Diagnostic performance and short-interval reproducibility of multimodal large language models in differentiating cholesteatoma from chronic otitis media using key-image temporal bone high-resolution computed tomography.

IF 2.7 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Buket Yağcı, Sergen Palaz, Erdem Atalay Çetinkaya, Utku Şenol
{"title":"Diagnostic performance and short-interval reproducibility of multimodal large language models in differentiating cholesteatoma from chronic otitis media using key-image temporal bone high-resolution computed tomography.","authors":"Buket Yağcı, Sergen Palaz, Erdem Atalay Çetinkaya, Utku Şenol","doi":"10.4274/dir.2026.264082","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to assess whether multimodal large language models (LLMs) can distinguish cholesteatoma from non-cholesteatomatous chronic otitis media (COM) on representative key-image temporal bone high-resolution computed tomography (HRCT) and to evaluate the short-interval reproducibility of their outputs.</p><p><strong>Methods: </strong>This retrospective, single-center study (2019-2024) included 101 patients (48 with cholesteatoma, 53 with non-cholesteatomatous COM) who underwent surgical treatment. The reference standard was intraoperative diagnosis with histopathological confirmation for cholesteatoma and surgical documentation for COM. For each case, six anonymized representative HRCT images reflecting standard diagnostic criteria were selected by consensus between a 4<sup>th</sup>-year radiology resident and a board-certified head and neck radiologist, both unaware of the diagnosis. Subsequently, the same images were analyzed by the GPT-5 and Gemini 2.5 Pro LLMs through their official web interfaces, utilizing structured prompts and a zero-shot approach. These evaluations were conducted in two distinct sessions (S1 and S2) with a 1-week interval. The primary endpoint was accurate binary classification. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were calculated with 95% confidence intervals [(CIs); Wilson method] agreement with the reference standard and between sessions and models was assessed with the Cohen kappa (κ) coefficient; and differences in classification were assessed with the McNemar test.</p><p><strong>Results: </strong>The radiologist achieved an accuracy of 96.0% (95% CI: 90.3-98.4) with almost perfect agreement with the reference standard (κ: 0.921). In S1, GPT-5 and Gemini 2.5 Pro achieved accuracies of 43.6% and 49.5%, and in S2, 46.5% and 47.5%, respectively. Both models combined high sensitivity (83.3%-97.9%) with low specificity (1.9%-13.2%), and balanced accuracy ranged from 0.45 to 0.52. Between-session reproducibility was fair for GPT-5 (κ: 0.360) and moderate for Gemini 2.5 Pro (κ: 0.485), and inter-model agreement was slight at both sessions (κ: 0.035 at S1 and κ: 0.086 at S2). Accuracy did not differ significantly between the two models (<i>P</i> = 0.211).</p><p><strong>Conclusion: </strong>In this single-center study, GPT-5 and Gemini 2.5 Pro, in the versions evaluated, combined high sensitivity with low specificity and showed only fair-to-moderate between-session reproducibility and exhibited slight inter-model agreement on temporal bone key-image HRCT. These findings do not support their use as independent second readers, and broader generalization to other multimodal LLMs would require the evaluation of additional models.</p><p><strong>Clinical significance: </strong>The evaluated models lacked the spatial precision and consistency required for the accurate assessment of complex middle ear structures. This finding underscores the necessity for verification by a radiologist and continuous monitoring.</p>","PeriodicalId":11341,"journal":{"name":"Diagnostic and interventional radiology","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2026-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and interventional radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4274/dir.2026.264082","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aimed to assess whether multimodal large language models (LLMs) can distinguish cholesteatoma from non-cholesteatomatous chronic otitis media (COM) on representative key-image temporal bone high-resolution computed tomography (HRCT) and to evaluate the short-interval reproducibility of their outputs.

Methods: This retrospective, single-center study (2019-2024) included 101 patients (48 with cholesteatoma, 53 with non-cholesteatomatous COM) who underwent surgical treatment. The reference standard was intraoperative diagnosis with histopathological confirmation for cholesteatoma and surgical documentation for COM. For each case, six anonymized representative HRCT images reflecting standard diagnostic criteria were selected by consensus between a 4th-year radiology resident and a board-certified head and neck radiologist, both unaware of the diagnosis. Subsequently, the same images were analyzed by the GPT-5 and Gemini 2.5 Pro LLMs through their official web interfaces, utilizing structured prompts and a zero-shot approach. These evaluations were conducted in two distinct sessions (S1 and S2) with a 1-week interval. The primary endpoint was accurate binary classification. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were calculated with 95% confidence intervals [(CIs); Wilson method] agreement with the reference standard and between sessions and models was assessed with the Cohen kappa (κ) coefficient; and differences in classification were assessed with the McNemar test.

