Multi-Channel Integrated Electronics Design for Bolometer Diagnostic Based on Metal Foil Detector in Tokamak Device

IF 0.4 4区 工程技术 Q4 ENGINEERING, MULTIDISCIPLINARY
Zhong-Hui Wang, Hong-Rui Cao, Shi-Xing Liu, Yan-Min Duan, Jin-Long Zhao
{"title":"Multi-Channel Integrated Electronics Design for Bolometer Diagnostic Based on Metal Foil Detector in Tokamak Device","authors":"Zhong-Hui Wang,&nbsp;Hong-Rui Cao,&nbsp;Shi-Xing Liu,&nbsp;Yan-Min Duan,&nbsp;Jin-Long Zhao","doi":"10.1134/S0020441226700569","DOIUrl":null,"url":null,"abstract":"<p>In magnetic confinement nuclear fusion research, precise measurement of plasma radiative power is fundamental to understanding energy balance, physics of transportation, and ensuring safe device operation. This paper presentsmulti-channel integrated electronics, featuring an FPGA as the main controller and GbE communication, designed for metal foil detector with both positive and negative response channels for bolometer diagnostic. In this electronics design, compared to the single-channel electronics prototype developed recently, the phase shift circuit is optimized, DDS is adopted to generate carrier reference signal, and dynamic range compensation circuitry is incorporated. Within the constrained chassis, it integrates eight channels, significantly enhancing channel integration compared to the original BOLOMETER electronics on EAST. Performance testing in the electronics laboratory verified that all channels of this multi-channel integrated electronics exhibit consistent carrier excitation frequencies, with thethe maximum relative amplitude error of 0.48%. The linear correlation coefficient <i>R</i>-square between the electronics output and the detector output is 0.99997. At channel gain of 1000, the single-channel electronics noise is ±1.25 mV. Radiation response experiments on EAST demonstrate that the output signal trend of this electronics matched the time-varying trend of the plasma current and is similar to the output signal trend of the original BOLOMETER electronics, confirming the correctness of this electronics.</p>","PeriodicalId":587,"journal":{"name":"Instruments and Experimental Techniques","volume":"69 3","pages":"486 - 495"},"PeriodicalIF":0.4000,"publicationDate":"2026-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instruments and Experimental Techniques","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1134/S0020441226700569","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

In magnetic confinement nuclear fusion research, precise measurement of plasma radiative power is fundamental to understanding energy balance, physics of transportation, and ensuring safe device operation. This paper presentsmulti-channel integrated electronics, featuring an FPGA as the main controller and GbE communication, designed for metal foil detector with both positive and negative response channels for bolometer diagnostic. In this electronics design, compared to the single-channel electronics prototype developed recently, the phase shift circuit is optimized, DDS is adopted to generate carrier reference signal, and dynamic range compensation circuitry is incorporated. Within the constrained chassis, it integrates eight channels, significantly enhancing channel integration compared to the original BOLOMETER electronics on EAST. Performance testing in the electronics laboratory verified that all channels of this multi-channel integrated electronics exhibit consistent carrier excitation frequencies, with thethe maximum relative amplitude error of 0.48%. The linear correlation coefficient R-square between the electronics output and the detector output is 0.99997. At channel gain of 1000, the single-channel electronics noise is ±1.25 mV. Radiation response experiments on EAST demonstrate that the output signal trend of this electronics matched the time-varying trend of the plasma current and is similar to the output signal trend of the original BOLOMETER electronics, confirming the correctness of this electronics.

基于托卡马克金属箔探测器的辐射热计诊断多通道集成电子设计
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Instruments and Experimental Techniques
Instruments and Experimental Techniques 工程技术-工程:综合
CiteScore
1.20
自引率
33.30%
发文量
113
审稿时长
4-8 weeks
期刊介绍: Instruments and Experimental Techniques is an international peer reviewed journal that publishes reviews describing advanced methods for physical measurements and techniques and original articles that present techniques for physical measurements, principles of operation, design, methods of application, and analysis of the operation of physical instruments used in all fields of experimental physics and when conducting measurements using physical methods and instruments in astronomy, natural sciences, chemistry, biology, medicine, and ecology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书