{"title":"Shaping Performance of XP4 versus ProTaper Next in C-Shaped Canals: A Micro-CT Study of 3D-Printed Mandibular Second Molar Replicas.","authors":"Zaidao Xiong, Lu Wang, Wenyuan Zhou, Zhongyang Shan, Chao Liu, Yongchun Gu, Jia Li","doi":"10.1002/cre2.70434","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This micro-computed tomography (micro-CT) study aimed to evaluate the shaping ability of two nickel-titanium (NiTi) rotary systems-XP4 and ProTaper Next (PTN)-in 3D-printed replicas of C-shaped canals.</p><p><strong>Methods: </strong>Two extracted mandibular second molars with C-shaped root canals-one continuous (Melton's Category I) and one discontinuous (Melton's Category II/III)-were selected and replicated via 3D printing. Replica accuracy was validated by best‑fit alignment. Sixteen resin replicas per specimen were randomly assigned to PTN or XP4 instrumentation (n = 8 per group) following the manufacturers' protocols. Pre- and post-instrumentation micro-CT scans were performed. Three-dimensional registration and reconstruction enabled quantitative analysis of (1) volume/surface area changes and (2) unprepared canal surfaces.</p><p><strong>Results: </strong>The replicas demonstrated high fabrication fidelity. In continuous C-shaped canals, PTN removed significantly less resin (2.7 mm<sup>3</sup>, 7.4% of initial volume) than XP4 (4.3 mm<sup>3</sup>, 11.6%; p < 0.01). Conversely, in discontinuous C-shaped configurations, PTN exhibited greater removal (13.0 mm<sup>3</sup>, 23.1%) versus XP4 (8.9 mm<sup>3</sup>, 15.8%; p < 0.01). Unprepared canal surface in continuous C replicas was higher with PTN (42.0%) than XP4 (25.5%; p < 0.01), whereas no significant difference was observed in discontinuous C replicas (PTN: 32.0%, XP4: 31.6%; p > 0.05). Procedural complications were observed exclusively in discontinuous C-shaped canals, with PTN causing two cases of critical wall thinning and XP4 exhibiting two instrument separations.</p><p><strong>Conclusion: </strong>In continuous C-shaped canal replicas, XP4 showed superior shaping capability with significantly lower percentages of unprepared surface compared to PTN. In discontinuous C-shaped configurations, both systems achieved comparable unprepared surface areas, although they differed markedly in resin removal patterns and iatrogenic risks. These results indicate that the relative performance and safety profiles of NiTi systems may vary depending on specific C-shaped canal anatomy. Clinicians should consider canal configuration, curvature severity, and dentin thickness when selecting instruments for C-shaped canal instrumentation.</p>","PeriodicalId":10203,"journal":{"name":"Clinical and Experimental Dental Research","volume":"12 4","pages":"e70434"},"PeriodicalIF":2.4000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13472515/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/cre2.70434","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: This micro-computed tomography (micro-CT) study aimed to evaluate the shaping ability of two nickel-titanium (NiTi) rotary systems-XP4 and ProTaper Next (PTN)-in 3D-printed replicas of C-shaped canals.

Methods: Two extracted mandibular second molars with C-shaped root canals-one continuous (Melton's Category I) and one discontinuous (Melton's Category II/III)-were selected and replicated via 3D printing. Replica accuracy was validated by best‑fit alignment. Sixteen resin replicas per specimen were randomly assigned to PTN or XP4 instrumentation (n = 8 per group) following the manufacturers' protocols. Pre- and post-instrumentation micro-CT scans were performed. Three-dimensional registration and reconstruction enabled quantitative analysis of (1) volume/surface area changes and (2) unprepared canal surfaces.

Results: The replicas demonstrated high fabrication fidelity. In continuous C-shaped canals, PTN removed significantly less resin (2.7 mm3, 7.4% of initial volume) than XP4 (4.3 mm3, 11.6%; p < 0.01). Conversely, in discontinuous C-shaped configurations, PTN exhibited greater removal (13.0 mm3, 23.1%) versus XP4 (8.9 mm3, 15.8%; p < 0.01). Unprepared canal surface in continuous C replicas was higher with PTN (42.0%) than XP4 (25.5%; p < 0.01), whereas no significant difference was observed in discontinuous C replicas (PTN: 32.0%, XP4: 31.6%; p > 0.05). Procedural complications were observed exclusively in discontinuous C-shaped canals, with PTN causing two cases of critical wall thinning and XP4 exhibiting two instrument separations.

Conclusion: In continuous C-shaped canal replicas, XP4 showed superior shaping capability with significantly lower percentages of unprepared surface compared to PTN. In discontinuous C-shaped configurations, both systems achieved comparable unprepared surface areas, although they differed markedly in resin removal patterns and iatrogenic risks. These results indicate that the relative performance and safety profiles of NiTi systems may vary depending on specific C-shaped canal anatomy. Clinicians should consider canal configuration, curvature severity, and dentin thickness when selecting instruments for C-shaped canal instrumentation.

XP4与ProTaper Next在c形牙管中的整形性能:3d打印下颌第二磨牙复制品的微ct研究
本微计算机断层扫描(micro-CT)研究旨在评估两种镍钛(NiTi)旋转系统- xp4和ProTaper Next (PTN)-在3d打印c形管复制品中的成形能力。方法:选择2颗带c型根管的下颌第二磨牙,1颗连续根管(Melton’s Category I), 1颗不连续根管(Melton’s Category II/III),采用3D打印复制。通过最佳拟合对齐验证了副本的准确性。按照制造商的方案,每个标本16个树脂复制品随机分配到PTN或XP4仪器(每组n = 8)。进行仪器前和仪器后的微ct扫描。三维配准和重建可以定量分析(1)体积/表面积变化和(2)未准备的运河表面。结果:该复制品具有较高的制作保真度。在连续的c形管中,PTN去除的树脂明显少于XP4 (4.3 mm3, 11.6%; p 3, 23.1%)和XP4 (8.9 mm3, 15.8%, p 0.05)。手术并发症仅在不连续的c形管中观察到,PTN导致2例临界管壁变薄,XP4出现2例器械分离。结论:与PTN相比,XP4在连续的c形管复制中表现出更强的塑形能力,且未准备表面的百分比显著降低。在不连续的c形配置中,两种系统都获得了相当的未准备表面积,尽管它们在树脂去除模式和医源性风险方面存在明显差异。这些结果表明,NiTi系统的相对性能和安全性可能取决于特定的c形管解剖结构。临床医生在选择c形根管预备器械时应考虑根管结构、弯曲程度和牙本质厚度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical and Experimental Dental Research
Clinical and Experimental Dental Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
5.60%
发文量
165
审稿时长
26 weeks
期刊介绍: Clinical and Experimental Dental Research aims to provide open access peer-reviewed publications of high scientific quality representing original clinical, diagnostic or experimental work within all disciplines and fields of oral medicine and dentistry. The scope of Clinical and Experimental Dental Research comprises original research material on the anatomy, physiology and pathology of oro-facial, oro-pharyngeal and maxillofacial tissues, and functions and dysfunctions within the stomatognathic system, and the epidemiology, aetiology, prevention, diagnosis, prognosis and therapy of diseases and conditions that have an effect on the homeostasis of the mouth, jaws, and closely associated structures, as well as the healing and regeneration and the clinical aspects of replacement of hard and soft tissues with biomaterials, and the rehabilitation of stomatognathic functions. Studies that bring new knowledge on how to advance health on the individual or public health levels, including interactions between oral and general health and ill-health are welcome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书