Results: The radiologist achieved an accuracy of 96.0% (95% CI: 90.3-98.4) with almost perfect agreement with the reference standard (κ: 0.921). In S1, GPT-5 and Gemini 2.5 Pro achieved accuracies of 43.6% and 49.5%, and in S2, 46.5% and 47.5%, respectively. Both models combined high sensitivity (83.3%-97.9%) with low specificity (1.9%-13.2%), and balanced accuracy ranged from 0.45 to 0.52. Between-session reproducibility was fair for GPT-5 (κ: 0.360) and moderate for Gemini 2.5 Pro (κ: 0.485), and inter-model agreement was slight at both sessions (κ: 0.035 at S1 and κ: 0.086 at S2). Accuracy did not differ significantly between the two models (P = 0.211).

Conclusion: In this single-center study, GPT-5 and Gemini 2.5 Pro, in the versions evaluated, combined high sensitivity with low specificity and showed only fair-to-moderate between-session reproducibility and exhibited slight inter-model agreement on temporal bone key-image HRCT. These findings do not support their use as independent second readers, and broader generalization to other multimodal LLMs would require the evaluation of additional models.

Clinical significance: The evaluated models lacked the spatial precision and consistency required for the accurate assessment of complex middle ear structures. This finding underscores the necessity for verification by a radiologist and continuous monitoring.

使用关键图像颞骨高分辨率计算机断层扫描鉴别胆脂瘤和慢性中耳炎的多模态大语言模型的诊断性能和短间隔可重复性。
目的:本研究旨在评估多模态大语言模型(LLMs)能否在代表性关键图像颞骨高分辨率计算机断层扫描(HRCT)上区分胆脂瘤和非胆脂瘤性慢性中耳炎(COM),并评估其输出的短间隔可重复性。方法:本回顾性单中心研究(2019-2024)纳入101例接受手术治疗的患者(48例为胆脂瘤,53例为非胆脂瘤性COM)。参照标准为胆脂瘤术中经组织病理学证实的诊断和COM的手术记录。对于每个病例,通过四年级放射科住院医师和委员会认证的头颈放射科医师之间的共识,选择六张反映标准诊断标准的匿名代表性HRCT图像,他们都不知道诊断。随后,GPT-5和Gemini 2.5 Pro llm通过其官方网络界面分析相同的图像,利用结构化提示和零射击方法。这些评估分为两个不同的阶段(S1和S2),间隔1周。主要终点为准确的二元分类。准确性、敏感性、特异性、阳性预测值和阴性预测值均以95%置信区间(ci)计算;采用Cohen kappa (κ)系数评价模型与参考标准的一致性;用McNemar试验评估分类差异。结果:放射科医师的准确率为96.0% (95% CI: 90.3-98.4),与参考标准几乎完全一致(κ: 0.921)。在S1中,GPT-5和Gemini 2.5 Pro的准确率分别为43.6%和49.5%,在S2中分别为46.5%和47.5%。两种模型均具有高灵敏度(83.3% ~ 97.9%)和低特异性(1.9% ~ 13.2%),平衡准确率在0.45 ~ 0.52之间。GPT-5的会话间再现性一般(κ: 0.360), Gemini 2.5 Pro的会话间再现性中等(κ: 0.485),两个会话的模型间一致性轻微(κ: 0.035在S1和κ: 0.086在S2)。两种模型的准确率无显著差异(P = 0.211)。结论:在这项单中心研究中,在评估的版本中,GPT-5和Gemini 2.5 Pro结合了高灵敏度和低特异性,并且在颞骨关键图像HRCT上仅表现出公平至中等的重复性,并且在模型间表现出轻微的一致性。这些发现不支持它们作为独立的第二阅读器使用,并且更广泛地推广到其他多模态llm需要对其他模型进行评估。临床意义:所评估的模型缺乏准确评估复杂中耳结构所需的空间精度和一致性。这一发现强调了由放射科医生进行验证和持续监测的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Diagnostic and interventional radiology
Diagnostic and interventional radiology Medicine-Radiology, Nuclear Medicine and Imaging
自引率
4.80%
发文量
0
期刊介绍: Diagnostic and Interventional Radiology (Diagn Interv Radiol) is the open access, online-only official publication of Turkish Society of Radiology. It is published bimonthly and the journal’s publication language is English. The journal is a medium for original articles, reviews, pictorial essays, technical notes related to all fields of diagnostic and interventional radiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书