[Selection of the method for additional correction of ametropia after previous femtosecond laser lenticule correction of myopia and myopic astigmatism using CLEAR technique].

Q3 Medicine
T S Kuznetsova, V D Antonuk, S Yu Shchukin, R R Fayzrakhmanov, A A Golyakov
{"title":"[Selection of the method for additional correction of ametropia after previous femtosecond laser lenticule correction of myopia and myopic astigmatism using CLEAR technique].","authors":"T S Kuznetsova, V D Antonuk, S Yu Shchukin, R R Fayzrakhmanov, A A Golyakov","doi":"10.17116/oftalma202614204192","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The study presents 3 options for additional correction of ametropia after previous femtosecond laser correction of myopia and myopic astigmatism using the corneal lenticule extraction for advance refractive correction (CLEAR) technique.</p><p><strong>Material and methods: </strong>The study included 3 patients (3 eyes). After CLEAR surgery, patient 1 had uncorrected visual acuity (UCVA) in the left eye (OS) of 0.8 with correction sph (+)0.25 cyl (+)1.0ax113=1.0; in patient 2 UCVA OS was 0.4 with correction sph (-)1.25 cyl (-)0.25ax134=1.0; in patient 3 UCVA OS was 0.4 with correction cyl (-)1.75-42=1.0. In the first case, the corneal flap was created mechanically, in the second case, a 3D corneal flap edge was created using the Femto Z8 femtosecond laser system, and in the third case, a 2D corneal flap edge was created using the same system. Excimer laser ablation of residual ametropia was then performed in all cases.</p><p><strong>Results: </strong>The surgeries were completed without complications. UCVA of 1.0 was achieved in all cases.</p><p><strong>Conclusion: </strong>Post-CLEAR ametropia correction is possible by shaping the edge of the corneal flap using a mechanical method, as well as using the Femto Z8 femtosecond laser system with the \"side-cut-only\" and \"border-cut-only\" programs.</p>","PeriodicalId":23529,"journal":{"name":"Vestnik oftalmologii","volume":"142 4","pages":"92-98"},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik oftalmologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/oftalma202614204192","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The study presents 3 options for additional correction of ametropia after previous femtosecond laser correction of myopia and myopic astigmatism using the corneal lenticule extraction for advance refractive correction (CLEAR) technique.

Material and methods: The study included 3 patients (3 eyes). After CLEAR surgery, patient 1 had uncorrected visual acuity (UCVA) in the left eye (OS) of 0.8 with correction sph (+)0.25 cyl (+)1.0ax113=1.0; in patient 2 UCVA OS was 0.4 with correction sph (-)1.25 cyl (-)0.25ax134=1.0; in patient 3 UCVA OS was 0.4 with correction cyl (-)1.75-42=1.0. In the first case, the corneal flap was created mechanically, in the second case, a 3D corneal flap edge was created using the Femto Z8 femtosecond laser system, and in the third case, a 2D corneal flap edge was created using the same system. Excimer laser ablation of residual ametropia was then performed in all cases.

Results: The surgeries were completed without complications. UCVA of 1.0 was achieved in all cases.

Conclusion: Post-CLEAR ametropia correction is possible by shaping the edge of the corneal flap using a mechanical method, as well as using the Femto Z8 femtosecond laser system with the "side-cut-only" and "border-cut-only" programs.

[CLEAR技术飞秒激光晶状体矫正近视和近视散光后额外矫正屈光不正方法的选择]。
目的:探讨飞秒激光近视和近视散光提前屈光矫正(CLEAR)技术后,进一步矫正屈光不正的3种选择。材料与方法:纳入3例患者(3只眼)。患者1术后左眼未矫正视力(UCVA) (OS) 0.8,矫正sph (+)0.25 cyl (+)1.0ax113=1.0;患者2 UCVA OS为0.4,校正sph (-)1.25 cycle (-)0.25ax134=1.0;患者3 UCVA OS为0.4,校正周期(-)1.75-42=1.0。在第一个案例中,角膜瓣是机械创建的,在第二个案例中,三维角膜瓣边缘是使用飞秒激光系统创建的,在第三个案例中,使用相同的系统创建了二维角膜瓣边缘。所有病例均行准分子激光消融残余屈光不正。结果:手术顺利完成,无并发症。所有病例的UCVA均达到1.0。结论:采用机械方法对角膜瓣边缘进行整形,同时使用Femto Z8飞秒激光系统进行“仅侧切”和“仅边切”两种方案,可实现术后屈光不正矫正。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Vestnik oftalmologii
Vestnik oftalmologii Medicine-Ophthalmology
CiteScore
0.80
自引率
0.00%
发文量
129
期刊介绍: The journal publishes materials on the diagnosis and treatment of eye diseases, hygiene of vision, prevention of ophthalmic affections, history of Russian ophthalmology, organization of ophthalmological aid to the population, as well as the problems of special equipment. Original scientific articles and surveys on urgent problems of theory and practice of Russian and foreign ophthalmology are published. The journal contains book reviews on ophthalmology, information on the activities of ophthalmologists" scientific societies, chronicle of congresses and conferences.The journal is intended for ophthalmologists and scientific workers dealing with clinical problems of diseases of the eye and physiology of vision.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书