统是1型糖尿病患者的首选,也是接受胰岛素强化治疗的2型糖尿病患者的有效治疗选择。定期的培训、标准化的数据审查和备份计划是必需的。当临床适宜且机构程序到位时,患者可继续在医院使用自己的糖尿病装置。未来的发展目标是减少用户负担、提高互操作性和增加范围内时间(TIR)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书