{"title":"A Comparative Analysis of Virtual 2D VMAT-Based SFRT and 3D Lattice Radiotherapy: Evaluation of Dosimetric and Therapeutic Outcomes.","authors":"Elnaz Balvasi, Farshid Mahmoudi, Parastoo Farina, Ali Ameri, Fatemeh Jafari, Ghazale Geraily","doi":"10.31661/jbpe.v0i0.2410-1835","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Spatially Fractionated Radiotherapy (SFRT) can be implemented using Volumetric-Modulated Arc Therapy (VMAT) in either two-dimensional (2D) or three-dimensional (3D) configurations.</p><p><strong>Objective: </strong>This study aimed to compare the dosimetric and clinical outcomes of two VMAT-based SFRT techniques for large lung tumors.</p><p><strong>Material and methods: </strong>In this experimental study, SFRT plans were designed for each patient using cylindrical and spherical grid targets. Single-fraction prescription doses of 15 and 20 Gy were delivered to the grid target isocenters using 6 MV Flattening-filter-free (FFF) photon beams.</p><p><strong>Results: </strong>The 2D SFRT plan demonstrated higher Gross Tumor Volume (GTV) mean dose, GTV Equivalent Uniform Dose (EUD), and Valley-to-peak Dose ratio (VPDR) compared to the 3D lattice plan. However, the 3D Lattice Radiotherapy (3D-LRT) technique provided a better therapeutic ratio and more uniform valley-peak dose distribution. Both plans demonstrated therapeutic ratios greater than one with minimal Normal Tissue Complication Probability (NTCP).</p><p><strong>Conclusion: </strong>Both 2D and 3D lattice VMAT-based SFRT techniques effectively delivered high radiation doses with steep dose gradients within the GTV, minimizing normal tissue exposure and reducing the risk of complications.</p>","PeriodicalId":38035,"journal":{"name":"Journal of Biomedical Physics and Engineering","volume":"16 4","pages":"285-296"},"PeriodicalIF":0.0000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13457497/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31661/jbpe.v0i0.2410-1835","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Spatially Fractionated Radiotherapy (SFRT) can be implemented using Volumetric-Modulated Arc Therapy (VMAT) in either two-dimensional (2D) or three-dimensional (3D) configurations.
Objective: This study aimed to compare the dosimetric and clinical outcomes of two VMAT-based SFRT techniques for large lung tumors.
Material and methods: In this experimental study, SFRT plans were designed for each patient using cylindrical and spherical grid targets. Single-fraction prescription doses of 15 and 20 Gy were delivered to the grid target isocenters using 6 MV Flattening-filter-free (FFF) photon beams.
Results: The 2D SFRT plan demonstrated higher Gross Tumor Volume (GTV) mean dose, GTV Equivalent Uniform Dose (EUD), and Valley-to-peak Dose ratio (VPDR) compared to the 3D lattice plan. However, the 3D Lattice Radiotherapy (3D-LRT) technique provided a better therapeutic ratio and more uniform valley-peak dose distribution. Both plans demonstrated therapeutic ratios greater than one with minimal Normal Tissue Complication Probability (NTCP).
Conclusion: Both 2D and 3D lattice VMAT-based SFRT techniques effectively delivered high radiation doses with steep dose gradients within the GTV, minimizing normal tissue exposure and reducing the risk of complications.
期刊介绍:
The Journal of Biomedical Physics and Engineering (JBPE) is a bimonthly peer-reviewed English-language journal that publishes high-quality basic sciences and clinical research (experimental or theoretical) broadly concerned with the relationship of physics to medicine and engineering.