Evaluation of Alysis-001 cuffless blood pressure estimation algorithm against the European Society of Hypertension awake/asleep test criteria in hypertensive patients.
{"title":"Evaluation of Alysis-001 cuffless blood pressure estimation algorithm against the European Society of Hypertension awake/asleep test criteria in hypertensive patients.","authors":"Kazuhiro Hongyo, Atsushi Hirayama, Kosuke Shimizu, Taisuke Ueno, Taku Fujimoto, Akitoshi Hara, Hiroshi Koriyama, Yoichi Takami, Yoshio Iwashima, Ryo Kawasaki, Koichi Yamamoto","doi":"10.1038/s41440-026-02728-z","DOIUrl":null,"url":null,"abstract":"<p><p>Accurate ambulatory blood pressure monitoring (ABPM) is essential for cardiovascular risk assessment and hypertension management, but conventional cuff-based ABPM causes discomfort and sleep disturbance, potentially affecting measurement reliability. The European Society of Hypertension (ESH) established evaluation criteria for cuffless blood pressure devices, with the awake/asleep test as the primary evaluation test for automated wearable devices. This study evaluated whether Alysis-001, a software-based cuffless blood pressure estimation algorithm using sensor data from a wrist-worn device, meets ESH awake/asleep test criteria in hypertensive patients under two data extraction strategies: (1) arm-stabilized periods only ( ≥ 10 s static); (2) including low-intensity activity (high-intensity excluded). We prospectively enrolled 92 hypertensive outpatients receiving antihypertensive treatment who simultaneously wore Alysis Wear and underwent conventional 24-h ABPM; 78 completed the study. Under both strategies, Alysis-001 demonstrated excellent agreement with reference ABPM across all measurement periods, with intraclass correlation coefficients exceeding 0.70 for systolic and diastolic blood pressure. Alysis-001 successfully met all ESH awake/asleep test criteria under both strategies: mean difference between awake-asleep blood pressure changes ≤5 mmHg, standard deviation ≤8 mmHg, and correlation coefficients ≥0.70 for both systolic and diastolic blood pressure. Alysis-001 also demonstrated high sensitivity, specificity, and accuracy in identifying non-dippers under both strategies. To our knowledge, this represents the first evaluation of a Device Type 3 cuffless blood pressure algorithm (automated, wearable, demographic-calibrated, not at heart level) meeting ESH awake/asleep test criteria, suggesting Alysis-001's potential as a clinically viable alternative for ambulatory blood pressure monitoring in hypertensive patients.</p>","PeriodicalId":13029,"journal":{"name":"Hypertension Research","volume":" ","pages":""},"PeriodicalIF":5.0000,"publicationDate":"2026-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hypertension Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1038/s41440-026-02728-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
Accurate ambulatory blood pressure monitoring (ABPM) is essential for cardiovascular risk assessment and hypertension management, but conventional cuff-based ABPM causes discomfort and sleep disturbance, potentially affecting measurement reliability. The European Society of Hypertension (ESH) established evaluation criteria for cuffless blood pressure devices, with the awake/asleep test as the primary evaluation test for automated wearable devices. This study evaluated whether Alysis-001, a software-based cuffless blood pressure estimation algorithm using sensor data from a wrist-worn device, meets ESH awake/asleep test criteria in hypertensive patients under two data extraction strategies: (1) arm-stabilized periods only ( ≥ 10 s static); (2) including low-intensity activity (high-intensity excluded). We prospectively enrolled 92 hypertensive outpatients receiving antihypertensive treatment who simultaneously wore Alysis Wear and underwent conventional 24-h ABPM; 78 completed the study. Under both strategies, Alysis-001 demonstrated excellent agreement with reference ABPM across all measurement periods, with intraclass correlation coefficients exceeding 0.70 for systolic and diastolic blood pressure. Alysis-001 successfully met all ESH awake/asleep test criteria under both strategies: mean difference between awake-asleep blood pressure changes ≤5 mmHg, standard deviation ≤8 mmHg, and correlation coefficients ≥0.70 for both systolic and diastolic blood pressure. Alysis-001 also demonstrated high sensitivity, specificity, and accuracy in identifying non-dippers under both strategies. To our knowledge, this represents the first evaluation of a Device Type 3 cuffless blood pressure algorithm (automated, wearable, demographic-calibrated, not at heart level) meeting ESH awake/asleep test criteria, suggesting Alysis-001's potential as a clinically viable alternative for ambulatory blood pressure monitoring in hypertensive patients.
准确的动态血压监测(ABPM)对于心血管风险评估和高血压管理至关重要,但传统的基于袖带的ABPM会导致不适和睡眠障碍,潜在地影响测量的可靠性。欧洲高血压学会(European Society of Hypertension, ESH)建立了无袖血压装置的评估标准,将清醒/睡眠测试作为自动化可穿戴设备的主要评估测试。本研究在两种数据提取策略下评估基于软件的无袖带血压估计算法Alysis-001是否满足高血压患者的ESH清醒/睡眠测试标准:(1)仅臂稳定期(静态≥10 s);(2)包括低强度活动(不包括高强度活动)。我们前瞻性地招募了92名接受降压治疗的高血压门诊患者,他们同时佩戴analysis Wear并进行常规24小时ABPM;78人完成了这项研究。在这两种策略下,分析-001在所有测量期间都与参考ABPM表现出极好的一致性,收缩压和舒张压的类内相关系数超过0.70。在两种策略下,analysis -001均成功满足ESH清醒/睡眠测试的所有标准:清醒-睡眠血压变化的平均差异≤5 mmHg,标准差≤8 mmHg,收缩压和舒张压的相关系数≥0.70。在两种策略下,分析-001在识别非浸出物方面也显示出高灵敏度、特异性和准确性。据我们所知,这是第一次对符合ESH清醒/睡眠测试标准的设备3型无袖扣血压算法(自动化、可穿戴、人口统计校准,而不是心脏水平)的评估,表明分析-001有可能成为高血压患者动态血压监测的临床可行替代方案。
期刊介绍:
Hypertension Research is the official publication of the Japanese Society of Hypertension. The journal publishes papers reporting original clinical and experimental research that contribute to the advancement of knowledge in the field of hypertension and related cardiovascular diseases. The journal publishes Review Articles, Articles, Correspondence and Comments.