Assessing viscoelastic properties of clear aligners using a geometry-independent indentation method.

IF 6.3 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Bi Wang, Haochen Jiang, Ruihong Cheng, Jiayi Pu, Yanping Cao
{"title":"Assessing viscoelastic properties of clear aligners using a geometry-independent indentation method.","authors":"Bi Wang, Haochen Jiang, Ruihong Cheng, Jiayi Pu, Yanping Cao","doi":"10.1016/j.dental.2026.08.005","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Clear aligners are widely used in digital orthodontics, but their clinical force delivery is governed by the time-dependent viscoelastic behavior of thermoplastic materials. Due to the thin-walled, curved, and geometrically irregular characteristics of clinical aligners, conventional tensile or bending tests and standard indentation analyses cannot reliably recover their intrinsic viscoelastic properties. Thus, the present study aimed to introduce and validate a geometry-independent indentation framework for characterizing the intrinsic viscoelastic response of clear aligners. In the present context, intrinsic viscoelastic properties refer to the reduced relaxation function and its characteristic relaxation spectrum after normalization removes time-independent geometric factors, rather than to the absolute instantaneous modulus.</p><p><strong>Methods: </strong>The proposed method was derived from dimensional analysis and the elastic-viscoelastic correspondence principle. Its validity was examined by finite element simulations of a clinically realistic aligner geometry. Indentation experiments were further conducted on raw thermoplastic films, thermoformed films, as-fabricated aligners, and intraorally used aligners to track the viscoelastic evolution of materials during manufacturing and clinical service.</p><p><strong>Results: </strong>Numerical simulations showed that the normalized creep and relaxation functions obtained from different aligner regions and indenter profiles agreed closely with the prescribed reference functions. Experimental measurements revealed pronounced differences between flat films and shaped aligners, together with position-dependent differences between two regions of the same appliance. These results show that the suggested method can suppress time-independent geometric contributions while retaining spatial variations in the local viscoelastic response.</p><p><strong>Significance: </strong>The suggested indentation method enables minimally destructive, direct characterization of the reduced viscoelastic behavior of intact clear aligners without geometry-specific inverse analysis. By separating time-independent geometric effects from the normalized time-dependent response, the method can also reveal position-dependent viscoelastic characteristics associated with local forming history and clinical wear.</p>","PeriodicalId":298,"journal":{"name":"Dental Materials","volume":" ","pages":""},"PeriodicalIF":6.3000,"publicationDate":"2026-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1016/j.dental.2026.08.005","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Clear aligners are widely used in digital orthodontics, but their clinical force delivery is governed by the time-dependent viscoelastic behavior of thermoplastic materials. Due to the thin-walled, curved, and geometrically irregular characteristics of clinical aligners, conventional tensile or bending tests and standard indentation analyses cannot reliably recover their intrinsic viscoelastic properties. Thus, the present study aimed to introduce and validate a geometry-independent indentation framework for characterizing the intrinsic viscoelastic response of clear aligners. In the present context, intrinsic viscoelastic properties refer to the reduced relaxation function and its characteristic relaxation spectrum after normalization removes time-independent geometric factors, rather than to the absolute instantaneous modulus.

Methods: The proposed method was derived from dimensional analysis and the elastic-viscoelastic correspondence principle. Its validity was examined by finite element simulations of a clinically realistic aligner geometry. Indentation experiments were further conducted on raw thermoplastic films, thermoformed films, as-fabricated aligners, and intraorally used aligners to track the viscoelastic evolution of materials during manufacturing and clinical service.

Results: Numerical simulations showed that the normalized creep and relaxation functions obtained from different aligner regions and indenter profiles agreed closely with the prescribed reference functions. Experimental measurements revealed pronounced differences between flat films and shaped aligners, together with position-dependent differences between two regions of the same appliance. These results show that the suggested method can suppress time-independent geometric contributions while retaining spatial variations in the local viscoelastic response.

Significance: The suggested indentation method enables minimally destructive, direct characterization of the reduced viscoelastic behavior of intact clear aligners without geometry-specific inverse analysis. By separating time-independent geometric effects from the normalized time-dependent response, the method can also reveal position-dependent viscoelastic characteristics associated with local forming history and clinical wear.

使用与几何无关的压痕方法评估透明对准器的粘弹性特性。
目的:透明矫正器广泛应用于指指正畸,但其临床力传递受热塑性材料的粘弹性行为的时间依赖性支配。由于临床矫正器的薄壁、弯曲和几何不规则的特点,常规的拉伸或弯曲测试和标准压痕分析不能可靠地恢复其固有的粘弹性特性。因此,本研究旨在引入和验证一个几何无关的压痕框架,用于表征透明对准器的固有粘弹性响应。在目前的情况下,本征粘弹性是指归一化后的松弛函数及其特征松弛谱,去除与时间无关的几何因素,而不是绝对瞬时模量。方法:根据量纲分析和弹性-粘弹性对应原理推导出该方法。该方法的有效性通过临床实际对准器几何形状的有限元模拟进行了检验。进一步对原料热塑性薄膜、热成型薄膜、预制矫形器和口服矫形器进行压痕实验,以跟踪材料在制造和临床服务过程中的粘弹性演变。结果:数值模拟结果表明,在不同对准器区域和压头剖面上得到的归一化蠕变和松弛函数与规定的参考函数基本一致。实验测量揭示了平面薄膜和形状对准器之间的明显差异,以及同一器具两个区域之间的位置依赖差异。这些结果表明,该方法可以抑制与时间无关的几何贡献,同时保留局部粘弹性响应的空间变化。意义:所建议的压痕方法可以最小限度地破坏性,直接表征完整的透明对准器的减少粘弹性行为,而无需几何特定的逆分析。通过将时间无关的几何效应与标准化的时间相关响应分离,该方法还可以揭示与局部形成历史和临床磨损相关的位置相关的粘弹性特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Dental Materials
Dental Materials 工程技术-材料科学:生物材料
CiteScore
9.80
自引率
10.00%
发文量
290
审稿时长
67 days
期刊介绍: Dental Materials publishes original research, review articles, and short communications. Academy of Dental Materials members click here to register for free access to Dental Materials online. The principal aim of Dental Materials is to promote rapid communication of scientific information between academia, industry, and the dental practitioner. Original Manuscripts on clinical and laboratory research of basic and applied character which focus on the properties or performance of dental materials or the reaction of host tissues to materials are given priority publication. Other acceptable topics include application technology in clinical dentistry and dental laboratory technology. Comprehensive reviews and editorial commentaries on pertinent subjects will be considered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书