Wear Rate, Particle Morphology, and Biocompatibility of Polyether-Ether-Ketone Femoral Heads Against Highly Cross-Linked Polyethylene Acetabular Cups in Hip Prosthetic Couples
Fei Hu, Xinyue Zhang, Xiaobo Wu, Zhuocheng Lyu, Xu Zheng, Linjun Yang, Zikai Hua, Dekun Zhang, You Wang
{"title":"Wear Rate, Particle Morphology, and Biocompatibility of Polyether-Ether-Ketone Femoral Heads Against Highly Cross-Linked Polyethylene Acetabular Cups in Hip Prosthetic Couples","authors":"Fei Hu, Xinyue Zhang, Xiaobo Wu, Zhuocheng Lyu, Xu Zheng, Linjun Yang, Zikai Hua, Dekun Zhang, You Wang","doi":"10.1002/jbm.b.70139","DOIUrl":null,"url":null,"abstract":"<p>Biological reactions to wear particles from artificial joint prostheses can lead to osteolysis, ultimately resulting in aseptic loosening and implant failure, which affect the longevity of the prosthesis and the patient's quality of life. Polyether-ether-ketone (PEEK) has emerged as a key area of research in orthopedic implant materials due to its excellent wear resistance and biomechanical compatibility with human bone tissue. In this study, we conducted a 10-million-cycle simulator wear test on hip artificial joints with polyetheretherketone-on-highly cross-linked polyethylene (PEEK-on-HCLPE) bearing couplings for the first time. The results indicated the total wear loss of the highly cross-linked polyethylene (HCLPE) liners was 34.03 ± 3.2 mg (~2.96 mg/MC or 3.18 mm<sup>3</sup>/MC after linear fitting). The physicochemical properties of the mixed particles indicated a predominant particle size distribution ranging from 0.1 to 0.5 μm. Pure PEEK or HCLPE particles with the similar size range (maximum size: 0.5 μm) were generated by an EXAKT grinding system, followed by vacuum filtration with precision pore—size membranes for the biocompatibility experiments. In vitro immunological assays showed that 0.1 to 0.5 μm PEEK particles may induce a relatively weaker immune inflammatory effect than 0.1 to 0.5 μm HCLPE particles. In conclusion, the PEEK-on-HCLPE bearing couple has been demonstrated to have acceptable biosafety and a wear rate suitable for use as a potential hip replacement implant.</p>","PeriodicalId":15269,"journal":{"name":"Journal of biomedical materials research. Part B, Applied biomaterials","volume":"114 8","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2026-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jbm.b.70139","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical materials research. Part B, Applied biomaterials","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jbm.b.70139","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Biological reactions to wear particles from artificial joint prostheses can lead to osteolysis, ultimately resulting in aseptic loosening and implant failure, which affect the longevity of the prosthesis and the patient's quality of life. Polyether-ether-ketone (PEEK) has emerged as a key area of research in orthopedic implant materials due to its excellent wear resistance and biomechanical compatibility with human bone tissue. In this study, we conducted a 10-million-cycle simulator wear test on hip artificial joints with polyetheretherketone-on-highly cross-linked polyethylene (PEEK-on-HCLPE) bearing couplings for the first time. The results indicated the total wear loss of the highly cross-linked polyethylene (HCLPE) liners was 34.03 ± 3.2 mg (~2.96 mg/MC or 3.18 mm3/MC after linear fitting). The physicochemical properties of the mixed particles indicated a predominant particle size distribution ranging from 0.1 to 0.5 μm. Pure PEEK or HCLPE particles with the similar size range (maximum size: 0.5 μm) were generated by an EXAKT grinding system, followed by vacuum filtration with precision pore—size membranes for the biocompatibility experiments. In vitro immunological assays showed that 0.1 to 0.5 μm PEEK particles may induce a relatively weaker immune inflammatory effect than 0.1 to 0.5 μm HCLPE particles. In conclusion, the PEEK-on-HCLPE bearing couple has been demonstrated to have acceptable biosafety and a wear rate suitable for use as a potential hip replacement implant.
期刊介绍:
Journal of Biomedical Materials Research – Part B: Applied Biomaterials is a highly interdisciplinary peer-reviewed journal serving the needs of biomaterials professionals who design, develop, produce and apply biomaterials and medical devices. It has the common focus of biomaterials applied to the human body and covers all disciplines where medical devices are used. Papers are published on biomaterials related to medical device development and manufacture, degradation in the body, nano- and biomimetic- biomaterials interactions, mechanics of biomaterials, implant retrieval and analysis, tissue-biomaterial surface interactions, wound healing, infection, drug delivery, standards and regulation of devices, animal and pre-clinical studies of biomaterials and medical devices, and tissue-biopolymer-material combination products. Manuscripts are published in one of six formats:
• original research reports
• short research and development reports
• scientific reviews
• current concepts articles
• special reports
• editorials
Journal of Biomedical Materials Research – Part B: Applied Biomaterials is an official journal of the Society for Biomaterials, Japanese Society for Biomaterials, the Australasian Society for Biomaterials, and the Korean Society for Biomaterials. Manuscripts from all countries are invited but must be in English. Authors are not required to be members of the affiliated Societies, but members of these societies are encouraged to submit their work to the journal for consideration.