A Method for Measuring Intraocular Pressure in Wild-Type Zebrafish Using Rebound Tonometry: Characterization, Sex Differences, and Long-Term Repeatability.

IF 1.2
Hsin-Lin Cheng, Pei-Hsuan Chou, Yung-Chang Yen, Jiann-Jou Yang
{"title":"A Method for Measuring Intraocular Pressure in Wild-Type Zebrafish Using Rebound Tonometry: Characterization, Sex Differences, and Long-Term Repeatability.","authors":"Hsin-Lin Cheng, Pei-Hsuan Chou, Yung-Chang Yen, Jiann-Jou Yang","doi":"10.1177/15458547261477301","DOIUrl":null,"url":null,"abstract":"<p><p>Intraocular pressure (IOP) monitoring is a critical aspect of diagnosis, and management of ocular diseases. Therefore, a tractable vertebrate model capable of reliable IOP characterization is highly desirable. The present study aims to perform a preliminary investigation of a handheld rebound tonometer to stably measure IOP and further characterize baseline IOP values in the zebrafish model. The IOP in both eyes (oculus dexter, OD, and oculus sinister, OS) of wild-type zebrafish was measured using the iCare PRO rebound tonometer at the same time points on testing days for 18 months. The long-term IOP values of male zebrafish (3-21 months) were range from 21.96 ± 0.99 to 23.39 ± 0.32 mm Hg (OD) and 22.10 ± 0.93 to 23.38 ± 0.26 mm Hg (OS), while insignificant difference was noted among testing days (<i>p</i> > 0.05). Similarly, insignificant difference was observed in female zebrafish with IOP values range from 22.10 ± 1.12 to 23.19 ± 0.72 mm Hg (OD) and 22.30 ± 1.00 to 23.15 ± 0.36 mm Hg (OS) (<i>p</i> > 0.05). A comprehensive evaluation of IOP profiles confirmed no significant differences based on gender, time point, and between eyes. These findings indicated that our iCare tonometer-based experimental methods provide high measurement and time-point consistency, confirming their long-term reproducibility and reliability in measuring IOP in the zebrafish.</p>","PeriodicalId":94273,"journal":{"name":"Zebrafish","volume":" ","pages":"15458547261477301"},"PeriodicalIF":1.2000,"publicationDate":"2026-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zebrafish","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15458547261477301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Intraocular pressure (IOP) monitoring is a critical aspect of diagnosis, and management of ocular diseases. Therefore, a tractable vertebrate model capable of reliable IOP characterization is highly desirable. The present study aims to perform a preliminary investigation of a handheld rebound tonometer to stably measure IOP and further characterize baseline IOP values in the zebrafish model. The IOP in both eyes (oculus dexter, OD, and oculus sinister, OS) of wild-type zebrafish was measured using the iCare PRO rebound tonometer at the same time points on testing days for 18 months. The long-term IOP values of male zebrafish (3-21 months) were range from 21.96 ± 0.99 to 23.39 ± 0.32 mm Hg (OD) and 22.10 ± 0.93 to 23.38 ± 0.26 mm Hg (OS), while insignificant difference was noted among testing days (p > 0.05). Similarly, insignificant difference was observed in female zebrafish with IOP values range from 22.10 ± 1.12 to 23.19 ± 0.72 mm Hg (OD) and 22.30 ± 1.00 to 23.15 ± 0.36 mm Hg (OS) (p > 0.05). A comprehensive evaluation of IOP profiles confirmed no significant differences based on gender, time point, and between eyes. These findings indicated that our iCare tonometer-based experimental methods provide high measurement and time-point consistency, confirming their long-term reproducibility and reliability in measuring IOP in the zebrafish.

一种使用回弹眼压计测量野生型斑马鱼眼压的方法:特征、性别差异和长期可重复性。
眼压监测是眼部疾病诊断和治疗的重要方面。因此,一个易于操作的脊椎动物模型能够可靠的IOP表征是非常需要的。本研究旨在对手持式回弹眼压计进行初步研究,以稳定测量眼压,并进一步表征斑马鱼模型的基线眼压值。使用iCare PRO回弹眼压仪在测试日的同一时间点测量野生型斑马鱼双眼(右眼OD和右眼OS)的IOP。雄性斑马鱼(3 ~ 21月龄)的长期IOP值分别为21.96±0.99 ~ 23.39±0.32 mm Hg (OD)和22.10±0.93 ~ 23.38±0.26 mm Hg (OS),各组间差异无统计学意义(p < 0.05)。同样,雌性斑马鱼的IOP值在22.10±1.12 ~ 23.19±0.72 mm Hg (OD)和22.30±1.00 ~ 23.15±0.36 mm Hg (OS)之间差异不显著(p < 0.05)。综合评估IOP资料证实,基于性别、时间点和眼睛之间没有显著差异。这些结果表明,基于iCare眼压计的实验方法具有较高的测量一致性和时间点一致性,证实了其测量斑马鱼眼压的长期重复性和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书