Evaluating Powder Deposition in the Nasal Airways Using a Facile Fluorescent-Imaging Method.

IF 2.2 4区 医学 Q3 RESPIRATORY SYSTEM
William Hunter, Kiao Inthavong, Sara Vahaji, Svetlana Stevanovic, David Morton
{"title":"Evaluating Powder Deposition in the Nasal Airways Using a Facile Fluorescent-Imaging Method.","authors":"William Hunter, Kiao Inthavong, Sara Vahaji, Svetlana Stevanovic, David Morton","doi":"10.1177/19412711261477975","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background:</i> Intranasal drug delivery is a critical route for both systemic and targeted therapies, particularly for drugs intended to reach the central nervous system via the olfactory region. However, current aqueous nasal sprays have limited penetration beyond the anterior nasal airway, reducing their efficacy for nose-to-brain drug delivery. Nasal powder insufflators offer a promising alternative, as they allow higher drug payloads, typically up to 50 mg. The narrower spray cone angle of some powder insufflators has the potential for improved drug penetration, making them more suitable to deliver drugs higher and deeper into the nasal airways than is possible for aqueous nasal sprays. Despite this potential, existing methods for assessing powder deposition rely on complex and expensive imaging techniques such as gamma scintigraphy or MRI, limiting their accessibility for formulation and device optimization.<i>Methods:</i> This study presents a novel, cost-effective fluorescent imaging method to evaluate nasal powder deposition patterns using a transparent Koken nasal cast coated with synthetic mucus. Fluorescein-dyed spray-dried powders were delivered through a capsule-based nasal powder insufflator actuated by an air pulse, and deposition patterns were visualized under UV excitation. ImageJ analysis was used to quantify fluorescent intensity and distribution across five predefined nasal regions.<i>Results:</i> The results demonstrated that the powder delivery device successfully bypassed the anterior nasal airway and deposited a significant proportion of the dose in the olfactory region, achieving a mean posterior upper airway deposition of 51.7%, a substantial improvement over conventional aqueous sprays. The air pulse-actuated delivery mechanism also exhibited high repeatability, with a coefficient of variation of 14.9% in olfactory region deposition.<i>Conclusion:</i> By providing a simple, noninvasive alternative to radiolabeled imaging, this fluorescence-based approach enables rapid evaluation of nasal powder formulations and delivery devices. Hence, the approach described in this work could enable the nasal delivery device parameters, and powder formulation parameters to be optimized for nasal powder delivery devices. This could in turn allow drug delivery efficiency to different regions of the nose-particularly the upper nasal airways-to be optimized to suit different powder formulations, and different powder delivery devices.</p>","PeriodicalId":14940,"journal":{"name":"Journal of Aerosol Medicine and Pulmonary Drug Delivery","volume":" ","pages":"19412711261477975"},"PeriodicalIF":2.2000,"publicationDate":"2026-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Aerosol Medicine and Pulmonary Drug Delivery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/19412711261477975","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Intranasal drug delivery is a critical route for both systemic and targeted therapies, particularly for drugs intended to reach the central nervous system via the olfactory region. However, current aqueous nasal sprays have limited penetration beyond the anterior nasal airway, reducing their efficacy for nose-to-brain drug delivery. Nasal powder insufflators offer a promising alternative, as they allow higher drug payloads, typically up to 50 mg. The narrower spray cone angle of some powder insufflators has the potential for improved drug penetration, making them more suitable to deliver drugs higher and deeper into the nasal airways than is possible for aqueous nasal sprays. Despite this potential, existing methods for assessing powder deposition rely on complex and expensive imaging techniques such as gamma scintigraphy or MRI, limiting their accessibility for formulation and device optimization.Methods: This study presents a novel, cost-effective fluorescent imaging method to evaluate nasal powder deposition patterns using a transparent Koken nasal cast coated with synthetic mucus. Fluorescein-dyed spray-dried powders were delivered through a capsule-based nasal powder insufflator actuated by an air pulse, and deposition patterns were visualized under UV excitation. ImageJ analysis was used to quantify fluorescent intensity and distribution across five predefined nasal regions.Results: The results demonstrated that the powder delivery device successfully bypassed the anterior nasal airway and deposited a significant proportion of the dose in the olfactory region, achieving a mean posterior upper airway deposition of 51.7%, a substantial improvement over conventional aqueous sprays. The air pulse-actuated delivery mechanism also exhibited high repeatability, with a coefficient of variation of 14.9% in olfactory region deposition.Conclusion: By providing a simple, noninvasive alternative to radiolabeled imaging, this fluorescence-based approach enables rapid evaluation of nasal powder formulations and delivery devices. Hence, the approach described in this work could enable the nasal delivery device parameters, and powder formulation parameters to be optimized for nasal powder delivery devices. This could in turn allow drug delivery efficiency to different regions of the nose-particularly the upper nasal airways-to be optimized to suit different powder formulations, and different powder delivery devices.

应用快速荧光成像方法评价鼻气道内粉末沉积。
背景:鼻内给药是全身性和靶向性治疗的关键途径,特别是对于通过嗅觉区到达中枢神经系统的药物。然而,目前的含水鼻喷雾剂穿透鼻腔前导气管的能力有限,降低了其经鼻至脑给药的功效。鼻粉吸入器提供了一个很有前途的选择,因为它们允许更高的药物有效载荷,通常高达50毫克。一些粉末喷雾器的较窄的喷雾锥角具有改善药物渗透的潜力,使它们比水性鼻喷雾器更适合将药物输送到更高更深的鼻气道中。尽管有这种潜力,但现有的粉末沉积评估方法依赖于复杂而昂贵的成像技术,如伽马闪烁成像或MRI,限制了它们在配方和设备优化方面的可及性。方法:本研究提出了一种新颖的、具有成本效益的荧光成像方法,使用涂有合成粘液的透明Koken鼻铸模来评估鼻粉末沉积模式。荧光素染色的喷雾干燥粉末通过一个由空气脉冲驱动的胶囊型鼻腔粉末注入器输送,并在紫外线激发下观察沉积模式。ImageJ分析用于量化荧光强度和分布在五个预先定义的鼻腔区域。结果:结果表明,粉末递送装置成功绕过鼻前气道,并在嗅觉区沉积了相当大比例的剂量,实现了51.7%的平均后上呼吸道沉积,比传统的水性喷雾剂有了很大的提高。空气脉冲驱动的传递机制具有较高的重复性,嗅觉区沉积的变异系数为14.9%。结论:通过提供一种简单、无创的替代放射标记成像的方法,这种基于荧光的方法可以快速评估鼻粉配方和给药装置。因此,本工作所描述的方法可以优化鼻腔给药装置的参数,以及鼻腔给药装置的粉末配方参数。这反过来又可以使药物输送到鼻子的不同区域,特别是上鼻气道,以优化不同的粉末配方和不同的粉末输送装置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.70
自引率
2.90%
发文量
34
审稿时长
>12 weeks
期刊介绍: Journal of Aerosol Medicine and Pulmonary Drug Delivery is the only peer-reviewed journal delivering innovative, authoritative coverage of the health effects of inhaled aerosols and delivery of drugs through the pulmonary system. The Journal is a forum for leading experts, addressing novel topics such as aerosolized chemotherapy, aerosolized vaccines, methods to determine toxicities, and delivery of aerosolized drugs in the intubated patient. Journal of Aerosol Medicine and Pulmonary Drug Delivery coverage includes: Pulmonary drug delivery Airway reactivity and asthma treatment Inhalation of particles and gases in the respiratory tract Toxic effects of inhaled agents Aerosols as tools for studying basic physiologic phenomena.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书