A Comparative Analysis of Virtual 2D VMAT-Based SFRT and 3D Lattice Radiotherapy: Evaluation of Dosimetric and Therapeutic Outcomes.

Q3 Medicine
Elnaz Balvasi, Farshid Mahmoudi, Parastoo Farina, Ali Ameri, Fatemeh Jafari, Ghazale Geraily
{"title":"A Comparative Analysis of Virtual 2D VMAT-Based SFRT and 3D Lattice Radiotherapy: Evaluation of Dosimetric and Therapeutic Outcomes.","authors":"Elnaz Balvasi, Farshid Mahmoudi, Parastoo Farina, Ali Ameri, Fatemeh Jafari, Ghazale Geraily","doi":"10.31661/jbpe.v0i0.2410-1835","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Spatially Fractionated Radiotherapy (SFRT) can be implemented using Volumetric-Modulated Arc Therapy (VMAT) in either two-dimensional (2D) or three-dimensional (3D) configurations.</p><p><strong>Objective: </strong>This study aimed to compare the dosimetric and clinical outcomes of two VMAT-based SFRT techniques for large lung tumors.</p><p><strong>Material and methods: </strong>In this experimental study, SFRT plans were designed for each patient using cylindrical and spherical grid targets. Single-fraction prescription doses of 15 and 20 Gy were delivered to the grid target isocenters using 6 MV Flattening-filter-free (FFF) photon beams.</p><p><strong>Results: </strong>The 2D SFRT plan demonstrated higher Gross Tumor Volume (GTV) mean dose, GTV Equivalent Uniform Dose (EUD), and Valley-to-peak Dose ratio (VPDR) compared to the 3D lattice plan. However, the 3D Lattice Radiotherapy (3D-LRT) technique provided a better therapeutic ratio and more uniform valley-peak dose distribution. Both plans demonstrated therapeutic ratios greater than one with minimal Normal Tissue Complication Probability (NTCP).</p><p><strong>Conclusion: </strong>Both 2D and 3D lattice VMAT-based SFRT techniques effectively delivered high radiation doses with steep dose gradients within the GTV, minimizing normal tissue exposure and reducing the risk of complications.</p>","PeriodicalId":38035,"journal":{"name":"Journal of Biomedical Physics and Engineering","volume":"16 4","pages":"285-296"},"PeriodicalIF":0.0000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13457497/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31661/jbpe.v0i0.2410-1835","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Spatially Fractionated Radiotherapy (SFRT) can be implemented using Volumetric-Modulated Arc Therapy (VMAT) in either two-dimensional (2D) or three-dimensional (3D) configurations.

Objective: This study aimed to compare the dosimetric and clinical outcomes of two VMAT-based SFRT techniques for large lung tumors.

Material and methods: In this experimental study, SFRT plans were designed for each patient using cylindrical and spherical grid targets. Single-fraction prescription doses of 15 and 20 Gy were delivered to the grid target isocenters using 6 MV Flattening-filter-free (FFF) photon beams.

Results: The 2D SFRT plan demonstrated higher Gross Tumor Volume (GTV) mean dose, GTV Equivalent Uniform Dose (EUD), and Valley-to-peak Dose ratio (VPDR) compared to the 3D lattice plan. However, the 3D Lattice Radiotherapy (3D-LRT) technique provided a better therapeutic ratio and more uniform valley-peak dose distribution. Both plans demonstrated therapeutic ratios greater than one with minimal Normal Tissue Complication Probability (NTCP).

Conclusion: Both 2D and 3D lattice VMAT-based SFRT techniques effectively delivered high radiation doses with steep dose gradients within the GTV, minimizing normal tissue exposure and reducing the risk of complications.

基于虚拟二维vmat的SFRT和三维点阵放疗的比较分析:剂量学和治疗结果的评估。
背景:空间分割放疗(SFRT)可以在二维(2D)或三维(3D)配置中使用体积调制电弧治疗(VMAT)来实现。目的:本研究旨在比较两种基于vmat的SFRT技术治疗大肺肿瘤的剂量学和临床结果。材料与方法:在本实验研究中,采用圆柱形和球形网格靶为每位患者设计了SFRT计划。使用6 MV无平坦滤波(FFF)光子束将15和20 Gy的单组分处方剂量传递到网格目标等中心。结果:与三维点阵方案相比,二维SFRT方案显示出更高的总肿瘤体积(GTV)平均剂量、GTV等效均匀剂量(EUD)和谷峰剂量比(VPDR)。而三维点阵放疗(3D- lrt)技术具有更好的治疗比和更均匀的谷峰剂量分布。两种方案的治疗率均大于正常组织并发症概率(NTCP)最小的方案。结论:基于二维和三维点阵vmat的SFRT技术均能有效地在GTV内提供高剂量和陡剂量梯度的辐射,最大限度地减少正常组织暴露,降低并发症的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Biomedical Physics and Engineering
Journal of Biomedical Physics and Engineering Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
2.90
自引率
0.00%
发文量
64
审稿时长
10 weeks
期刊介绍: The Journal of Biomedical Physics and Engineering (JBPE) is a bimonthly peer-reviewed English-language journal that publishes high-quality basic sciences and clinical research (experimental or theoretical) broadly concerned with the relationship of physics to medicine and engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书