Stapedius reflex measurements in open sound-field in children using MED-EL cochlear implant systems.

IF 2 3区 医学 Q2 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
Rajdeep Kar, Palani Saravanan
{"title":"Stapedius reflex measurements in open sound-field in children using MED-EL cochlear implant systems.","authors":"Rajdeep Kar, Palani Saravanan","doi":"10.1080/14992027.2026.2715824","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The study compared stapedius reflex thresholds during presentation of acoustic stimuli in an open sound field (sf-SRT) in paediatric cochlear implant (CI) users with the MED-EL system and children with bilateral normal hearing sensitivity.</p><p><strong>Design: </strong>The sf-SRT was measured using open-sound-field acoustic stimulation with narrow-band noise (NBN) centred at 0.5, 1, 2, and 4 kHz, and broad-band noise (BBN). The sf-SRTs were measured twice in two different sessions.</p><p><strong>Study sample: </strong>Nineteen unilateral paediatric CI users and twenty children with bilateral normal hearing sensitivity, with an age range from 3 to 12 years.</p><p><strong>Results: </strong>The sf-SRT levels ranged from 65 to 103 dB HL and 70 to 90 dB HL across stimulus types in the CI and normal-hearing groups, respectively. Mann-Whitney U test revealed that the CI group had significantly higher sf-SRT levels for 2 kHz NBN than the normal-hearing group. In the CI group, repeated-measures ANOVA revealed significantly higher sf-SRT levels for NBN centred at 2 kHz than for 0.5 kHz and BBN. The sf-SRT measurements were reported to be reliable in the CI group.</p><p><strong>Conclusion: </strong>High test-retest reliability was demonstrated, supporting the use of sf-SRT measurements to confirm upper stimulation levels in paediatric CI users.</p>","PeriodicalId":13759,"journal":{"name":"International Journal of Audiology","volume":" ","pages":"1-13"},"PeriodicalIF":2.0000,"publicationDate":"2026-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Audiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/14992027.2026.2715824","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The study compared stapedius reflex thresholds during presentation of acoustic stimuli in an open sound field (sf-SRT) in paediatric cochlear implant (CI) users with the MED-EL system and children with bilateral normal hearing sensitivity.

Design: The sf-SRT was measured using open-sound-field acoustic stimulation with narrow-band noise (NBN) centred at 0.5, 1, 2, and 4 kHz, and broad-band noise (BBN). The sf-SRTs were measured twice in two different sessions.

Study sample: Nineteen unilateral paediatric CI users and twenty children with bilateral normal hearing sensitivity, with an age range from 3 to 12 years.

Results: The sf-SRT levels ranged from 65 to 103 dB HL and 70 to 90 dB HL across stimulus types in the CI and normal-hearing groups, respectively. Mann-Whitney U test revealed that the CI group had significantly higher sf-SRT levels for 2 kHz NBN than the normal-hearing group. In the CI group, repeated-measures ANOVA revealed significantly higher sf-SRT levels for NBN centred at 2 kHz than for 0.5 kHz and BBN. The sf-SRT measurements were reported to be reliable in the CI group.

Conclusion: High test-retest reliability was demonstrated, supporting the use of sf-SRT measurements to confirm upper stimulation levels in paediatric CI users.

使用MED-EL人工耳蜗系统对儿童开放声场的镫骨反射测量。
目的:本研究比较了使用MED-EL系统的儿童人工耳蜗使用者和双侧听力正常的儿童在开放声场(sf-SRT)声刺激时的镫骨反射阈值。设计:采用开放声场声刺激测量sf-SRT,其中以0.5、1、2和4 kHz为中心的窄带噪声(NBN)和宽带噪声(BBN)。sf- srt在两个不同的阶段测量了两次。研究样本:19名单侧儿童CI使用者和20名双侧听力正常的儿童,年龄范围从3岁到12岁。结果:在CI组和正常听力组中,不同刺激类型的sf-SRT水平分别为65 ~ 103 dB HL和70 ~ 90 dB HL。Mann-Whitney U检验显示,CI组在2 kHz NBN时的sf-SRT水平显著高于正常听力组。在CI组中,重复测量方差分析显示,以2 kHz为中心的NBN的sf-SRT水平显著高于0.5 kHz和BBN。据报道,在CI组中,sf-SRT测量是可靠的。结论:高测试-重测可靠性被证明,支持使用sf-SRT测量来确认儿科CI使用者的高刺激水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Audiology
International Journal of Audiology 医学-耳鼻喉科学
CiteScore
4.90
自引率
14.80%
发文量
133
审稿时长
4-8 weeks
期刊介绍: International Journal of Audiology is committed to furthering development of a scientifically robust evidence base for audiology. The journal is published by the British Society of Audiology, the International Society of Audiology and the Nordic Audiological Society.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书