Eyal Ben-Assa MD, Bruce A. Samuels MD, Ehtisham Mahmud MD, Carlos Cafri MD, Ariel Roguin MD, PhD, Yair Feld MD, Eli Lev MD, MHA, Emanuel Harari MD, Tali Ben-Yehuda MD, Hector M. Garcia-Garcia MD, PhD, Gregg W. Stone MD
{"title":"Artificial Intelligence-Derived Fractional Flow Reserve in Routine Clinical Practice: An International Multicenter Retrospective Study","authors":"Eyal Ben-Assa MD, Bruce A. Samuels MD, Ehtisham Mahmud MD, Carlos Cafri MD, Ariel Roguin MD, PhD, Yair Feld MD, Eli Lev MD, MHA, Emanuel Harari MD, Tali Ben-Yehuda MD, Hector M. Garcia-Garcia MD, PhD, Gregg W. Stone MD","doi":"10.1016/j.jscai.2026.105451","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Artificial intelligence-based fractional flow reserve (AI-FFR) incorporates a machine learning-based algorithm to derive FFR directly from angiography. Its accuracy compared with invasive FFR has not been assessed.</div></div><div><h3>Methods</h3><div>AI-FFR was compared with wire-based FFR in patients with a single intermediate lesion (diameter stenosis ≥40% to <70%) at 5 centers in the United States and Israel. AI-FFR assessments were performed by core laboratory analysts blinded to invasive FFR results. Diagnostic performance metrics were calculated using an FFR threshold of ≤0.80.</div></div><div><h3>Results</h3><div>A total of 504 vessels from 496 patients were analyzed. AI-FFR computation time was 36.1 ± 7.7 seconds. Lesion detection was fully automatic in 371 of 504 (73.6%) vessels, whereas semiautomated analysis with manual marking was performed in 133 of 504 (26.4%) vessels. Mean wire-based FFR was 0.85 ± 0.07 and mean AI-FFR was 0.85 ± 0.08 (mean difference, 0.00 ± 0.08; 95% CI, −0.15 to 0.15; <em>P</em> = .41). AI-FFR showed a sensitivity of 90.2%, specificity of 94.9%, positive predictive value of 83.5%, negative predictive value of 97.1%, and overall diagnostic accuracy of 93.8%. The area under the receiver operating characteristic curve (AUC) was 0.93 (95% CI, 0.89-0.96). Among 151 lesions with wire-based FFR values in the borderline “gray zone” (0.75-0.85), AI-FFR demonstrated a diagnostic accuracy of 91.4% and an AUC of 0.91 (95% CI, 0.86-0.96). AI-FFR demonstrated high diagnostic accuracy across vessel types and lesion locations in men and women and between the US and Israeli cohorts.</div></div><div><h3>Conclusions</h3><div>AI-FFR, an automated, machine learning-based tool, demonstrated high diagnostic accuracy compared with wire-based FFR. Its speed, simplicity, and independence from complex procedural steps may facilitate broader adoption during coronary angiography.</div></div>","PeriodicalId":73990,"journal":{"name":"Journal of the Society for Cardiovascular Angiography & Interventions","volume":"5 8","pages":"Article 105451"},"PeriodicalIF":0.0000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Society for Cardiovascular Angiography & Interventions","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772930326011981","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Artificial intelligence-based fractional flow reserve (AI-FFR) incorporates a machine learning-based algorithm to derive FFR directly from angiography. Its accuracy compared with invasive FFR has not been assessed.
Methods
AI-FFR was compared with wire-based FFR in patients with a single intermediate lesion (diameter stenosis ≥40% to <70%) at 5 centers in the United States and Israel. AI-FFR assessments were performed by core laboratory analysts blinded to invasive FFR results. Diagnostic performance metrics were calculated using an FFR threshold of ≤0.80.
Results
A total of 504 vessels from 496 patients were analyzed. AI-FFR computation time was 36.1 ± 7.7 seconds. Lesion detection was fully automatic in 371 of 504 (73.6%) vessels, whereas semiautomated analysis with manual marking was performed in 133 of 504 (26.4%) vessels. Mean wire-based FFR was 0.85 ± 0.07 and mean AI-FFR was 0.85 ± 0.08 (mean difference, 0.00 ± 0.08; 95% CI, −0.15 to 0.15; P = .41). AI-FFR showed a sensitivity of 90.2%, specificity of 94.9%, positive predictive value of 83.5%, negative predictive value of 97.1%, and overall diagnostic accuracy of 93.8%. The area under the receiver operating characteristic curve (AUC) was 0.93 (95% CI, 0.89-0.96). Among 151 lesions with wire-based FFR values in the borderline “gray zone” (0.75-0.85), AI-FFR demonstrated a diagnostic accuracy of 91.4% and an AUC of 0.91 (95% CI, 0.86-0.96). AI-FFR demonstrated high diagnostic accuracy across vessel types and lesion locations in men and women and between the US and Israeli cohorts.
Conclusions
AI-FFR, an automated, machine learning-based tool, demonstrated high diagnostic accuracy compared with wire-based FFR. Its speed, simplicity, and independence from complex procedural steps may facilitate broader adoption during coronary angiography.