{"title":"Open-face plane orientation of a BioMedtrix biologic fixation acetabular cup can be accurately determined from a lateral radiograph.","authors":"Owen T Fink, Peter J Lotsikas","doi":"10.2460/ajvr.26.05.0236","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To develop and validate a method to calculate biologic fixation (BFX) acetabular cup open-face plane orientation based on measurements from a lateral radiograph.</p><p><strong>Methods: </strong>The formulas describing the open-face plane orientation were derived using geometric arguments and trigonometry. To assess the method, an in vitro plastic model of a pelvis was implanted with a BFX acetabular cup. A lateral radiograph of the implanted model was obtained and used to calculate the cup open-face plane orientation using the derived method. Direct measurement of the open-face plane orientation was performed, and the calculated values were compared to the directly measured values. The procedure was repeated with the cup in a different orientation for each trial.</p><p><strong>Results: </strong>52 trials were performed. The derived calculation method demonstrated high repeatability and reproducibility, with intra- and interobserver intraclass correlation coefficients > 0.94. The direct measurement method demonstrated high reproducibility, with interobserver intraclass correlation coefficients > 0.98. The mean absolute angular difference between the calculated and directly measured orientation vectors was 2.8 ± 1.3°, with 95% of trials within 4.7°.</p><p><strong>Conclusions: </strong>The open-face plane orientation determined by the derived method agreed closely with the directly measured orientation.</p><p><strong>Clinical relevance: </strong>Knowledge of the BFX open-face plane orientation can inform decisions regarding cup revision, help identify complications associated with cup malpositioning, and allow the surgeon to improve their cup placement performance.</p>","PeriodicalId":7754,"journal":{"name":"American journal of veterinary research","volume":" ","pages":"1-10"},"PeriodicalIF":1.6000,"publicationDate":"2026-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of veterinary research","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.2460/ajvr.26.05.0236","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To develop and validate a method to calculate biologic fixation (BFX) acetabular cup open-face plane orientation based on measurements from a lateral radiograph.
Methods: The formulas describing the open-face plane orientation were derived using geometric arguments and trigonometry. To assess the method, an in vitro plastic model of a pelvis was implanted with a BFX acetabular cup. A lateral radiograph of the implanted model was obtained and used to calculate the cup open-face plane orientation using the derived method. Direct measurement of the open-face plane orientation was performed, and the calculated values were compared to the directly measured values. The procedure was repeated with the cup in a different orientation for each trial.
Results: 52 trials were performed. The derived calculation method demonstrated high repeatability and reproducibility, with intra- and interobserver intraclass correlation coefficients > 0.94. The direct measurement method demonstrated high reproducibility, with interobserver intraclass correlation coefficients > 0.98. The mean absolute angular difference between the calculated and directly measured orientation vectors was 2.8 ± 1.3°, with 95% of trials within 4.7°.
Conclusions: The open-face plane orientation determined by the derived method agreed closely with the directly measured orientation.
Clinical relevance: Knowledge of the BFX open-face plane orientation can inform decisions regarding cup revision, help identify complications associated with cup malpositioning, and allow the surgeon to improve their cup placement performance.
期刊介绍:
The American Journal of Veterinary Research supports the collaborative exchange of information between researchers and clinicians by publishing novel research findings that bridge the gulf between basic research and clinical practice or that help to translate laboratory research and preclinical studies to the development of clinical trials and clinical practice. The journal welcomes submission of high-quality original studies and review articles in a wide range of scientific fields, including anatomy, anesthesiology, animal welfare, behavior, epidemiology, genetics, heredity, infectious disease, molecular biology, oncology, pharmacology, pathogenic mechanisms, physiology, surgery, theriogenology, toxicology, and vaccinology. Species of interest include production animals, companion animals, equids, exotic animals, birds, reptiles, and wild and marine animals. Reports of laboratory animal studies and studies involving the use of animals as experimental models of human diseases are considered only when the study results are of demonstrable benefit to the species used in the research or to another species of veterinary interest. Other fields of interest or animals species are not necessarily excluded from consideration, but such reports must focus on novel research findings. Submitted papers must make an original and substantial contribution to the veterinary medicine knowledge base; preliminary studies are not appropriate.